We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

ECG Thermal Paper Roll Fukuda Denshi OP-119TE / OP-119TEC · 63 mm × 30 m · Orange Grid · Cardimax FCP-2101U / FCP-7101 / FCP-7102 · Box of 10 Rolls · Ref. 0553110

26,40 €

Roll of ECG thermal paper Fukuda Denshi with OEM reference OP-119TE / OP-119TEC, in 63 mm × 30 m format with a high-sensitivity orange grid. Recording consumable for the Cardimax FCP-2101U, FCP-7101 and FCP-7102 electrocardiographs, also commonly used in FCP-15, FCP-2101, FX-2111, FCP-2155, FCP-2201, FX-7101, FX-7102 and FCP-8100 of the same format. Direct thermal printing via head, without ink or toner: sharp, stable traces with millimetric reading, with a recording shelf life of 5 years under suitable storage conditions. Supplied in a box of 10 rolls with immediate dispatch. Ref. Cahnos 0553110.

International shipping. Import duties and taxes are payable by the recipient.

Reference
0553110

Description

1. Product Presentation

The thermal paper roll Fukuda Denshi (ref. Cahnos 0553110) is the reference recording consumable for the Cardimax electrocardiographs from the Japanese company most widely used in cardiology, emergency and general practice clinics. Its 63 mm × 30 m with orange grid format guarantees clear, stable and perfectly measurable traces in every examination, both in resting ECG and in stress tests. It is supplied in a box of 10 rolls, the replacement that ensures continuity of care and avoids service interruptions due to lack of paper. Immediate dispatch 24-72 h and formalised quotation for institutional purchases and tenders.

2. Technical Explanation

This roll uses direct thermal printing technology: the electrocardiograph’s thermal head transfers heat to the paper’s thermosensitive layer and produces the trace instantly, without the need for ink, toner or ribbon, which reduces recorder maintenance and maintains consistent print quality throughout the entire roll. The OEM reference OP-119TE / OP-119TEC corresponds to the official construction by Fukuda Denshi for its single-channel devices with a 63 mm wide printer, consistently confirmed in catalogues from authorised distributors (Beck-Lee, DH Material Médico, Medical Supply Direct USA, MedSTAT) and from recording paper manufacturers (TecnoCarta).

The pre-printed orange grid acts as a millimetric measurement reference (recording paper with measuring function): it allows the amplitude of the waves (mV), the duration of the intervals (PR, QT, RR) and the recording speeds (mm/s) to be assessed, facilitating the clinical interpretation of the electrocardiogram and the subsequent filing of the document in the clinical history. The 30-metre length offers high autonomy for continuous recording, avoiding frequent replacements during clinical activity. Loading the roll requires no prior configuration: simply orient the thermosensitive side according to the device’s instructions.

3. Technical Specifications

Brand / compatible system Fukuda Denshi — Cardimax electrocardiographs FCP-2101U / FCP-7101 / FCP-7102 (official construction OP-119TE / OP-119TEC)
Reference Cahnos (SKU) 0553110
Manufacturer OEM reference OP-119TE / OP-119TEC (Fukuda Denshi)
Distribution code 8723 (not verified in public sources; internal line code)
Roll dimensions 63 mm (width) × 30 m (length)
Grid colour Orange
Paper type High-sensitivity heat-sensitive thermal paper (Quicktrace® HS type quality)
Print technology Direct thermal printhead (no ink, toner or ribbon)
Commercial presentation Box of 10 rolls
Other equipment with the same format FCP-15, FCP-2101, FX-2111, FCP-2155, FCP-2201, FX-7101, FX-7102, FCP-7107, FCP-8100 (common-use data indicated by authorised distributors of OEM OP-119TE, not manufacturer specification)
Regulatory classification Class I medical device (with measuring function) · R.D. 1591/2009 · Directives 93/42/EEC and 2007/47/EC (CE marking)
Trace shelf life 5 years after printing, under suitable storage conditions
Storage 5 °C to 40 °C, cool and dry place, without direct sunlight or excess humidity
Use Single-use consumable

