Description
1. Commercial Introduction
The disposable pre-gelled electrodes of 45×80 mm (ref. 28317) are the ideal replacement consumable for 2-channel electrotherapy and electrostimulation sessions in physiotherapy clinics, rehabilitation units and aesthetic centres. They are supplied in a set of 4 ready-to-use units: they are removed from the sachet, placed on the area to be treated and connected directly to the equipment, without any gel preparation or subsequent cleaning. Being single-use and latex-free, they guarantee maximum hygiene and prevent cross-contamination between patients.
2. Technical explanation
The surface electrode acts as an interface between the electrostimulation equipment and the patient’s skin, transmitting the electrical impulses from the active channel to the area to be treated. Its conductive solid gel, integrated from the factory, ensures low contact impedance and a uniform distribution of the current, avoiding hot spots and discomfort during the session. The high flexibility of the backing material allows the electrode to adapt correctly to the anatomy of the treated area, while the solid gel keeps the adhesion and conductive properties unchanged throughout the procedure. Being a single-use product, the electrode is discarded after each session, maintaining a hygienic and reproducible clinical practice.
3. Technical Specifications
Disposable pre-gelled surface electrode for electrotherapy and electrostimulation with the following main characteristics:
| Characteristic | Value |
|---|---|
| Type | Disposable pre-gelled electrode, single-use |
| Measurements | 45 x 80 mm |
| Gel | Solid (pregelled) |
| Support material | High flexibility |
| Latex | Latex-free |
| Application | Electrotherapy and electrostimulation, 2 channels |
| Reference | 28317 |
Available references
| Reference | Measurements | Sales unit |
|---|---|---|
| GM28317 | 45×80 mm without cable | Box of 4 units |
| GM28351 | 40×40 mm with cable | Box of 4 units |
| GM28372 | 46×47 mm with cable | Box of 4 units |
| GM28373 | 45×80 mm with cable | Box of 4 units |
| GM28384 | 45×35 mm with cable | Bag of 4 units |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | Box of 4 units |
| Device type | Medical device |
| Device class | I |
| CND | N010299 |
| GMDN | 17191 |
| EAN | 8033695723581 |
4. Equivalences and Cross-References
Reference 28317 is the official distribution code for this set of 4 pre-gelled electrodes of 45×80 mm without cable, identified in the Product_DB catalogue as “Kit 4 electrodes STIM Base – 2 channels”. No equivalence table validated by the manufacturer has been found that authorises a 1:1 cross-reference with specific codes from other brands. Within the catalogue itself there is a variant of the same size with a 10 cm cable and 2 mm connection (ref. GM28373), as well as the other formats in the pre-gelled electrode family with cable (GM28351, GM28372 and GM28384). Any comparison with other manufacturers should be understood as comparable by category (disposable pre-gelled electrode in solid gel for electrostimulation) and never as interchangeable without prior verification. To confirm specific equivalences, contact the technical department of Cahnos.
5. Selection tips and variants of interest
These electrodes are intended as a replacement consumable for multichannel sessions: the set of 4 units covers a complete session on a 2-channel device. Check the connection type of your cables before ordering: ref. GM28317 is supplied without cable and requires patient cables with a compatible terminal; if your device uses electrodes with an integrated cable, the variant of the same size 45×80 mm with cable (ref. GM28373) is the most direct option. For smaller surface areas, the 40×40 mm (GM28351) and 46×47 mm (GM28372) formats are available, and for smaller elongated areas, the 45×35 mm with cable variant (GM28384). Prepare the skin simply: clean and dry, without creams or oily residues, to optimise contact impedance. Keep the sachets sealed in a dry place and respect the expiry date on the packaging, as the gel may lose conductivity if the sachet deteriorates. Single-use product; for volume orders or tenders, contact the technical-commercial department of Cahnos.