We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Pat-Sling Mobilisation Sling from Samarit Medical | Bed Lifting and Repositioning Band 20 x 50 cm | Double Grip Handles | SWL 120 kg | Ref. 450.2050

130,15 €

Pat-Sling mobilisation band from Samarit Medical AG for lifting, sitting up, laying down or repositioning the patient in bed or chair safely and with minimal effort, manageable by a single carer. Its fabric of reinforced nylon with double grip handles of two lengths on both sides distributes the force of the manoeuvre and protects the professional’s back. Measures 20 x 50 cm, safe working load (SWL) of 120 kg and weight of only 0.5 kg. Reusable and washable, with 2-year warranty and CE certification in accordance with MDR (EU) 2017/745. Official factory reference 450.2050 · UDI/GTIN 7640144461003. Ideal for large or thin patients in hospitals, care homes, rehabilitation and home care.

International shipping. Import duties and taxes are payable by the recipient.

Reference
450.2050

Description

1. Commercial Introduction

The mobilisation sling Pat-Sling from Samarit Medical AG (Switzerland) is a compact, versatile handling aid designed to sit the patient up, lay them down, lift or reposition them in bed or chair with complete safety and minimal physical effort for care staff. Its 20 x 50 cm format and double grip handles allow a single carer to perform repositioning manoeuvres with a straight back, avoiding overexertion and reducing the risk of musculoskeletal injuries.

With a safe working load (SWL) of 120 kg and a weight of just 0.5 kg, the Pat-Sling is suitable for both large and thin patients. It is an essential resource in hospitals, care homes, rehabilitation centres and home care for daily lifting, sitting up and postural repositioning work, and perfectly complements an integrated no-lift mobilisation system.

2. Technical explanation of the procedure

The Pat-Sling works as a lifting and repositioning band: the carer places the band under the patient’s trunk or the area to be mobilised and uses the double grip handles —with two different lengths on both sides— to lift, sit up or slide the patient in a controlled manner. The different-length handles allow the grip to be adapted to the carer’s height and position, facilitating sitting-up manoeuvres in bed, lateral transfers and repositioning in the chair.

Its construction in reinforced nylon fabric provides durability and a low-friction surface that reduces shearing on the patient’s skin. The handle reinforcements distribute the tension of the manoeuvre and ensure a firm grip even with heavy patients. It is a reusable product that can be washed with mild detergents, allowing continued use in high-turnover environments and integration into the centre’s hygiene and infection control protocols. Before each use, inspect the handles, seams and fabric for wear; do not use the band if you observe tears or deformations.

3. Technical Specifications

Characteristic Specification
Manufacturer reference (model) 450.2050 (Pat-Sling, Samarit Medical AG)
Product type Mobilisation sling / lifting and positioning band for bed
Size 20 x 50 cm (8 x 20 inches)
Weight 0.5 kg (1.1 lbs)
Safe working load (SWL) Up to 120 kg (265 lbs)
Material Reinforced nylon fabric with double grip handles
Grip handles Double handles with two different lengths on both sides
Personnel required 1 carer
UDI / GTIN 7640144461003
Use Reusable; washable with mild detergent and dry thoroughly
Warranty 2 years
Regulatory standard Product with CE certification, compliant with MDR (EU) 2017/745, manufactured by Samarit Medical AG (Switzerland)

Technical note: the dimensions, weight, SWL, material and handle data correspond to the official technical data sheet from manufacturer Samarit Medical AG; usage ranges are not extended without technical confirmation.

4. Equivalences and Cross-References

The reference 450.2050 corresponds literally to Samarit Medical AG’s official model code for the Pat-Sling sling, verified on the manufacturer’s official website and in the UDI/GTIN 7640144461003. The SKU marketed by Cahnos is identical to the factory reference, without transcriptions or normalisations.