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer Fukuda Denshi for this consumable. The OEM reference OP-119TE is the manufacturer’s official construction and is consistently confirmed in catalogues from authorised distributors (Beck-Lee, Davis Medical, DH Material Médico, Medical Supply Direct USA, MedSTAT) and from paper manufacturers (TecnoCarta). The 63 mm × 30 m format with orange grid is a standard shared by single-channel electrocardiographs from several manufacturers; the following references have been checked against catalogues from manufacturers and authorised distributors and are classified as comparable by category, not interchangeable 1:1 without prior verification of the equipment model, grid colour and core diameter.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Fukuda Denshi (Cahnos line) OP-110TE · Cardimax FCP-2101 / FCP-11 / FX-7102 0553132-FD Comparable by category (not interchangeable 1:1) Same dimensions 63 mm × 30 m and orange grid; box of 20 rolls. Different OEM code (OP-110TE); authorised distributors (DH Material Médico) market both codes within the same format reference. Verify the exact equipment model before replacing.
DH Material Médico ECG paper Fukuda Denshi FCP15 / FCP11 / OP110TE / OP119TE · 63 mm × 30 m 400132989 Comparable by category (not interchangeable 1:1) Orange grid and box of 20 rolls; explicitly cites the OP110TE and OP119TE models. Confirmed in the authorised distributor’s catalogue.
Nihon Kohden (line Cahnos) Cardiofax V ECAPS 12/1200/1300/8110/9620 · RQS 63-3 0553132-NK Comparable by category (not interchangeable 1:1) Same dimensions 63 mm × 30 m and orange grid; box of 20 rolls. Standard format shared among single-channel devices; confirm the centre’s model before replacing.
Biocare (Cahnos line) 300 G · ECG-300 0553132-BC Comparable by category (not interchangeable 1:1) Same dimensions 63 mm × 30 m and orange grid; box of 20 rolls. Same physical format; verify paper acceptance in the equipment.
TecnoCarta (Italy) ECG thermal roll compatible with Fukuda OP-119TEC / OP-110TE · 63 mm × 30 m RM3706303016IFU Comparable by category (not interchangeable 1:1) 63 × 30 m with orange grid, no control mark and no perforation; compatibility declared with OP-119TEC (ECG FCP-2155 / FCP-15 / FX-2111 / FCP-2201). Pack of 10 rolls. Confirmed in the paper manufacturer’s catalogue.
Beck-Lee (USA) Fukuda Roll EKG Chart Paper OP-119TE · 63 mm × 30 m OP-119TE (Beck-Lee distribution) Comparable by category (not interchangeable 1:1) Same OEM code OP-119TE and same dimensions (63 mm × 30 m), with the same equipment family (FCP-15, FCP-2101, FX-2111, FCP-2155, FCP-2201, FCP-7101, FCP-7102, FX-7101, FX-7102), but with a RED grid (not orange); not interchangeable without prior verification of the colour accepted by the equipment. Confirmed in the distributor’s catalogue.
Quality Chart Paper (USA) Fukuda OP-110TE · 63 mm × 30 m FUD6330/2MU Comparable by category (not interchangeable 1:1) Same format 63 mm × 30 m, but with a RED grid (not orange) and box of 10 rolls; not interchangeable without prior verification of the colour accepted by the equipment.
Lessa / AB Medica Group (Spain) Fukuda ECG roll paper FCP-7101 / FX-7102 · 63 × 30 1006300 (SKU 300520) Comparable by category (not interchangeable 1:1) 63 × 30 m with RED grid and 12-year legibility guaranteed by the paper manufacturer. The grid colour differs from this reference (orange). Confirmed in the paper manufacturer’s catalogue.

