We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

ECG thermal paper pad Nihon Kohden A/PA-9100Z (PA 9100 Z) 210 x 140 mm, 142 sheets, red grid, Z-fold – Cardiofax Q, ECG-9100, ECG-9110K, ECG-9130K, ECG-1350A | Ref. 0590500

15,25 €

ECG thermal paper pad Nihon Kohden A/PA-9100Z (model PA 9100 Z), Z-fold format of 210 x 140 mm with red grid and 142 sheets, designed for the Cardiofax Q, ECG-9100, ECG-9110K, ECG-9130K and ECG-1350A electrocardiographs. Thermal printhead consumable that ensures a clear, stable and archivable trace in cardiology, emergency, monitoring and stress testing. Ref. 0590500 (official manufacturer designation A/PA-9100Z, verified in GUDID), box of 5 pads with immediate dispatch.

International shipping. Import duties and taxes are payable by the recipient.

Reference
0590500-NK

You will also find it in

Description

Thermal recording paper for Nihon Kohden electrocardiography

The Nihon Kohden A/PA-9100Z thermal paper block (official manufacturer designation for model PA 9100 Z) is the ideal recording consumable for electrocardiographs and recorders of the Cardiofax Q, ECG-9100, ECG-9110K, ECG-9130K and ECG-1350A family. Each block contains 142 heat-sensitive sheets in Z-fold format with red grid, ensuring clear, stable and easily archivable printouts for each clinical record. It is supplied in a box of 5 units and is the continuous replacement solution for cardiology departments, emergency rooms, monitoring units, functional testing rooms and diagnostic equipment maintenance programmes. Available with immediate dispatch for replenishment orders and supply contracts.

Technical product explanation

Nihon Kohden medical recorders use thermal printhead technology: the heat-sensitive paper reacts to the heat generated by the printhead and darkens the traced area without the need for ink or toner. The Z-fold format facilitates continuous paper feeding and clean separation of each sheet after printing, while the pre-printed red grid acts as a measurement reference for interpreting electrocardiogram amplitudes and timings. The paper weight and sensitivity must be compatible with the equipment’s printhead energy; therefore, this consumable is specifically dimensioned for the models of the mentioned series, ensuring a homogeneous trace without blank areas or saturation. To preserve the stability of the record, the block should be stored in a cool, dry place between 5 and 40 °C, avoiding direct sunlight and excessive humidity; the trace maintains its legibility for 5 years after printing if the product’s storage instructions are followed.

Technical specifications

The following specifications correspond to the Nihon Kohden ECG thermal paper block model PA 9100 Z (A/PA-9100Z), commercial reference 0590500-NK.

Characteristic Detail
Model PA 9100 Z (A/PA-9100Z)
Commercial reference 0590500-NK (Ref. 0590500 – 13108)
Official manufacturer designation A/PA-9100Z (verified in GUDID/FDA)
Format Z-fold paper pad
Fanfold dimensions 210 mm x 140 mm
Number of sheets 142 sheets per block
Grid Red, for reading and measuring the trace
Print technology Thermal head (thermal paper, no ink)
Compatibility Nihon Kohden: Cardiofax Q, ECG-9100, ECG-9110K, ECG-9130K, ECG-1350A and PA-9100Z
Presentation Box of 5 blocks
Applications Electrocardiographic recording, stress tests, vital signs monitoring
Storage Between 5 and 40 ºC; avoid direct sunlight and excessive humidity
Trace shelf life 5 years after printing (refer to the product instructions)
Regulatory classification Class I (medical recording paper, with measuring function)

