We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Patient circuit for ventilator (valve + corrugated tube) · Ref. 34036 · Compatible with SPENCER 170 NXT, 170 NXT KOMPAK and 190 NXT ventilators

215,65 €

Patient circuit consisting of valve and corrugated tube, designed as an original replacement (ref. 34036) for SPENCER electronic ventilators. Compatible with the models SPENCER 170 NXT (code 34006), 170 NXT KOMPAK (code 34007) and 190 NXT (code 34009). Medical device kit, sales unit 1 unit. For large orders you can request a quote: contact our technical-commercial department for availability and offer.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM34036

Description

1. Patient circuit for SPENCER electronic ventilators

The patient circuit ref. 34036 is the original replacement consisting of valve and corrugated tube for SPENCER electronic ventilators. It is an essential component within the assisted ventilation system, as it connects the ventilator to the patient’s airway and safely conducts the gas mixture during emergency ventilatory assistance and medical transport.

It is the replacement accessory indicated for the electronic ventilators of the SPENCER NXT series, widely used in emergency services, ambulances, civil protection and assisted transport units. As it is a consumable/replacement for healthcare use, we recommend verifying compatibility with the exact model of your equipment before placing the order.

2. Technical Explanation

The patient circuit for the ventilator consists of a valve that regulates the passage of respiratory flow and a corrugated tube that carries the gas from the ventilator to the patient. The corrugated design of the tube provides flexibility and crush resistance, maintaining the flow even during patient transport or mobilisation, while minimising pressure losses in the circuit.

The integrated valve ensures the correct operation of the ventilator’s inspiratory/expiratory cycle, guaranteeing patient safety during controlled or assisted ventilation. This kit constitutes the natural replacement set for the original patient circuit of the SPENCER 170 NXT and 190 NXT ventilators.

3. Technical Specifications

The patient circuit (valve + corrugated tube) is indicated for SPENCER electronic ventilators whose equipment codes are detailed in the table of available references.

Available references (compatible equipment) Equipment description
Code 34006 SPENCER 170 NXT electronic ventilator
Code 34007 SPENCER 170 NXT KOMPAK electronic ventilator
Code 34009 SPENCER 190 NXT electronic ventilator

Product data

Characteristic Specification
Manufacturer GIMA
Manufacturer reference 34036
Designation Patient circuit (valve + corrugated tube) for SPENCER electronic ventilator
Sales unit 1 unit (1 pc)
Device type Medical devices kit
EAN 8023279340365

4. Equivalences and Cross-References

Reference 34036 is the distribution code for this patient circuit (valve + corrugated tube) for SPENCER electronic ventilators. We do not have a table of equivalences validated by the manufacturer that authorises the direct cross-reference of this reference with codes from other suppliers; the circuit must always be selected according to the exact model and code of the SPENCER ventilator in use (170 NXT, 170 NXT KOMPAK or 190 NXT).

Within the same manufacturer, the circuit is related to the ventilators whose codes appear in the available references above, as well as to the replacement corrugated tube for the ventilator (ref. 34035), an element of the same consumables family. In the event of any substitution or comparison with third-party products, we recommend verifying compatibility, connection type and materials against the manufacturer’s official datasheet before finalising the purchase or tender.

5. Selection tips and variants of interest

To ensure the correct operation of the ventilation system, always select the patient circuit indicated for the exact model of your SPENCER ventilator. Check the equipment reference printed on the device itself or in its technical documentation (34006 for SPENCER 170 NXT, 34007 for 170 NXT KOMPAK and 34009 for SPENCER 190 NXT) and verify compatibility with the replacement circuit before ordering.

It is advisable to have spare patient circuits to ensure the continued operability of the equipment in emergency services, ambulances and emergency units, and to periodically check the condition of the valve and corrugated tube, replacing them at any sign of deterioration, obstruction or loss of airtightness. In the Cahnos catalogue you can complete your provision with the rest of the consumables and accessories for emergency ventilation and breathing. For large orders you can request a quote: contact our technical-commercial department to confirm availability and offer.

Additional information

Manufacturer reference

34036

Product type

Patient circuit for ventilator (valve + corrugated tube)

Compatibility

Electronic ventilators SPENCER 170 NXT (code 34006), SPENCER 170 NXT KOMPAK (code 34007) and SPENCER 190 NXT (code 34009)

Unit of sale

1 unit (1 pc)

Device type

Medical devices kit

EAN

8023279340365

Presentacion

Unit

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityMultilingüe PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Patient circuit for ventilator (valve + corrugated tube) · Ref. 34036 · Compatible with SPENCER 170 NXT, 170 NXT KOMPAK and 190 NXT ventilators”

Your email address will not be published. Required fields are marked *