Description
1. Commercial Introduction
The ECG thermal paper block for Quinton (ref. Cahnos 0553029) is the recording consumable that keeps your electrocardiographs and Q-series stress test systems operational in cardiology clinics, emergency departments, occupational medicine and diagnostic centres. Its Z-fold format of 216 × 280 mm, with 200 sheets per block and orange reference grid, guarantees clear, stable and perfectly measurable traces in every examination, both in resting ECG and during ergometry.
The presentation in a box of 10 blocks allows planned and cost-effective replenishment, avoiding service interruptions due to lack of consumables. It reproduces the construction of the original paper for Quinton equipment (factory references 18416-001 / 18416-002). Available with delivery in 24-72 h; request a formal quotation for institutional orders, maintenance contracts and tenders.
2. Technical explanation of the equipment and procedure
The Quinton Q-series electrocardiographs and stress test systems (Q750, Q4500 and Q5000) record the electrical activity of the heart using a direct thermal printing system: the hot print head transfers heat to the heat-sensitive layer of the paper and generates the trace instantly, without the need for ink, toner or ribbon. This reduces equipment maintenance and maintains consistent print quality throughout the entire block.
The pre-printed grid acts as a millimetric reference on the paper: it allows assessment of wave amplitude (mV), interval duration (PR, QT, RR) and recording speeds (mm/s), facilitating clinical interpretation of the electrocardiogram and stress test curves. The Z-fold (fanfold) format feeds the sheets continuously, prevents jams and facilitates subsequent filing of the record in the clinical history. The quality of the recording depends on the thermal sensitivity of the paper, its grammage and correct loading of the block: verified quality paper avoids ghost prints and premature fading of the trace, whose durability is approximately 5 years under normal archiving conditions.
3. Technical Specifications
Main features of the thermal paper pad for Quinton Q750 / Q4500 / Q5000:
| Characteristic | Specification |
| Brand / equipment family | Quinton (Q-series electrocardiographs and stress test systems) |
| Compatible models | Q750 / Q4500 / Q5000 |
| Reference Cahnos (SKU) | 0553029 (line 11820) |
| Manufacturer (OEM) references | 18416-001 / 18416-002 |
| Sheet dimensions | 216 mm × 280 mm (8.5″ × 11″ format) |
| Number of sheets | 200 per pad (the same line is supplied in some batches with 218 sheets; check label) |
| Format | Z-fold thermal paper (fanfold) |
| Grid colour | Orange (depending on supply line; on the market, code 18416-001 is also distributed with a red grid) |
| Paper type | High-sensitivity thermal paper |
| Print technology | Direct thermal printhead (no ink, toner or ribbon) |
| Commercial presentation | Box of 10 blocks |
| Application | Medical recording: resting and stress electrocardiograms (ECG), stress tests and ergometry, on equipment with thermal head printing suitable for its grammage. |
| Regulatory classification | Class I medical device (with measuring function) · R.D. 1591/2009 · Directives 93/42/EEC and 2007/47/EC · CE marking |
| Trace shelf life | Approx. 5 years after printing under proper storage conditions |
| Storage | 5 °C – 40 °C, cool and dry place, without direct sunlight or excessive humidity |
4. Equivalences and Cross-References
Preliminary note: there is no equivalence table validated by the manufacturer of Quinton equipment (Cardiac Science) that authorises third-party consumables for this reference. The OEM code associated with this block is 18416-001 / 18416-002, and in US distribution it is also documented as 036869-001 (Q-Stress / Q-Series family, with double tail marks or queue marks). The references from other brands indicated belong to the same category (Z-fold ECG thermal paper 216 × 280 mm for head recorders) and have been verified in manufacturer or authorised distribution catalogues. Before substituting in a tender, verify one by one the number of sheets, the grid colour and the presence of synchronisation marks.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Leonhard Lang (Skintact) / S&W Healthcare | Quinton ECG recording paper, Z-fold, red grid, double tail mark | 14062 | Comparable by category (not interchangeable 1:1) | Confirmed in manufacturer catalogue and authorised distribution (CNA Medical, apharx): 216 × 280 mm, 200-218 sheets per block, 10 blocks/box; declared equivalent to Quinton 036869-001 / 11820-2Q for Q-Stress and Q3000 with stress tape. Red grid versus the orange of this line: verify colour before substituting. |
| Graphic Controls Industrial | Quinton thermal recording paper, Z-fold, red grid | 7G30729225 | Comparable by category (not interchangeable 1:1) | Confirmed in authorised distribution (CIAMedical, ProMedical Store): Z-fold thermal ECG/EEG paper, red grid, 8.5″ × 183′ (~216 mm wide), 20 blocks per box, declared for Quinton 18416-001. Length/capacity expressed in continuous length: verify sheet equivalence and colour against the batch. |
| Cardinal Health | Z-fold recording paper for Quinton 18416-001 | 3687561 | Comparable by category (not interchangeable 1:1) | Confirmed in authorised distribution (CIAMedical): Z-fold chart paper declared for Quinton 18416-001, presentation by pack and box of 20. Verify sheet and grid colour against this line before substitution. |
| Beck-Lee ECG (distributor) | Quinton Z-Fold EKG Chart Paper, red grid, 216 × 280 mm | 18416-001q | Comparable by category (not interchangeable 1:1) | Confirmed in distributor catalogue: generic paper for Quinton 18416-001, red grid, declared for Q-Stress, Q710, Q750, Q4500 and Q645. Different paper manufacturer and red grid: not interchangeable 1:1 without prior verification of colour and number of sheets. |
There is no equivalence table validated by the equipment manufacturer; consult the technical department before use in a tender. The OEM code associated with this consumable is 18416-001 / 18416-002 (Quinton Q-Series recording family), also documented as 036869-001 in specialised distribution; the reference 11820 accompanying SKU 0553029 is a distribution line code of the catalogue itself and must not be used as a manufacturer code. Always verify the sheet width (216 mm), height (280 mm), number of sheets (200-218 depending on batch), grid colour (in this line, orange) and Z-fold format before formalising a substitution.
5. Selection tips and variants of interest
Verify the exact model of your equipment: this block is designed for Quinton Q750, Q4500 and Q5000 electrocardiographs with a 216 mm wide thermal head recorder. Always confirm the grid colour of your protocol: in this supply line it is orange, while the same OEM code 18416-001 is distributed on the market with a red grid; an inappropriate grid can affect the visual calibration of amplitudes and recording speeds.
Within the Quinton family of the Cahnos catalogue you will find variants of the same range of 216 × 280 mm blocks: the line for Q5000 / Q750 / Q-CATH with reference 16211-002 and flat grid (ref. 11259) and its variant 16211-001 (ref. 11767), both of 200 sheets; the line for Q3000 / Q3000B / Q4000 / Q4000B with reference 15022-001 (ref. 10881), and the line for Q710 with reference 036869-001 (ref. 14062). All share the same equipment family and recording dimensions of 216 × 280 mm but differ in OEM reference, number of sheets or grid colour: they are not interchangeable 1:1 without verifying the printer model.
Storage: store the blocks in a cool, dry place (5 °C – 40 °C), protected from direct sunlight and heat sources, to preserve the sensitivity of the thermal layer and prevent the trace from fogging, ensuring the legibility of the record in the clinical file. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and formal quotation.





Reviews