Equivalences and cross-references

The official manufacturer reference for this recording paper is A/PA-9100Z, a designation verified in the GUDID/FDA database (NIHON KOHDEN AMERICA, INC.; UDI 10841983103954). The code 0590500-NK is the internal numbering of the distributor Cahnos; the secondary numbering 13108 is not verifiable in public sources and must be confirmed with the manufacturer before use. There is no official equivalence table validated and published by Nihon Kohden; the third-party references indicated below come from verified independent sources (GUDID, authorised distribution catalogues) and share the format 210 x 140 mm, Z-fold, red grid and 142 sheets, but as they come from other manufacturers they must be labelled as comparable by category: before replacing, check paper weight and sensitivity with the equipment printhead.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Vermed / Graphic Controls ECG recording paper red grid Z-Fold (NKN PA9100Z) 32017003 Comparable by category (not interchangeable 1:1) Code confirmed in GUDID (Vermed / Graphic Controls Acquisition Corp.); same format 210 x 140 mm Z-fold with red grid; check paper weight before replacing.
Precision Charts Thermal EKG paper red grid Z-Fold (for ECG-9100/9110K/9130K/1350A) PA9100Z Comparable by category (not interchangeable 1:1) Thermal paper 210 x 140 mm, Z-fold, red grid and 142 sheets; presentation of 10 blocks per box; check paper weight with the equipment printhead.
Leonhard Lang USA Recording Chart Paper Nihon Kohden PA9100Z PA9100Z Comparable by category (not interchangeable 1:1) Premium paper 210 x 140 mm x 142 sheets with red grid; presentation of 20 blocks per box; confirm paper sensitivity before replacement.
Danlee Medical 9100Z recording paper red grid PNPA9100Z / 7314825 Comparable by category (not interchangeable 1:1) Old numbering PNPA9100Z; replaces Nissha 7G32017349; 142 sheets per block with red grid; declared use in Cardiofax Q and ECG-9100/9110K/9130K.
McKesson Nihon Kohden Z-Fold recording paper red grid 1226762 Comparable by category (not interchangeable 1:1) USA distribution reference associated with A/PA-9100Z; same format and grid; boxes of 10 blocks; check local availability before use.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering.

Selection tips and variants of interest

Before replacing the consumable, check the exact model of the recorder: Cardiofax Q series and ECG-9110K/9130K equipment accept this 210 x 140 mm block, but Cardiofax S (ECG-1250K) or GEM-9010/9020/9022 models require the 110 x 140 mm format. For high-volume orders or maintenance programmes, the 214-sheet variant (Ref. 0553034, FQS 210-3-140) or the 200-sheet block for Cardiofax M ECG-1350K (Ref. 0553056, FQW 210-3-140) may be considered; if the recorder accepts roll, the RQS 210-3 option (Ref. 0553179) is available. Always store the blocks in a cool, dry place away from direct sunlight and heat sources, to preserve the thermal paper sensitivity and trace stability for 5 years after printing.

Additional information

Model

PA 9100 Z (A/PA-9100Z)

Reference

0590500-NK

Format

Z-fold paper pad

Measurements

210 x 140 mm

Grid colour

Red

Print technology

Thermal printhead (thermal paper)

Compatibility

Nihon Kohden: Cardiofax Q, ECG-9100, ECG-9110K, ECG-9130K, ECG-1350A

Presentation

Box of 5 blocks

Storage

Between 5 and 40 ºC; avoid direct sunlight and excessive humidity

Regulatory classification

Class I (medical recording paper, with measuring function)

Commercial reference

0590500-NK (Ref. 0590500)

Manufacturer reference

A/PA-9100Z (verified in GUDID/FDA)

Number of sheets

142 sheets per block

Grid

Red, for reading and measuring the trace

Printing technology

Thermal head (thermal paper, no ink)

Trace shelf life

5 years after printing

Reviews

There are no reviews yet.

Be the first to review “ECG thermal paper pad Nihon Kohden A/PA-9100Z (PA 9100 Z) 210 x 140 mm, 142 sheets, red grid, Z-fold – Cardiofax Q, ECG-9100, ECG-9110K, ECG-9130K, ECG-1350A | Ref. 0590500”

Your email address will not be published. Required fields are marked *