We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

2 mm black adapter clips for electrostimulation and TENS – Pack of 10 units (Ref. 28390)

19,95 €

2 mm adapter clips in black (ref. 28390), supplied in a box of 10 units, for the quick and secure connection of electrodes to the output cables of electrostimulation, TENS, EMS and thermotherapy equipment. Their clip system guarantees a firm fit and stable electrical contact throughout the session, avoiding slack that could cause signal loss or hot spots during application. Manufactured as a Class I medical device, they allow you to replace or expand the wiring of your stimulators in physiotherapy practices, rehabilitation units and sports centres. For large orders you can request a quote: ask our technical-commercial team for conditions and availability.

Sales unit: caja de 10
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM28390

Description

1. Commercial Introduction

The 2 mm adapter clips in black (ref. 28390) are the ideal replacement and expansion for the wiring of your electrostimulation, TENS and thermotherapy equipment. Designed to safely adapt and secure the cables and electrodes to the stimulator socket, these parts ensure a stable and durable connection in daily use in physiotherapy practices, rehabilitation centres and sports medicine. They are supplied in a box of 10 units, designed to cover spare parts and material supplies in a single order.

2. Technical explanation

The adapter clips are connection parts that are inserted between the stimulator and the electrode or application cable. The 2 mm measurement corresponds to the diameter of the connection socket, a common format in professional and ambulatory electrostimulation equipment. Their clip system allows a firm and reproducible press-fit, avoiding slack that could cause signal loss or hot spots during application, and facilitates the quick change of electrodes between sessions and between patients. As a manufacturer’s accessory, it maintains the same coupling tolerances as the original wiring of the brand’s equipment.

3. Technical Specifications

The technical and identification data of the product are detailed below, according to the manufacturer’s data sheet:

Product data

Field Value
Manufacturer GIMA
Manufacturer reference 28390
Connection diameter 2 mm
Colour Black
Sales unit Box of 10 units
Device type Medical device (medical device)
Device class I
CND Z12050380
GMDN 40811
EAN 8033695721617

Available family references

Reference Description EAN
28390 2 mm adapter clips – black (this product) 8033695721617
28391 2 mm adapter clips – red 8033695721624
28392 4 mm adapter clips – black 8033003263013
28393 4 mm adapter clips – red 8033003263020

4. Equivalences and Cross-References

There is no validated equivalence table cross-referencing reference 28390 with parts from other manufacturers; this adapter clip is marketed as an original accessory in the electrostimulation range, and the equipment’s connection diameter should always be checked before replacing any wiring part. Within the same catalogue family, reference GM28391 (2 mm adapter clips in red) is the equivalent variant that differs only in colour, with identical diameter, presentation and classification. For mixed configurations or spare parts for other equipment, please consult our technical-commercial department to validate exact compatibility before placing the order.

5. Selection tips and variants of interest

Before choosing the adapter, check the diameter of your stimulator’s socket: this product (ref. 28390) is the one indicated for 2 mm connections, as is the red variant (ref. 28391), while references 28392 and 28393 cover 4 mm sockets. The colour of the part allows each variant to be quickly identified and keeps the wiring organised by channel or application area. It is recommended to keep a small replacement stock per unit, as repeated clipping is the most demanding point of the connection system; replace any part that shows slack or wear to maintain a stable signal during the session. For institutional orders, tenders or continuous supply contracts, contact the Cahnos commercial team to confirm the exact reference, availability and formalised quote.

Additional information

Manufacturer

GIMA S.p.A.

Manufacturer reference

28390

Connection diameter

2 mm

Presentation

Box of 10 units

Device type

Medical device (medical device)

CND code

Z12050380

GMDN code

40811

EAN

8033695721617

Use

Electrode connection in electrostimulation, TENS, EMS and thermotherapy equipment

Presentacion

Box of 10

Tipo dispositivo

Medical device

Clase sanitaria

I

Color

Black

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “2 mm black adapter clips for electrostimulation and TENS – Pack of 10 units (Ref. 28390)”

Your email address will not be published. Required fields are marked *