Description
1. Commercial Introduction
The sterile suction tube for Yankauer cannula is the connecting element that completes the surgical suction circuit: it connects the rigid suction cannula to the vacuum network or the surgical suction unit, maintaining continuous, stable and safe suction throughout the procedure.
With a length of 200 cm and female connector, it is supplied in an individual sterile package, ready for immediate use in the operating theatre, emergency departments, intensive care units, hospitalisation services and ENT clinics. A professional, reliable, single-use solution that guarantees maximum hygiene and avoids the risks associated with re-sterilisation.
2. Technical explanation of the equipment and procedure
The Yankauer cannula is the clinical standard for suctioning blood, secretions and fluids during surgical, post-surgical and emergency procedures. To transmit the vacuum from the generating equipment (central vacuum network or surgical suction unit) to the cannula, a flexible connection tube such as this product is interposed.
Its female connector fits tightly onto the end of the rigid Yankauer-type cannula, while the opposite end connects to the vacuum system via a universal connector. The 200 cm length provides a wide manoeuvring radius around the operating table or the patient, without compromising the tube lumen or the suction flow rate. As it is a sterile and disposable product, it is indicated for use in direct contact with the sterile field during the procedure.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Product type | Sterile suction tube for Yankauer cannula (rigid suction catheter) |
| Manufacturer | Boscarol |
| Connection type | Female connector |
| Length | 200 cm |
| Presentation | Individual sterile packaging |
| Use | Single-use (disposable) |
| Application | Suction of blood, secretions and fluids in medical and surgical procedures |
| Compatibility | Rigid Yankauer-type suction cannulas and vacuum systems with universal connector |
| Classification | Medical device with CE marking |
Available references
| Reference | Description |
|---|---|
| PA080220 | Sterile suction tube for Yankauer cannula, female connector, 200 cm (manufacturer’s reference) |
| BRLPA080220 | Sterile suction tube for Yankauer cannula, female connector, 200 cm (Cahnos reference) |
4. Equivalences and Cross-References
There is no 1:1 equivalence table validated by the manufacturer for this reference. However, within the Cahnos catalogue there are sterile suction tubes of the same functional category (connection of suction cannulas and surgical suction units via universal connector) that can be used as a reference in approval processes, after technical verification of diameter, connector and presentation:
| Reference | Description | Relationship level |
|---|---|---|
| ORNEX610 (Medline) | Sterile suction tube Ø 6 mm × 3 m, with universal connection ends | Comparable by category |
| ORNEX66A (Medline) | Sterile suction tube Ø 6 mm × 1.8 m | Comparable by category |
| ORNEX510 (Medline) | Sterile suction tube Ø 5 mm × 3 m | Comparable by category |
| ORNEX56A (Medline) | Sterile suction tube Ø 5 mm × 1.8 m | Comparable by category |
These alternatives share function and connection type, but the internal diameter, connector type (male/female) and presentation must be verified before any substitution. Consult the technical-commercial department of Cahnos to confirm compatibility with your suction system.
5. Selection tips and variants of interest
Compatibility: always check the connector type of your Yankauer cannula and your suction unit or vacuum outlet; this tube features a female connector and ends compatible with universal connection systems.
Length: the 200 cm of this tube offer an optimal manoeuvring radius around the operating table; if you require a longer or shorter reach, consider other lengths available in the suction tube catalogue.
Sterility: being sterile and single-use, it is suitable for direct contact with the sterile field during the procedure; for the external suction circuit, non-sterile tubing or replacement rolls may be used.
Vacuum control: if the procedure requires frequent interruption or modulation of suction, consider combining it with Yankauer cannulas with integrated switch or tubes with MED-STOP type vacuum control.
Replacement: the individual sterile package format facilitates stock replenishment in operating theatres, emergency departments, ICUs and ENT services. For B2B volume conditions, contact the commercial team at Cahnos.





Reviews