The code 8723 accompanying reference 0553110 could not be verified in public sources and should be interpreted as an internal code of the distribution line; the official manufacturer code is OP-119TE / OP-119TEC, consistently confirmed in public sources. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.

5. Selection tips and variants of interest

  • Grid colour: confirm the colour required by your equipment. This data sheet corresponds to an orange grid; versions of the same format with a red grid (e.g. Beck-Lee OP-119TE, Quality Chart Paper FUD6330/2MU or Lessa 1006300) are not interchangeable without prior verification on the electrocardiograph. In international distribution, the OEM code OP-119TE itself is marketed with both grids depending on the market.
  • Width and length: 63 mm × 30 m is the standard format for Fukuda single-channel printers of the FCP/FX series. Also verify the roll core diameter before replacing the consumable; an unsuitable weight or grid can affect the legibility of the recording and the wear of the thermal head.
  • Variants of the same family in Cahnos: Fukuda Denshi OP-110TE roll of 63 mm × 30 m for FCP-2101 / FCP-11 / FX-7102 (ref. 0553132-FD, box of 20); Fukuda Denshi OP-122TE pad of 63 × 75 mm for FX-2201 / FCP-2155 / FCP-2201 / FCP-7101 (ref. 0553115); Z-fold pad of 63 × 100 mm for Cardisuny C-120 / Alpha 1000 (ref. 0992020). Same format and colour base: rolls 0553132-NK (Nihon Kohden Cardiofax V) and 0553132-BC (Biocare 300 G) share dimensions and grid; their suitability depends on the equipment installed at each site.
  • Storage: store the rolls in a cool, dry place away from sunlight (5–40 °C) to preserve the sensitivity of the thermal layer and prevent fogging of the trace. Recording shelf life: 5 years if the product instructions are followed.
  • Institutional purchases: for tenders, ongoing supply contracts or large volumes, contact our technical-commercial department to confirm compatibility, exact reference and a formalised quotation.

Additional information

Brand

Fukuda Denshi

Model

FCP 2101U / FCP 7101 / FCP 7102 (OP-119TE / OP-119TEC)

Manufacturer reference

OP-119TE / OP-119TEC

Roll dimensions

63 mm × 30 m

Length

30 m per roll

Grid colour

Orange

Paper type

High-sensitivity heat-sensitive thermal paper (Quicktrace® HS type quality)

Print technology

Direct thermal printhead (no ink, toner or ribbon)

Presentation

Box of 10 rolls

Compatibility

Fukuda Denshi Cardimax FCP-2101U / FCP-7101 / FCP-7102; commonly used in FCP-15, FCP-2101, FX-2111, FCP-2155, FCP-2201, FX-7101, FX-7102, FCP-7107, FCP-8100 (same 63 mm format)

Application

Electrocardiographic recording (ECG) and stress tests

Regulatory classification

Class I medical device (with measuring function) · R.D. 1591/2009 · Directives 93/42/EEC and 2007/47/EC (CE marking)

Shelf life

5 years after printing, under suitable storage conditions

Storage

5 °C to 40 °C, cool and dry place, without direct sunlight or excess humidity

Use

Single-use consumable

Product line

Fukuda Denshi (Cahnos line)

Compatible models

Cardimax FCP-2101U / FCP-7101 / FCP-7102 (OEM construction OP-119TE / OP-119TEC); commonly used in FCP-15, FCP-2101, FX-2111, FCP-2155, FCP-2201, FX-7101, FX-7102, FCP-7107, FCP-8100

OEM reference

OP-119TE / OP-119TEC (Fukuda Denshi)

Anchura

63 mm

Reviews

There are no reviews yet.

Be the first to review “ECG Thermal Paper Roll Fukuda Denshi OP-119TE / OP-119TEC · 63 mm × 30 m · Orange Grid · Cardimax FCP-2101U / FCP-7101 / FCP-7102 · Box of 10 Rolls · Ref. 0553110”