Description
1. Introduction
The corrugated PVC tube ref. 34035 is the original replacement for the SPENCER NXT series of electronic and automatic ventilators, reference equipment in emergency services, ambulances, civil protection and assisted transport units. It is an essential consumable of the patient circuit: replacing the tube periodically and with the original part guarantees the airtightness of the circuit, a stable flow and maximum safety during emergency assisted ventilation and medical transport.
2. Technical Explanation
The corrugated tube constitutes the conduit that carries the gas mixture from the ventilator to the patient’s airway. Its corrugated PVC design provides high flexibility and resistance to crushing and kinking, so that the flow path is maintained even during patient or equipment movement, minimising circuit pressure losses. It is the replacement part for the original patient circuit of the SPENCER electronic ventilators of the NXT series and must always be selected according to the exact model and code of the equipment in use.
3. Technical Specifications
The replacement corrugated tube ref. 34035 is indicated for SPENCER ventilators whose equipment codes are detailed below.
Available references (compatible equipment)
| Code | Compatible equipment |
|---|---|
| 34006 | SPENCER 170 NXT electronic ventilator |
| 34007 | SPENCER 170 NXT KOMPAK electronic ventilator |
| 34009 | SPENCER 190 NXT electronic ventilator |
| 34016 | SPENCER 118 NXT automatic ventilator |
| 34017 | SPENCER 118 NXT KOMPAK automatic ventilator |
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 34035 |
| Designation | Corrugated PVC tube, replacement for ventilator |
| Material | Corrugated PVC |
| Length | 117 cm |
| Sales unit | 1 unit (1 pc) |
| Device type | Medical device (Medical device) |
| Device class | II A |
| CND | R02010199 |
| EAN | 8023279340358 |
4. Equivalences and Cross-References
Reference 34035 is the distribution code for this spare corrugated tube for SPENCER ventilators. We do not have a table of equivalences validated by the manufacturer that authorises the direct cross-reference of this reference with codes from other suppliers; the replacement must always be selected according to the exact model and code of the SPENCER ventilator in use (170 NXT, 170 NXT KOMPAK, 190 NXT, 118 NXT or 118 NXT KOMPAK). Within the same manufacturer, the tube is related to the patient circuit for the ventilator (valve + corrugated tube) ref. 34036, an element of the same family of consumables for the respiratory circuit. In the event of any replacement or comparison with third-party products, we recommend verifying compatibility, connection type and materials against the manufacturer’s official data sheet before formalising the purchase or tender.
5. Selection tips and variants of interest
To ensure the correct operation of the ventilation system, always select the tube indicated for the exact model of your SPENCER ventilator. Check the equipment reference printed on the device itself or in its technical documentation (34006 for SPENCER 170 NXT, 34007 for 170 NXT KOMPAK, 34009 for SPENCER 190 NXT, 34016 for 118 NXT and 34017 for 118 NXT KOMPAK) and verify compatibility with the replacement before ordering. It is advisable to have spare corrugated tubes to guarantee the continued operability of the equipment in emergency services, ambulances and emergency units, and to periodically check the condition of the conduit, replacing it at any sign of deterioration, obstruction or loss of airtightness. In the Cahnos catalogue you can complete your provision with the patient circuit (ref. 34036) and the rest of consumables and accessories for emergency ventilation and breathing. For large orders you can request a quote: contact our technical-commercial department to confirm availability and quotation.