Description
1. Commercial Introduction
The Transaflow Multi-APS safety multi-patient filling system is the solution designed to standardise working processes in modern radiology: it allows contrast medium and physiological saline to be prepared and administered safely, hygienically and efficiently in computed tomography (TC/CT) and magnetic resonance imaging (RM/MRT) examinations.
Thanks to its closed-system design and standardised connections, this dual-head system is compatible with the dual-head (dual-piston) syringe injectors commonly used in radiology departments, allowing continuous application for up to 12 hours without having to replace the entire system: only the patient line is changed between patients. Quality “Made in Germany”, manufactured in a cleanroom and endorsed by the Deutsche Gesellschaft für Krankenhaushygiene (DGKH).
2. Technical explanation of the procedure
The system is inserted between the contrast medium and saline containers and the injector syringes. The suction lines, colour-coded to avoid confusion (blue = NaCl, yellow = contrast medium), are inserted into the containers using vented spikes; the injector aspirates the fluid through the filling system and delivers it to the patient through the patient line (smooth PWL or spiral PWLS) in each examination.
Four high-quality non-return valves with defined opening pressure ensure unidirectional flow and prevent mixing or backflow; the self-sealing Luer-Lock adapter, with a homogeneous disinfectable surface, prevents contamination after each disconnection of the patient line. The closed design prevents dripping and adhesion even with repeated use, and the germ barrier integrated into the patient lines prevents bacterial and viral contamination of the system, allowing only the patient line to be replaced at each patient change.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Manufacturer | Transatlantic Handels-Gesellschaft Stolpe & Co. mbH (Neu-Anspach, Germany) |
| Family | Transaflow Multi-APS safety — multi-patient filling system |
| Injector type | Dual-head (dual-piston) |
| Application duration | Up to 12 hours (12 safety version) |
| Compatibility | Standard syringe injectors for CT and MRI; standardised connections DIN EN 20594-1 / DIN EN 1707 |
| NaCl line | 100 cm, blue (with ventilated spike); version with extended NaCl line |
| Contrast line | 60 cm, yellow (with ventilated mini spike) |
| Safety valves | 4 non-return valves with defined opening pressure |
| Patient connection | Self-sealing, disinfectable Luer-Lock, homogeneous surface |
| Materials | Free from PHT, DEHP and latex |
| Certification | Inspected and tested by the DGKH (German Society for Hospital Hygiene) |
| Production | Manufactured in a cleanroom in Germany — “Made in Germany” |
| Use | Multi-patient: replace the patient line for each patient |
Available references for the Transaflow Multi-APS family
| Reference Transatlantic | Application duration | System | Type | Weight |
|---|---|---|---|---|
| 2590312 | 12 hours | Dual-head filling system | 12 safety | 1.317 kg |
| 2590311 | 12 hours | Dual-head filling system | 11 safety | 1.435 kg |
| 2590355 | 12 hours | Dual-head filling system | 55 safety | 1.11 kg |
| 2590313 | 12 hours | Closed MONO single-head filling system | 13 safety | 1 kg |
| 2590320 | 12 hours | Closed bag filling system | 20 safety | — |
| 2590401 | 24 hours | Dual-head filling system | 12 safety | 1.11 kg |
4. Equivalences and Cross-References
This product corresponds to the manufacturer’s original range Transatlantic (Transaflow Multi-APS family, head reference 2590312, dual-head 12 safety variant). There is no manufacturer-validated equivalence table that would allow references from other brands to be declared as 1:1 interchangeable; compatibility always depends on the specific injector, the head type (single or dual) and the system’s standardised connectors.
By category, the multi-patient filling systems for dual-head contrast injectors with 12/24-hour application from Bayer Radiology (MEDRAD® Stellant MP and MRXperion range), Guerbet (OptiVantage® Multi-use system), Nemoto (12/24 h multi-patient transfer sets for Dual Shot alpha 7 and SonicShot 7) and Medtron (Accutron®) offer a comparable function at category level, but they are not 1:1 interchangeable with the Transaflow range: each manufacturer homologates its consumables against its own injector and the connection and usage protocol must be verified before any replacement. The 12/24 h pressure syringes from the Transaflow brand (refs. 2840100, 2850100) are validated for use together with this filling system, as are the Transaflow PWL and PWLS patient lines with germ barrier.
5. Selection tips and variants of interest
Select the variant according to your injector and clinical routine:
- Dual-head injector (CT or MRI) with 12 h application: refs. 2590312 (12 safety), 2590311 (11 safety) or 2590355 (55 safety), depending on line configuration.
- Single-head mono injector: ref. 2590313 (13 safety, closed MONO system).
- Working with contrast/saline bags: ref. 2590320 (20 safety, closed-bag system).
- Routines of more than 12 hours (up to 24 h): ref. 2590401 (12 safety, 24 hours, dual-head).
- Patient lines: smooth PWL (2580436 – 150 cm, 2580424 – 200 cm, 2580500 – 300 cm, 2580472 – 200 cm with rotation) or spiral PWLS (2580425 – 200 cm, 2580437 – 150 cm, 2580443 – 300 cm, 2580445 – 250 cm).
- 12/24 h pressure syringe plungers: refs. 2840100 and 2850100 (1 x 200 ml) and the rest of the range according to filling volume.
For volume orders, supply contracts or tenders, please contact the technical-commercial team at Cahnos, who will prepare a quotation tailored to your needs.