Description
1. Commercial Introduction
The ECG thermal paper block for Schiller CARDIOVIT AT-4 / AT-104 (reference Cahnos 0553121) is the recording consumable that keeps your electrocardiograph operational in cardiology clinics, emergency departments, occupational medicine and diagnostic centres. Its Z-fold format of 90 × 90 mm, with 266 sheets per block and red grid, guarantees clear, stable and perfectly measurable traces in every examination, both in resting ECG and stress tests.
The presentation in a box of 20 blocks allows planned and cost-effective replenishment, avoiding service interruptions due to lack of consumables. Manufacturer (OEM) references: 2,157,016 / 290018. Available with delivery in 24-72 h; request a formal quotation for institutional orders, maintenance contracts and tenders.
2. Technical Explanation
This block uses direct thermal printing technology: the thermal head of the electrocardiograph transfers heat to the thermosensitive layer of the paper and generates the trace without the need for ink, toner or ribbon, which reduces equipment maintenance. The high-sensitivity thermal paper is dimensioned to the grammage required by the recorder, ensuring a trace without blank areas or saturation.
The pre-printed red grid acts as a measurement reference (millimetre recording paper): it allows assessment of wave amplitude (mV), interval duration (time) and recording speeds (mm/s), facilitating clinical interpretation. The block includes an automation marker (black square) so that the equipment synchronises events and annotations on the recording, and is presented in Z-fold (fanfold) with a multi-perforated easy-tear separator, a format that facilitates continuous feeding, prevents jams and allows subsequent filing of the clinical document.
Main applications: resting and stress electrocardiograms (ECG), stress tests and ergometry, and other medical recordings with thermal head printing suitable for its grammage.
3. Technical Specifications
| Characteristic | Technical data |
| Reference Cahnos (SKU) | 0553121 |
| Equipment model | Schiller CARDIOVIT AT-4 / AT-104 (AT-104 PC in distribution) |
| Manufacturer (OEM) references | 2,157,016 / 290018 (package numbering updated in distribution: 2,157,052 for AT-104 PC) |
| Sheet dimensions | 90 mm × 90 mm |
| Number of sheets | 266 per block |
| Equivalent length | ≈ 23.9 m per block (calculated distribution data) |
| Grid colour | Red |
| Automation marker | Yes (black square; check batch) |
| Format | Z-fold paper pad (fanfold) |
| Paper type | High-sensitivity thermal |
| Print technology | Direct thermal printhead (no ink, toner or ribbon) |
| Commercial presentation | Box of 20 blocks |
| Regulatory classification | Medical device Class I (with measuring function) · R.D. 1591/2009 · CE |
| Trace shelf life | 5 years after printing (refer to the product instructions) |
| Storage | 5 °C to 40 °C, cool and dry place, without direct sunlight or excess humidity |
4. Equivalences and Cross-References
Preliminary note: there is no equivalence table validated by the manufacturer (Schiller) that authorises third-party consumables for this block. The OEM references associated with this product are 2,157,016 / 290018 (CARDIOVIT AT-4 / AT-104), consistently confirmed in authorised distribution catalogues and by recording paper manufacturers. References from other brands belong to the same category (Z-fold ECG thermal paper of 90 × 90 mm) and have been cross-checked in public sources from their respective manufacturers or authorised distributors. Before substituting in a tender, verify one by one the number of sheets, grid colour and automation marker.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Schiller (same manufacturer) | CARDIOVIT AT-4 / AT-104 (OEM paper reproduced by this block) | 2,157,016 · 290018 · 2,157,016C (box of 25 packs) | Exact reference equivalence (same manufacturer) | OEM references of the product itself: 90 × 90 mm × 266 sheets, red grid, Z-fold. Confirmed in authorised distribution catalogues; the original box 2,157,016C contains 25 packs (compared to 20 of this reference). |
