We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Lateral Transfer Board EcoLite 180 Rollbord | Samarit Ref. 440.1180 | 180 x 50 cm Folding | SWL 160 kg | Radiology, Operating Theatre and ICU

568,10 €

EcoLite 180 Rollbord is the lateral transfer board from the EcoLite range by Samarit Medical AG (Switzerland): medium quality, moderate frequency of use and a very competitive price-performance ratio for clinics, sanatoriums and geriatric centres. Folding at the centre, it goes from 180 x 50 cm to 90 x 50 cm for easy storage and transport; it weighs only 2.8 kg and supports a safe working load (SWL) of 160 kg. Its polypropylene foam core reinforced with a nylon-silicone coating offers 20% friction at 100 kg, an antibacterial, flame-retardant, antistatic and MRI-compatible surface; radiolucent, it can remain under the patient during examinations. Ideal for radiology, operating theatres, ICU, emergency and hospitalisation wards. Ref. 440.1180 · UDI/GTIN 7640144460327.

International shipping. Import duties and taxes are payable by the recipient.

Reference
440.1180

Description

EcoLite 180 Rollbord Lateral Transfer Board · Samarit

1. Commercial Introduction

The EcoLite 180 Rollbord (Ref. 440.1180) is the lateral transfer board from the EcoLite range by Samarit Medical AG (Switzerland), designed for facilities with a medium-to-low frequency requirement: clinics, sanatoriums, medium and small geriatric centres, as well as hospitals that need a lightweight, economical and easy-to-maintain solution in radiology, operating theatres, ICU and special units.

Its centre-folding design reduces the board from 180 x 50 cm to 90 x 50 cm, facilitating storage and transport between floors. With only 2.8 kg in weight and a safe working load (SWL) of 160 kg, it allows one or two carers to perform lateral transfers without lifting the patient, protecting staff backs and minimising shear on the patient’s skin.

2. Technical explanation of the system and procedure

The board acts as a sliding bridge between two surfaces (bed-stretcher, stretcher-examination table, bed-operating table). Its internal core of reinforced polypropylene (PP) foam is covered with a silicone-coated nylon fabric with high sliding capacity: the friction measured at 100 kg is 20%, well below the effort required for a traditional manual transfer. The system is no-lift: the patient is slightly lateralised, the board is inserted under their body and they slide along it to the destination surface.

The cover is made of antibacterial, flame-retardant, non-toxic and antistatic material, easy to clean and disinfect with hospital disinfectant wipes (Ecolab type or similar). It is radiotransparent and MRI-compatible (supports fields of 1.5 and 3 Tesla), so it can remain under the patient during radiological examinations without interfering with the image. It incorporates cut-out handles in the edge profile for ergonomic handling.

3. Technical Specifications

Characteristic Specification
Manufacturer reference 440.1180 (Samarit EcoLite 180 Rollbord)
UDI / GTIN 7640144460327
Manufacturer Samarit Medical AG (Switzerland)
Product type Lateral transfer board for patients (transfer board)
Unfolded size 180 x 50 cm (70 x 20 inches)
Folded size 90 x 50 cm (35 x 20 inches) — foldable
Weight 2.8 kg / 6.2 lbs
Safe working load (SWL) 160 kg / 353 lbs
Core material Reinforced polypropylene (PP) foam covered with nylon fabric with silicone
Finishes Safety ends in PE
Friction (at 100 kg) 20%
Radiolucent Yes
MRI compatible Yes (1.5 and 3 Tesla)
Antibacterial surface Yes
Flame retardant Yes, without toxic fumes
Antistatic materials Yes
Handles Handles cut into the edge profile
Use Repeated professional use, moderate frequency, 1-2 caregivers
Cleaning Hospital disinfectant wipes (Ecolab or similar) or approved disinfectant
Disposable covers Available
Regulatory standard Medical device with CE marking, compliant with MDR (EU Regulation 2017/745)
Warranty 2 years
Estimated durability 5 years

Comparison of Rollbord / Transglide families (Samarit)

Characteristic Hightec Professional Blue Transfer Board EcoLite H-Line Transglide
High-quality product Yes Yes Yes 2/3 1/2 Yes
Intensive use Yes Yes Yes No No Yes
Lowest friction (100 kg) 15% 18% 18% 20% 25% 20%
Safety edges Yes Yes Yes No No Yes
Antimicrobial cover Yes Yes Yes Yes No No
Flame retardant Yes Yes Yes Yes No Yes
Antistatic materials Yes Yes Yes Yes Yes Yes
Lightweight Yes Yes Yes Yes No No
MRI compatible Yes Yes Yes Yes Yes Yes
Samarit no-lift system Yes Yes Yes Yes No No
Long-lasting materials Yes Yes Yes Yes No Yes
Skilled workmanship Yes Yes Yes Yes No Yes
Foldable model Yes Yes Yes Yes Yes No
Number of models 5 4 4 3 1 4
Durability (years) 10 8 8 5 3 10
Easy to clean (wipes) Yes Yes Yes Yes No Yes
Disposable covers Yes Yes Yes Yes No No
Years of warranty 3 2 2 2 1 3
SWL (safe working load) < 310 kg < 180 kg < 180 kg < 160 kg < 150 kg < 240 kg

