The adult Thomas Holder (ref. 05-1650) is an endotracheal tube holder designed to protect and stabilise the adult patient’s airway during intubation. This locking system ensures firm tube fixation, preventing displacement and injury to oral tissues. A practical and safe solution for emergency departments, intensive care units, operating theatres and patient transport. For large orders you can request a quote.
2. Technical explanation of the equipment
The Thomas Holder fixation device acts as an endotracheal tube blocking system (safety endotracheal tubes blocking system). It incorporates a screw fixation system that integrates an anti-tightening protective surface, called no-lockjaw, which has a dual function: on the one hand it protects the patient’s teeth and gums and, on the other, it prevents crushing or occlusion of the endotracheal tube during tightening.
This design allows the tube to be secured safely and stably without the need for surgical tape, plaster or other dressings, which speeds up the procedure, keeps the perioral facial area clean and facilitates inspection and cleaning of the oral cavity without dismantling the fixation. It is indicated for adult patients, where firm tube fixation and protection of oral tissues are critical during prolonged intubations or transfers.
3. Technical Specifications
| Parameter | Specification |
| Product | Adult endotracheal tube holder – Thomas Holder |
| Manufacturer | Boscarol |
| Manufacturer reference | 05-1650 |
| Reference Cahnos | BRL05-1650 |
| Main function | Endotracheal tube blocking system (safety endotracheal tubes blocking system) |
| Fixation system | Screw mechanism |
| Protection surface | Anti-squeeze (no-lockjaw): protects teeth and gums and prevents crushing of the endotracheal tube |
| Additional fixation | Does not require the use of plaster or surgical tape |
| Target population | Adult |
| Category | Respiration and emergency |
4. Equivalences and Cross-References
The original manufacturer’s reference is 05-1650, distributed by Cahnos as BRL05-1650 within the resuscitation equipment range. In the same Cahnos catalogue there is the paediatric version of this holder, reference BRL05-1651 (manufacturer’s ref. 05-1651), designed for the paediatric airway; before adding either one to your inventory, verify that the holder size corresponds to the endotracheal tube diameter and the patient’s anatomy.
No validated 1:1 equivalence table with other manufacturers is available from reliable sources for this holder: endotracheal tube anchoring systems (ties, bite-block fixators, mouth guards) are manufacturer-specific and must always be checked against the official technical data sheet before any substitution. To confirm compatibility with your intubation protocol, contact the technical-commercial department at Cahnos.
5. Selection tips and variants of interest
Verify that the reference corresponds to the adult version of the Thomas Holder (05-1650) before adding it to your airway equipment: the holder sizing must match the endotracheal tube diameter and the oral anatomy of the adult patient. Confirm the progressive tightening of the screw mechanism until a firm hold is achieved without occluding the tube, using the anti-tightening surface that protects the tissues.
Remember that this system avoids the use of plaster, which facilitates hygiene and maintenance of the oral cavity during prolonged intubations. For institutional orders, tenders and purchasing groups, consult the Cahnos team.