Description
1. Commercial Introduction
The plastic hand dynamometer is the ideal instrument for objectively measuring grip strength in physiotherapy practices, rehabilitation units, sports medicine, occupational therapy and ergonomics. Its lightweight and robust plastic design, direct reading and affordable price make it a practical and accessible solution for centres that need to carry out functional assessments quickly and repeatably. A simple and effective ally for measuring the evolution of the patient’s strength throughout treatment.
2. Technical explanation of the equipment
This grip strength meter works with a mechanical spring mechanism: when pressure is applied with the hand, the applied force deforms the internal spring and the indicator moves over a scale graduated in kilograms (0-75 kg). One of its operational advantages is the maximum-holding needle: the indicator remains at the highest value reached until the professional returns it to zero using the reset, avoiding reading errors. The manufacturer indicates that the measurements are approximate or indicative in nature, making it especially suitable for the evolutionary follow-up of hand grip and the monitoring of strengthening programmes.
3. Technical Specifications
The dynamometer is supplied in a blister pack and includes an instruction manual in Spanish, French, Italian and English (ES, FR, IT, GB). The product data and the manufacturer’s reference technical features are detailed below.
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 28790 |
| SKU Cahnos | GM28790 |
| Sales unit | 1 pc |
| Device type | No medical device (not a medical device) |
| EAN | 8023279287905 |
Technical features
| Parameter | Specification |
|---|---|
| Instrument type | Manual spring dynamometer |
| Frame material | Plastic |
| Function | Measurement of hand grip strength (grip strength) |
| Measurement range | 0-75 kg |
| Indicator type | Maximum-holding needle (remains at the maximum value until reset) |
| Measurements | 20 x 15 cm |
| Accuracy | Approximate / indicative measurements |
| Presentation | Blister |
| Instruction manual | GB, FR, IT, ES |
4. Equivalences and Cross-References
Reference 28790 corresponds to the plastic hand dynamometer according to the manufacturer’s official catalogue (Product_DB.csv). No validated 1:1 equivalence tables with references from other manufacturers are available in the sources consulted: mechanical hand dynamometers share the same purpose of measuring grip strength, but differ in construction material, load range and reading mechanism, so any substitution must be validated with our technical department before fixing the reference in a tender.
5. Selection tips and variants of interest
For a reliable assessment of grip strength, it is recommended to perform three attempts per hand following a standardised protocol (shoulder adducted and elbow flexed at 90°), recording the best value for each limb and comparing it over time with the same instrument. This plastic model with a 0-75 kg range is a practical and economical option; if a greater measurement range and a more robust construction are required, Cahnos offers the Smedley hand dynamometer in aluminium (ref. 28791, range 0-100 kg) with an adjustable handle. Consult our technical-commercial team to configure the most suitable solution for your centre and request a quote without obligation.