Description
1. Introduction
The Professional Fixing Belt ProBelt 200 J10 from Pearltec is the reference solution for the safe, hygienic and reproducible immobilisation of the patient during computed tomography (CT) and conventional X-ray (RX) examinations, on tables with a side rail from Philips equipment. Its 200 mm band with ergonomic design guarantees stable and comfortable immobilisation, reducing patient movement and improving image sharpness in high-throughput diagnostic imaging departments.
2. Technical explanation of the equipment
The ProBelt system is the first completely Velcro-free fixation belt system on the market. The belt is inserted into the standard side rail of the examination table and is closed by means of an eye-and-hook mechanism, with no Velcro in contact with the skin and no metal buckles. This allows quick, intuitive and reproducible fixation on the desired anatomical region, ensuring correct immobilisation even with traumatised, disoriented, elderly or uncooperative patients.
- Total radiotransparency: the polyurethane film fabric (PU/TPU) does not interfere with image quality, making it suitable for both CT and X-ray.
- Hygienic Velcro-free surface: its smooth finish can be disinfected with standard commercial disinfectants or alcohol up to 90%, complying with cross-infection prevention protocols.
- Ergonomic support: the 200 mm band distributes pressure evenly and promotes correct spinal alignment, contributing to lumbar and thoracic stability during the scan.
- Durable and breathable materials: high-quality, they ensure a secure and personalised fit even during long working shifts.
- Reusable and durable: designed for high-throughput rooms with a long service life.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Model | ProBelt 200 J10 |
| Manufacturer | Pearltec (ProBelt system) |
| Manufacturer reference | Art. 1241 |
| Reference Cahnos | 1242-PS |
| Band width | 200 mm (20 cm) |
| Length | 65 cm |
| Material | Polyurethane sheet (PU/TPU), without Velcro |
| Closure system | Eyelet and hook |
| Table compatibility | Philips (CT and X-ray), side rail |
| Approximate weight | 160 g |
| Radiotransparency | Yes, compatible with CT and X-ray |
| Disinfection | Alcohol up to 90% |
| Presentation | Unit |
4. Equivalences and Cross-References
The ProBelt 200 J10 belongs to the Pearltec fixation belt family, which share the same 200 mm base and differ by the rail adapter according to the equipment manufacturer. According to the manufacturer’s technical documentation:
| Variant | Compatibility | Manufacturer article | Reference Cahnos |
|---|---|---|---|
| ProBelt 200 R2 | GE (General Electric) and Philips | Art. 1170 | 1171-PS |
| ProBelt 200 R3 | Siemens and Philips | Art. 1171 | 1172-PS |
| ProBelt 200 T5 | Canon and Philips | Art. 1172 | 1173-PS |
| ProBelt 200 J10 | Philips | Art. 1241 | 1242-PS |
| ProBelt 200 Thorax PFC | Arm immobilisation in chest and abdominal CT | Art. 1173 | 1175-PS |
| ProBelt 200 Extension | All ProBelt 200 models | Art. 1213 | 1213-PS1 |
| ProBelt 350 J10 | Philips | Art. 1242 | 1244-PS |
| ProBelt 350 Extension | All ProBelt 350 models | Art. 1217 | 1217-PS11 |
5. Selection tips and variants of interest
Check the equipment manufacturer and the type of side rail on the table: the J10 model is designed for Philips tables, while the R2 (GE), R3 (Siemens and Philips) and T5 (Canon and Philips) variants cover the rest of the usual equipment in the 200 series.
If you need to adjust the belt for patients with a larger girth, the ProBelt 200 Extension (Ref. 1213-PS1) extends the fixation range of all models in the 200 series. For Philips tables requiring a larger support surface, the ProBelt 350 J10 variant (Ref. 1244-PS) offers a 350 mm band.
For departments with several machines of different brands, it is recommended to have the corresponding variants or the universal extension to ensure complete coverage of the rooms. Belt care is simple: clean with standard disinfectants or alcohol up to 90% and allow to air dry, keeping its fixation and hygiene properties intact. Ref. 1242-PS.