Description
1. Commercial Introduction
Complete your resuscitation equipment with the adapter for PEEP valve (ref. 34228), a small but essential accessory for making the most of positive end-expiratory pressure ventilation in your manual resuscitators. Manufactured and distributed by Cahnos, this adapter is the manufacturer’s official solution for connecting the 30 mm PEEP valve (ref. 34227) to the equipment, ensuring exact compatibility, airtightness and rapid assembly in emergency situations.
2. Technical explanation
In resuscitation with a self-inflating bag, the PEEP valve maintains a residual positive pressure in the airway at the end of expiration, which promotes alveolar recruitment and improves oxygenation in patients with respiratory compromise. To incorporate this function into the circuit, it is necessary to insert an adapter that connects the bag connector to the PEEP valve. This adapter has an internal diameter of 22 mm (standard 22 mm airway connector) and an external diameter of 30 mm, a dimension that matches that of the 30 mm PEEP valve (ref. 34227), thus ensuring a firm coupling that prevents leaks and pressure losses during manual ventilation.
3. Technical Specifications
| Characteristic | Detail |
|---|---|
| Product type | PEEP valve adapter |
| Inner diameter | 22 mm |
| Outer diameter | 30 mm |
| Compatibility | PEEP Valve Ref. 34227 (GM34227) |
| Manufacturer | GIMA |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II A |
| CND | R03020201 |
| GMDN | 36777 |
| EAN | 8023279342284 |
4. Equivalences and Cross-References
This adapter is the official complement of the 30 mm PEEP valve (ref. 34227 / GM34227), a valve that the manufacturer indicates for codes Ref. 34244, 34245, 34230, 34240, 34200 and 34277 (the latter expressly requires adapter 34228). The manual ventilation family is completed by the single-use PVC resuscitators (refs. 34239, 34248, 34249 and 34277), the rear intake valve (ref. 34256), the autoclavable non-rebreathing valve (ref. 34259) and the oxygen reservoirs (refs. 34257, 34258 and 34275). No validated 1:1 equivalence with adapters from other manufacturers has been found in reliable sources; any substitution must be verified against the corresponding manufacturer’s technical data sheet.
5. Selection tips and variants of interest
Always verify the reference of your equipment: this adapter is designed to connect the PEEP valve 34227 to the indicated resuscitators. Before each commissioning, check the integrity of the adapter and that the fit of the 22 mm connector and the 30 mm valve is firm to avoid pressure losses. If you need to renew or expand your CPR equipment, consider the PEEP valve 34227 and the resuscitator bags of the series (34239, 34248, 34249 and 34277) together with their reservoirs and replacement valves. For large orders you can request a quote: contact the technical-commercial department of Cahnos for availability, volume conditions and delivery times.