Description
ProBelt 140 extension of 65 cm: the perfect complement to extend the adjustment range of your ProBelt 140 belts in MRI rooms with Philips equipment. This Pearl Technology accessory turns your range of ProBelt 140 belts into a flexible and secure fixation system, capable of accommodating patients of any build without compromising stability or comfort during the examination. Simple, durable and easy to maintain, it is the practical solution that every radiology department needs to optimise patient fixation and improve image quality in every MRI study.
How the extension works and why it is key in RMI
The extension attaches to the end of any ProBelt 140 belt, increasing its total length by 65 cm, allowing comfortable and adjustable tensioning around the patient when the original strap falls short, a common situation in patients of larger build or in chest and abdomen fixations. As with the rest of the ProBelt system, it uses a hook-and-eye closure mechanism completely free of Velcro: the strap does not come into direct contact with the skin and can be disinfected immediately with standard commercial disinfectants. Made from materials compatible with the magnetic environment, with no ferromagnetic components and radiotransparent, it does not interfere with image quality and guarantees hygienically safe reuse, minimising the risk of cross-contamination between patients in high-turnover rooms and reducing patient movement, a decisive factor in obtaining clear and reproducible images.
Technical specifications
| Brand and manufacturer | Pearl Technology (ProBelt system) |
| Model | ProBelt 140 extension for MRI (RMI), for Philips |
| Manufacturer reference | Art. 1240 |
| Reference Cahnos | 1241-PS |
| Extension length | 65 cm |
| Compatibility | All ProBelt 140 belts (MRI tables Philips) |
| Application | Length extension and patient adjustment in MRI (RMI) studies |
| Closure system | Hook and eye, completely without Velcro |
| Material | Smooth polyurethane (PU) surface, resistant, durable and compatible with the MRI environment |
| Hygiene | Disinfection with standard disinfectants; hygienically safe reuse |
| Safety | Suitable for MRI, valid for RMI |
| Use | Reusable |
| Presentation | 1 unit |
Equivalences and cross-references
The ProBelt 140 Extension (manufacturer’s Art. 1240) belongs to the ProBelt fixation system family from Pearl Technology, the first strap system completely free of Velcro for hygienic patient fixation on the imaging table. According to the manufacturer’s technical documentation, the ProBelt series for magnetic resonance imaging consists of the following official references, marketed at Cahnos:
| Model | Compatible equipment | Manufacturer article | Reference Cahnos |
|---|---|---|---|
| ProBelt 140 MRI P | Philips | Art. 1219 | 1220-PS |
| ProBelt 140 MRI P Extension | Philips (all ProBelt 140) | Art. 1240 | 1241-PS |
| ProBelt 200 U5 | Canon | Art. 1259 | 1260-PS |
| ProBelt 200 R2 | GE General Electric | Art. 1170 | 1271-PS |
| ProBelt 200 Extension | All ProBelt 200 | Art. 1213 | 1214-PS |
| ProBelt 350 U5 | Canon | Art. 1260 | 1261-PS |
| ProBelt 350 R2 | GE General Electric | Art. 1214 | 1215-PS |
| ProBelt 350 Extension | All ProBelt 350 | Art. 1217 | 1217-PS111 |
For computed tomography and conventional radiology, the same family offers 65 cm extensions in the ProBelt 200 variants for CT and X-ray (ref. 1213-PS1) and ProBelt 350 for CT and X-ray (ref. 1217-PS11), which share the same hook-and-eye system.
Selection tips and variants of interest
Select the ProBelt 140 Extension when you need to extend the length range of the strap for patients of larger build, specific protocols or additional chest and abdomen fixations during MRI studies with Philips equipment. Verify that your base belt belongs to the ProBelt 140 series: this extension is compatible with all its MRI models. If your fleet includes equipment from other manufacturers, the same family offers the ProBelt 200 U5 for Canon (ref. 1260-PS), the ProBelt 200 R2 for GE (ref. 1271-PS), the ProBelt 350 U5 for Canon (ref. 1261-PS) and the ProBelt 350 R2 for GE (ref. 1215-PS), each with its corresponding 65 cm extension. Maintenance: clean with standard disinfectants or alcohol up to 90% and allow to air dry, keeping its holding and hygiene properties intact. Contact our technical-commercial team at Cahnos to configure the most suitable replacement batch for your equipment and examination volume.





Reviews
There are no reviews yet.