Description
1. Product Presentation
The roll of thermal paper for the Siemens SICARD 440 electrocardiograph is the recording consumable that ensures clear, stable and archivable tracings on the SICARD 440 series equipment. Its roll format of 148 mm wide by 25 metres long with a red grid is designed for continuous capture of electrocardiographic recordings in cardiology clinics, emergency departments, occupational medicine and diagnostic units.
Marketed under the reference Cahnos 0553122, it reproduces the construction of the original factory consumable 6934400 E100E (also documented as 93.90.717 / 9390717), so it can be used as a direct replacement for the original paper. It is supplied in a box of 20 units with immediate dispatch (24-72 h), as a replacement solution that ensures the continuity of care for your service.
2. Technical explanation of the equipment and procedure
The Siemens SICARD 440 electrocardiograph records the electrical activity of the heart using a direct thermal printing system: the image is generated by contact of the hot print head on the heat-sensitive layer of the paper, without the need for ink, toner or ribbon. The quality of the tracing therefore depends on the thermal sensitivity of the paper, its grammage and the correct orientation of the roll when loading it into the equipment.
The pre-printed red grid allows the clinician to accurately measure amplitudes (mV), intervals (PR, QT, RR) and recording speeds (mm/s) directly on the paper, while the print head prints the patient’s signal and identification data on each tracing. The use of verified quality paper prevents jams, ghost prints and premature fading of the image in the clinical record.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Compatible equipment model | Siemens SICARD 440 (electrocardiograph with thermal recorder) |
| Manufacturer OEM reference | 6934400 / E100E · also documented as 93.90.717 (9390717) |
| Factory reference (master catalogue) | 10.148.01 (LESSA / AB Medica Group) |
| SKU / Commercial reference Cahnos | 0553122 · line code 9356 (internal, not manufacturer code) |
| Roll dimensions | 148 mm × 25 m |
| Format | Thermal paper roll |
| Grid colour | Red |
| Print technology | Direct thermal printhead (no ink, toner or ribbon) |
| Commercial presentation | Box of 20 units (rolls) |
| Application | Electrocardiographic (ECG) and medical recording on equipment with a thermal printhead compatible with its grammage |
| Classification | Class I medical device (recording paper with measuring function) · CE · R.D. 1591/2009 · Directives 93/42/EEC and 2007/47/EC |
| Trace preservation | Approx. 5 years after printing, under normal archival conditions |
| Recommended storage | Cool, dry place, 5 °C – 40 °C, protected from direct sunlight |
4. Equivalences and Cross-References
The OEM reference 6934400 for the Siemens SICARD 440 paper is consistently documented by European manufacturers and distributors of medical recording paper (Diagramm Halbach, wefi-medical, medical-praxisbedarf, ka-med), with a roll format of 148 mm × 25 m. The following equivalences should be understood as functional comparisons confirmed in manufacturer and authorised distribution catalogues, not as an official equivalence table published by the equipment manufacturer.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Siemens Healthineers (original code) | ECG recording paper SICARD 440 · 148 mm × 25 m · red grid | 6934400 E100E · also documented as 93.90.717 (9390717) | Exact reference equivalence (original manufacturer code) | OEM code confirmed in authorised distribution sources (wefi-medical: Original-Nr. 6934400; medical-praxisbedarf: 9390717); same dimensions and red grid. Verify presentation and batch against the box of 20 units of this reference. |
| Diagramm Halbach GmbH & Co. KG (Germany) | ECG paper Siemens Sicard 440 · 148 mm × 25 m | HTN 711870 · Best.-Nr. 140030 | Comparable by category (not interchangeable 1:1) | Same dimensions (148 mm × 25 m) and same target equipment. Grid colour of the batch to be verified against the red grid of this reference; confirm grammage and thermal sensitivity against the equipment data sheet. |
| LESSA / AB Medica Group (Spain) | Siemens SICARD-440 recording paper · 148 × 25 · red grid | 10.148.01 (master catalogue; OEM 93.90.717 E100E) | Comparable by category (not interchangeable 1:1) | The master catalogue documents this reference with dimensions 148 × 25 and red colour (matching). Verify grammage and archival legibility against the equipment data sheet. |
There is no equivalence table validated by the equipment manufacturer for this reference; consult the technical department before use in tenders. The code 9356 accompanying the reference is an internal distribution line code and must not be used as a manufacturer code: the code identifying the consumable is the OEM 6934400 (E100E), confirmed in authorised distribution sources, together with its documented equivalent 93.90.717 (9390717).
5. Selection tips and variants of interest
Select this roll when your service uses a Siemens SICARD 440 electrocardiograph: always check the paper width (148 mm), length (25 m), grid colour (red) and the roll core diameter before replacing the consumable; an inappropriate grid or grammage can affect the legibility of the recording and the wear of the thermal print head.
Within the Siemens family of the catalogue, Cahnos offers other variants of the same line: the pad for SICARD 460 of 148 × 100 mm with 400 sheets and orange grid (ref. 0553113), the pad for CARDIOSTAT 3 of 144 × 150 mm with 400 sheets (ref. 0992957), the pad for CARDIOSTAT 31/31S of 104 × 100 mm with 300 sheets and red grid (ref. 0553078) or the roll for Burdick EK 10 of 50 mm × 30 m (ref. 0553042). The same OEM construction 93.90.717 is also documented in the master catalogue under the distribution reference 0992969; confirm availability with our department before ordering it.
Store the paper in a cool, dry place (5 °C – 40 °C), protected from direct sunlight and heat sources, to preserve the stability of the tracing and avoid fogging of the heat-sensitive layer. Recording shelf life: approximately 5 years under suitable archiving conditions.