1. Commercial Introduction
The Transaflow 200 ml pressure syringe plunger (24-hour version) is the component of the Transatlantic multi-patient syringe system that allows contrast media and physiological saline to be administered with maximum safety and precision in radiology departments. Manufactured by the German manufacturer Transatlantic Handels-Gesellschaft Stolpe & Co. mbH, this plunger is approved for continuous use of up to 24 hours when used in combination with the Transaflow Multi-APS multi-patient filling systems, and connects to the most common commercial single- or dual-head pressure injectors in CT and MRI.
2. Technical explanation of the equipment and procedure
The plungers (kolben) of the Transaflow multi-patient system are specifically designed for the injection of contrast media and saline solution using pressure injectors. The assembly is placed between the contrast or saline container and the injector syringe: the filling system draws the fluid through the colour-coded lines and expels it to the patient through the patient line (smooth PWL or spiral PWLS) during each examination.
Thanks to this closed, multi-patient design, only the patient line needs to be replaced between patients, keeping the plunger and the circuit in optimal condition throughout the working day. The 24-hour version is indicated for high-volume routines, such as computed tomography with prolonged contrast administration. Main fields of application: radiology, CT (CT), MRI (MRT), contrast media application and clinical logistics.
3. Technical Specifications
Reference available
| Reference Transatlantic | Filling volume | Application duration | Weight |
|---|---|---|---|
| 2850100 (TRA-2850100) | 1 x 200 ml | Up to 24 hours | 8 kg |
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Weight | 8 kg |
| PZN | 19799804 |
| GTIN / EAN | 4050856048370 |
General characteristics
| Characteristic | Specification |
|---|---|
| Brand / manufacturer | Transatlantic Handels-Gesellschaft Stolpe & Co. mbH (Germany) |
| Product family | Transaflow Multi-Patienten Spritzensystem (multi-patient syringe system) |
| Version | 24 hours (multi-patient application) |
| Intended use | Administration of contrast media and physiological saline |
| Compatibility | Commercial pressure injectors; connection to Transaflow Multi-APS multi-patient filling systems |
| Applications | Radiology | CT | MRI (MRT) | contrast administration | clinical logistics |
4. Equivalences and Cross-References
This product corresponds to the original manufacturer reference Transatlantic (ref. 2850100, TRA-2850100) within the Transaflow family. There is no manufacturer-validated equivalence table that allows references from other brands to be declared as 1:1 interchangeable: each manufacturer approves its consumables against its own injector, and the connector and usage protocol must always be verified before any replacement.
At category level, the 12/24 h multi-patient pressure plungers and syringes from Bayer Radiology (MEDRAD® Stellant MP and MRXperion range), Guerbet (OptiVantage® system), Nemoto and Medtron (Accutron®) offer a comparable function, although they are not 1:1 interchangeable with the Transaflow range.
Within the Transaflow family itself, this 24-hour version is complemented by the range of 12-hour plungers (refs. 2840100, 2840001, 2840002, 2840400 and 2840411), the Transaflow Multi-APS multi-patient filling systems (refs. 2590312, 2590311, 2590355, 2590313, 2590320 and 2590401) and the smooth PWL and spiral PWLS patient lines with germ barrier, all validated for combined use.
5. Selection tips and variants of interest
- Ref. 2850100 (1 x 200 ml, 24 h): indicated for high-volume CT routines requiring continuous application of up to 24 hours, compatible with dual-head pressure injectors.
- For half-day routines (up to 12 hours), the Transaflow plunger range offers ref. 2840100 (1 x 200 ml) and other volume variants (2840001 of 2 x 65 ml, 2840002 of 1 x 65 ml + 1 x 115 ml, 2840400 of 1 x 60 ml and 2840411 of 1 x 100 ml).
- Complete the system with the Transaflow Multi-APS 12/24 h multi-patient filling system (ref. 2590401 for 24 hours) and the PWL or PWLS patient lines appropriate for the injector-patient distance.
For volume orders, supply contracts or tenders, request a no-obligation quote from the technical-commercial team at Cahnos.