There is no equivalence table validated by the manufacturer (Samarit Medical AG) for this reference; consult the technical department before using in tenders. For guidance purposes, the following products from other manufacturers with codes and specifications verified in public sources are identified:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Arjo Loop Repositioning Sling (loop sling for in-bed repositioning) MAA6000 Comparable by category (not interchangeable 1:1) Loop sling in one size for bed repositioning and lateral transfers, with a SWL of 272 kg (600 lbs) and washable at min. 70 °C (verified on Arjo’s official website and in its IFU instruction manual). Requires attachment via loops to Arjo passive lifting systems; the Pat-Sling is used manually with handles, without a hoist.
Medline ComfortGlide Patient Repositioning Sling (repositioning sheet-sling) PF162200 Comparable by category (not interchangeable 1:1) 2-in-1 sheet-sling (sliding and lifting) made of breathable material, for use with loop-type hoist harnesses (2, 4 or 6 points), available in disposable or reusable format (official website Medline). Full-sheet geometry compared to a compact handle band; requires a hoist.
Medicare System Mobi-tools Translide (tubular sliding sheet) TTE6108 Comparable by category (not interchangeable 1:1) Tubular sliding sheet of 200 x 71 cm, technical fabric of high-tenacity polyamide coated with silicone, max. load 150 kg, washable at 60 °C and CE marking according to Regulation (EU) 2017/745 (official technical data sheet from Medicare System). Tubular geometry for lateral transfers, without ergonomic lifting handles for a single carer.

As additional homologous product families in the bed repositioning sector, the following are cited: Guldmann supine transfer slings (one-size repositioning slings for turning, repositioning and supine transfers, attachment to power units) and sliding sheets from brands such as Etac (Immedia) or GBUK Healthcare; in all cases, the specific codes for 1:1 cross-referencing are pending confirmation with the manufacturer or authorised distributor. They all share the clinical indication of repositioning and lifting the bedridden patient, but differ from the Pat-Sling in geometry (handle band versus loop, sheet or tubular), material (nylon versus polyamide, polyester or silicone-coated PE) and grip system (manual handles versus loops for hoist attachment or sliding surface). They should be considered comparable at category level, not 1:1 interchangeable; any substitution in a care protocol or tender requires individual technical validation. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.

5. Selection tips and variants of interest

Within the same family of Samarit handling slings: the Pat-Sling (Ref. 450.2050, 20 x 50 cm, 120 kg) is the compact variant for positioning and repositioning the patient in bed or chair with a single carer. For lifting and mobilising in bed with two carers, the family includes the Pull-Up 6 (Ref. 450.5106, 50 x 150 cm, 150 kg) with 6 handles and non-slip band, and the Slide-Up Wide (Ref. 450.5110, 100/50 x 100 cm, 150 kg), a sliding mattress indicated for bringing the patient to a seated position with one hand.

Recommended accessories: combine this sling with the Transglide draw sheet (Ref. 471.1200), the flat sliding sheets CareGlide with handles (Ref. 450.3162) or without handles (Ref. 450.3163), and the tubular sliding sheets CareGlide (e.g. Mod. 6, Ref. 450.7180; Mod. 2, Ref. 450.0100) to complete an integrated system for lateral transfers and repositioning without lifting.

Hygiene and maintenance: wash with a mild detergent and allow to dry completely between uses; avoid aggressive products or solvents. Periodically inspect handles, seams and fabric for wear or damage before each use. Do not use if signs of tearing or deformation of the material are observed.

B2B purchase: for complete provision of units per ward, care home or supply contracts for mobilisation equipment, contact the technical-commercial team at Cahnos for special conditions, lead times and a formalised proposal.

Additional information

Reference

450.2050

Manufacturer

Samarit Medical AG (Switzerland)

Product type

Mobilisation sling / lifting and positioning band for bed

Size

20 x 50 cm (8 x 20 inches)

Weight

0.5 kg

SWL load capacity

Up to 120 kg

Material

Reinforced nylon fabric with double grip handles

Handles

Double handles with two different lengths on both sides

Use

Reusable; washable with mild detergent and dry thoroughly

Warranty

2 years

EAN

7640144461003

Regulatory standard

CE certification in accordance with MDR (EU) 2017/745

Application

Lifting, sitting up, lying down and repositioning in bed or chair

Personnel required

1 carer

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Pat-Sling Mobilisation Sling from Samarit Medical | Bed Lifting and Repositioning Band 20 x 50 cm | Double Grip Handles | SWL 120 kg | Ref. 450.2050”

Your email address will not be published. Required fields are marked *