Description
1. Commercial Introduction
The thermal paper roll for the Siemens Theracard PM (reference Cahnos 0553055-SM) is the recording consumable that keeps the recorder/defibrillator of this family operational. Its 50 mm × 30 m format with red grid ensures clear, stable and perfectly measurable traces, both in electrocardiographic recording and in monitoring in emergency departments, cardiology clinics and diagnostic centres.
The presentation in a box of 20 units allows planned and cost-effective replenishment, avoiding service interruptions due to lack of consumable. Available with delivery in 24-72 h; request a formal quotation for institutional orders, maintenance contracts and tenders.
2. Technical Explanation
This roll uses direct thermal printing technology: the equipment’s thermal head transfers heat to the paper’s heat-sensitive layer and generates the trace instantly, without the need for ink, toner or ribbon. This reduces recorder maintenance and speeds up the output of the clinical document. The high-sensitivity thermal paper is sized to the grammage required by the equipment, ensuring a trace with no blank areas or saturation.
The pre-printed red grid acts as a measurement reference (recording graph paper): it allows the amplitude of the waves (mV), the duration of the intervals (time) and the recording speeds (mm/s) to be assessed, facilitating the clinical interpretation of the electrocardiogram and of the events recorded by the defibrillator.
3. Technical Specifications
| Compatible equipment model | Siemens Theracard PM (defibrillator/recorder with thermal printhead printing) |
| SKU / Reference Cahnos | 0553055-SM |
| Line code (accompanies the reference) | 10302 (internal distribution code; must not be used as a manufacturer code) |
| Roll dimensions | 50 mm × 30 m |
| Core inner diameter | 16 mm (standard in the 50×30 range for this type of paper; check the batch label) |
| Format | Thermal paper roll |
| Grid colour | Red |
| Paper type | High-sensitivity thermal heat-sensitive paper |
| Print technology | Direct thermal printhead (no ink, toner or ribbon) |
| Commercial presentation | Box of 20 units |
| Application | Medical recording (electrocardiograms, monitoring and defibrillation events) in equipment with a thermal head suitable for its grammage |
| Regulatory classification | Medical device Class I (recording paper with measuring function) · CE · R.D. 1591/2009 · Directives 93/42/EEC and 2007/47/EC |
| Trace shelf life | Approx. 5 years after printing under proper storage conditions |
| Storage | Cool, dry place, 5 °C – 40 °C, protected from direct sunlight and heat sources |
4. Equivalences and Cross-References
Preliminary note: there is no equivalence table validated by the equipment manufacturer (Siemens) that authorises third-party consumables for the Theracard PM. The following references correspond to the same category (ECG thermal paper roll 50 mm × 30 m with grid) and have been cross-checked in public catalogues of their respective manufacturers or distributors, with the indicated levels of equivalence. Before substituting in a tender, verify one by one the width, core diameter, grid colour and grammage.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| LESSA / AB Medica Group (Spain) | Thermal paper 50×30 red grid for Siemens Cardiostat-1 (OEM 91.07.202) | 10.050.03 (LESSA catalogue 1005003) | Comparable by category (not interchangeable 1:1) | Same dimensions (50 mm × 30 m) and same red grid; confirmed in the manufacturer’s public catalogue. Different target equipment (Cardiostat-1); verify core and grammage of the batch. |
| Neotecnia (NT) | 1-channel ECG paper, 5 cm × 30 m, red grid (NT range, distribution) | NT-1005003 / NTX-1005003 | Comparable by category (not interchangeable 1:1) | Same dimension 50 mm × 30 m and red grid; manufactured for single-channel electrocardiographs of different brands. Confirm thermal sensitivity and grammage against the equipment’s data sheet. |
| Diagramma AG (Switzerland, specialised distribution) | EKG-Papier Theracard PM (Siemens) | 0110011.001 (declared original Siemens P/N: 45 23 122 EH 400) | Comparable by category (not interchangeable 1:1) | Reference declared by a specialised distributor for this same equipment model; supplied in individual units as opposed to the box of 20 of this reference. Verify measurements, grid colour and grammage of the batch. |
There is no equivalence table validated by the manufacturer; consult the technical department before using in a tender. The code 10302 accompanying this reference is an internal distribution line code and must not be used as the original code of the equipment manufacturer. Within the Cahnos catalogue itself, the same physical format 50 mm × 30 m is also supplied under references 0553055-CL (Cardioline E 1 / ETA 150, red grid) and 0553055-EB (Esaote Biomedica C1-P, orange grid): they share packaging and dimensions, but the equipment and grid colour must be verified before any substitution, as they are not interchangeable 1:1 without that check.
5. Selection tips and variants of interest
Verify the exact model of your equipment: this reference is designed for the Siemens Theracard PM recorder/defibrillator. Always check the roll width (50 mm), length (30 m), inner core diameter and grid colour (red) before replacing the consumable; an inappropriate grid or grammage can affect the legibility of the recording and the wear of the thermal head.
Do not confuse the roll with a Z-fold pad: if your recorder prints on a pad, select the corresponding pad reference from the Siemens family. Variants of the same family in Cahnos: roll for Siemens Burdick EK 10 of 50 mm × 30 m (ref. 0553042), roll for SICARD 440 of 148 mm × 25 m with red grid (ref. 0553122), pad for CardioStat 31/31S of 104 × 100 mm with 300 sheets (ref. 0553078) or SICARD 460 pad of 148 × 100 mm with 400 sheets and orange grid (ref. 0553113).
Store the paper in a cool, dry place (5 °C – 40 °C), protected from direct sunlight and heat sources, to preserve the sensitivity of the thermal layer and the stability of the trace in the clinical archive. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and formal quotation.




Reviews