Description
1. Introduction
The TENS foam electrode 40×40 mm with integrated lead and 2 mm socket-type connector (Ref. PG871/40W) is the disposable consumable your clinic or physiotherapy centre needs to keep its electrostimulation equipment always operational. Made with high-density foam backing and conductive adhesive gel, it offers stable, comfortable and uniform contact with the skin, with the guarantee of a new electrode each session: maximum hygiene, consistent adhesion and predictable performance in every treatment. Its presentation in a bag of 40 units reduces the cost per electrode and simplifies stock management in high-use environments.
2. Technical explanation
Transcutaneous electrical nerve stimulation (TENS) uses low-frequency electrical pulses for pain relief, while electrical muscle stimulation (EMS) aims at muscle contraction and re-education. In both cases, the electrode is the point of contact between the device and the skin: a disposable electrode with conductive gel ensures uniform current distribution, minimises areas of high current density and avoids the loss of adhesion that appears in reusable electrodes after several uses.
This electrode consists of a fully gelified high-density foam that maintains conductivity throughout the session, and incorporates low-impedance conductive paper for homogeneous impulse transmission. Its 2 mm socket-type connector (female socket) with integrated lead is the most widespread standard in TENS/EMS electrostimulators for physiotherapy, ensuring compatibility with most equipment from leading manufacturers without the need for adapters. It is a single-patient product, latex-free and classified as a class I medical device.
3. Technical Specifications
| Parameter | Specification |
| Reference | PG871/40W |
| Electrode type | Disposable foam, fully gelified, with integrated lead |
| Support material | High-density foam |
| Gel | Solid conductive adhesive gel |
| Conductive material | Low-impedance conductive paper |
| Dimensions | 40 × 40 mm (square format) |
| Connection | 2 mm socket-type connector (female socket) with integrated lead |
| Use | Single-use (disposable), single patient |
| Compatibility | TENS/EMS equipment with standard 2 mm connector |
| Applications | Physiotherapy, rehabilitation, pain treatment, muscle toning |
| Latex | Latex-free |
| Primary packaging | 4 units in individual sachet |
| Commercial presentation | Bag of 40 units |
| Regulatory classification | Class I medical device (Directive 93/42/EEC and amendments) |
| Expiry | 24 months from the date of production |
| Storage | Temperature +5 °C to +35 °C; relative humidity 20–80 % |
Family of foam electrodes with lead and 2 mm socket-type connector (technical data sheet data):
| Reference | Format | Connection | Presentation |
| PG871/40W | Square 40×40 mm | 2 mm socket type | Bag 40 units |
| PG871/50W | Square 50×50 mm | 2 mm socket type | Bag 40 units |
| PG879/32W | Round Ø 32 mm | 2 mm socket type | Bag 40 units |
| PG879/50W | Round Ø 50 mm | 2 mm socket type | Bag 40 units |
| PG890W | Rectangular 40×90 mm | 2 mm socket type | Bag 40 units |
4. Equivalences and Cross-References
The reference PG871/40W corresponds to the official factory code of the product, verified in the manufacturer’s official catalogue (disposable fully gelified electrode, foam backing, with lead and 2 mm socket, size 40×40 mm). There is no equivalence table validated by the manufacturer that cross-references this code with other brands; the alternatives indicated below are category comparisons verified against each supplier’s catalogue or data sheet, not 1:1 equivalents. Always check the manufacturer’s technical data sheet before replacing.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| KLMED | Disposable TENS electrode with lead | 002157 (EAN 8435454002157) | Comparable by category (not interchangeable 1:1) | Format 40×60 mm instead of 40×40 mm; 2 mm connection with lead; hypoallergenic hydrophilic gel; presentation in bag of 4 units. |
| Material Médico (dhmedical) | TENS electrode 40×40 mm with lead | 400128351 | Comparable by category (not interchangeable 1:1) | Same size 40×40 mm, 10 cm lead and 2 mm socket-type connector; solid gel; CE class I medical device; backing material to be confirmed in technical data sheet; presentation in box of 4 units. |
| Calvo Izquierdo | TENS foam electrode with lead | 70108 | Comparable by category (not interchangeable 1:1) | Format 50×90 mm in foam with lead; 2 mm connection; presentation of 4 units per bag (box of 360). |
There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders.
5. Selection tips and variants of interest
First confirm the connection type of your device: if your electrostimulator uses a cable output with a 2 mm socket-type connector (like this model), this reference is the direct option. If your device uses a snap connection (corchete-snap, Compex type), choose the corresponding electrode family with button (PG871/50, PG873, PG879/75).
As for the area to be treated, the square format of 40×40 mm is ideal for small or contoured surfaces: face, hands, trigger points, cervical spine or joints; for medium-sized areas (shoulder, knee, thigh, calf) the 50×50 mm format (PG871/50W) is recommended; for small round areas, Ø32 mm (PG879/32W); and for large surfaces, the rectangular formats of 40×90 mm (PG890W) or round Ø50 mm (PG879/50W). If you prefer a more breathable backing, consider the non-woven fabric (TST) range with lead, such as reference PG470W (35×45 mm).
Remember to prepare the skin correctly (clean, dry and free of creams), store the electrodes in a dry, cool place, respect the packaging expiry date and discard the electrode after use to maintain hygiene and stimulation effectiveness for each patient.





Reviews
There are no reviews yet.