| Quality Chart Paper (USA) | Z-fold ECG thermal paper for Schiller AT-4 / AT-104 | SH9090P3A1 | Comparable by category (not interchangeable 1:1) | Confirmed on the manufacturer’s website: 90×90 mm, red grid, declared for AT-4 / AT-104 (original code 2157016); 400 sheets per block compared to 266. Verify grammage and sensitivity with the head. |
| Beck-Lee (US distributor) | Schiller Z-Fold EKG Chart Paper (2.157016) for AT-4 / AT-104 | 2157-016C | Comparable by category (not interchangeable 1:1) | Confirmed on the manufacturer’s website: red grid, 89×89 mm (3.5″ × 3.5″), 255 sheets per pack (compared to 266) and presentation of 25 packs per box. Same practical dimensions; verify sheet count of the batch. |
| Nissha Medical / Welch Allyn (USA) | Schiller EKG Paper SC2157-016A for AT-4 | SC2157-016A | Comparable by category (not interchangeable 1:1) | Confirmed in authorised distribution catalogue (Probo Medical / Davis Medical): z-fold, red grid, 90×90 mm, 400 sheets per pack and boxes of 50. More sheets per pack; verify compartment compatibility and grammage. |
| EasyTrace® (Deas S.r.l., Italy) | Z-fold ECG packs for Schiller AT-1 / AT-4 | SH9090P | Comparable by category (not interchangeable 1:1) | Confirmed in manufacturer distribution lists: format 90×90 mm, 200 sheets per pack (compared to 266). Verify grid colour and batch marker before substituting. |
| Ribas Medicina (authorised distributor) | ECG Paper Block 090×090×200 for Schiller AT-4 | 6109002 | Comparable by category (not interchangeable 1:1) | Confirmed in distributor catalogue: 90×90 mm, 200 sheets, red grid and automation marker (black square), declared OEM 2,157,016. Differs in number of sheets (200 compared to 266). |
| LUMEDlink (Doctorshop / Gima distribution line) | Compatible ECG thermal paper Schiller 90 × 90 mm | CFSC008 (code 106061) | Comparable by category (not interchangeable 1:1) | Confirmed on the manufacturer’s website: 90×90 mm, 390 sheets and indicator yes, but green grid (not red) and declared for AT-1 / AT-4. Not interchangeable without prior verification of the grid colour required by the equipment. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. The OEM reference associated with this pad is 2,157,016 / 290018 (Schiller CARDIOVIT AT-4 / AT-104), with updated package numbering 2,157,052 cited in distribution for AT-104 PC. The same physical 90×90 format is distributed on the market with 200, 255, 266 or 400 sheets depending on the batch and paper manufacturer, as well as with a red or green grid; always check the grid colour, number of sheets and presentation per box before a substitution.
5. Selection tips and variants of interest
Check the exact model of your device: this pad is designed for Schiller CARDIOVIT AT-4 / AT-104 (90×90×266 sheets, red grid). Do not confuse it with the pad for AT-1 / Spirovit SP-1 (ref. 2,157,014 / 290017, 90×90×400 sheets, ref. Cahnos 0553059), which shares the same dimensions but differs in the number of sheets and device calibration.
Grid and marker colour: the AT-4 / AT-104 device uses paper with a red grid and automatic marker (black box). Versions of the same format with a green or orange grid (e.g. LUMEDlink CFSC008) are not interchangeable without prior verification on each device.
Do not confuse pad with roll: if your recorder prints on a roll, select the corresponding roll reference from our family of thermal papers for Schiller devices instead of this pad.
Variants of the same family at Cahnos (Schiller papers): 0553059 (AT-1 / SP-1, 90×90×400), 0553045 (AT-3, 70×100×200), 0553023 (AT-10 E, 210×140×250), 0553119 (AT-10 PLUS / AT-110, 210×140×160), 0553167 (AT-6 / AT-6 M, 145×100×350), 0553077 (AT-10 / AT-60 / CS 100, 210×280×360), 0553168-S (AT-2 / CS 200), 0553178-S (AT-102) and 0992026-S (AT-101 / Defigard).
Storage: keep the pad in a cool, dry place away from direct sunlight, at a stable temperature between 5 °C and 40 °C, to preserve the quality of the trace and prevent fogging of the thermal layer during the 5-year retention period of the clinical record.





Reviews
There are no reviews yet.