Manufacturing differences and recommended use by range

Product family Main differences in manufacturing qualities Intended users of the item
Hightec range
Maximum frequency of use
Highest quality
  1. Internal core made of EPP (special expanded polypropylene foam). Very resistant, it can be twisted and returns to its original shape. In the bariatric model, a PE layer for greater resistance.
  2. Internal core covered with Teflon-treated nylon fabric. Highly slippery in contact with the inner part of the outer cover.
  3. Outer cover with silver laminate (antibacterial treatment) and inner part with reinforced nylon, which in contact with the inner layer make sliding optimal.
  4. Handles incorporated into the safety edge.
For use in large and medium hospitals, as well as large specialised day-care centres. Suitable for operating theatres and radiology, emergency departments and high-turnover departments.
Professional range
High frequency of use
High quality
  1. Internal core made of HDPE (special high-density polyethylene foam).
  2. Internal core covered with nylon fabric with silicone.
  3. Outer cover with antibacterial treatment.
  4. Strap-type handles on the safety edge.
For use in medium and small hospitals, as well as external day-care centres. Also suitable for operating theatres and radiology, emergency departments and medium-to-high rotation departments.
EcoLite range
Moderate frequency of use
Medium quality
  1. Internal core made of PP (reinforced polypropylene foam).
  2. Internal core covered with nylon fabric with silicone.
  3. Antibacterial treatment.
  4. Handles cut into the edge profile.
For use in clinics and sanatoriums, medium and small geriatric centres, in all departments with a medium-to-low frequency requirement.
H-Line range
Home use — occasional uses
Quality tailored to use
  1. Synthetic, lightweight inner core covered with a rigid part.
  2. Exterior nylon cover.
  3. Sewn in half.
  4. Handles attached to the core.
For use in small clinical centres and homes. Occasional use.

4. Equivalences and Cross-References

Ref. 440.1180 corresponds literally to the official model code of Samarit Medical AG for the EcoLite 180 Rollbord board, verified on the manufacturer’s official website, in the Samarit 2023 catalogue and in the CE MDR 2017/745 declaration of conformity. The UDI/GTIN 7640144460327 matches the manufacturer’s official nomenclature.

There is no equivalence table validated by the manufacturer that cross-references this reference with specific codes from other brands for foldable lateral transfer boards of 180 x 50 cm with SWL 160 kg. Below are identified products from other manufacturers with codes verified in public sources; all alternatives are comparable at category level, not interchangeable 1:1:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Medicare System (Spain) Folding Medi-roller PRO TMR6205 Comparable by category (not interchangeable 1:1) 180 x 49 cm (folds to 90 x 49 cm), 1.4 kg, sliding load up to 300 kg; PE foam core with replaceable tubular polyamide cover; radiotransparent. System with cover versus board with integrated cover.
RCN (Germany) MRI-compatible Transfer Rollboard TRB 180 Comparable by category (not interchangeable 1:1) 180 x 50 cm foldable, capacity 200 kg (higher); polyethylene with nylon cover, latex-free, suitable for MRI up to 3 T. Higher load capacity and cover system.
Transatlantic (Germany) Transaroll Silverboard Standard IM4500030 Comparable by category (not interchangeable 1:1) 180 x 50 cm foldable; monolithic polyethylene core with antibacterial silver cover; maximum load 350 kg. Much higher performance (bariatric) compared to the moderate use of the EcoLite.
Scaleo Medical Trans’Gliss (foldable) S82 10 416 Comparable by category (not interchangeable 1:1) 175 x 55 cm, max. load 200 kg; foldable with integrated handles, radiotransparent, antibacterial/antifungal coating and M2 flame retardant. Dimensions and design with strap-type handles.
Medicare System (Spain) Medi-glide (semi-rigid board) TMG6430 Comparable by category (not interchangeable 1:1) 170 x 50 x 0.5 cm, 4.12 kg, max. load 135 kg (lower); semi-rigid radiotransparent board. Shorter length and load much lower than the SWL of 160 kg.

There is no equivalence table validated by the manufacturer for this reference; consult the technical department before using in tenders. As alternatives with the same clinical indication in foldable lateral transfer boards, the professional market offers ranges from brands such as Medicare System (Medi-glide, Medi-roller), Scaleo Medical (Trans’Gliss), RCN (Transfer Rollboard) and GBUK Healthcare. In all cases, critical fields must be checked one by one before replacing: exact dimensions (180 x 50 cm versus other measurements), core and cover material (PP with nylon-silicone versus tubular covers or HDPE), maximum load (SWL), foldability, reusable use and regulatory classification.

5. Selection tips and variants of interest

Within the Samarit EcoLite range, the market offers three formats according to the application:

  • EcoLite 180 Rollbord (Ref. 440.1180) — 180 x 50 cm folding to 90 x 50 cm, SWL 160 kg, 2.8 kg. For radiology, operating theatres, ICU and special units with adult patient in full supine position.
  • EcoLite 120 Rollbord (Ref. 440.1120) — 130 x 40 cm folding to 65 x 40 cm, SWL 150 kg, 1.4 kg. For patient transfers with wounds or injuries and confined spaces.
  • EcoLite 90 Rollbord (Ref. 440.1090) — 90 x 50 cm non-folding, SWL 150 kg, 1.3 kg. For urology, gynaecology, resuscitation and emergency.

If your facility has a medium-high or intensive turnover, consider upgrading to the Professional Rollbord range (HDPE core, SWL up to 240 kg) or the Hightec Rollbord (EPP core, maximum quality, SWL up to 310 kg in the bariatric version). For heavier patients on a limited budget, the Blue Transfer Board Long Wide (Ref. 440.8300) offers 180 x 50 cm with an SWL of 240 kg. It is recommended to combine the board with disposable covers to optimise hygiene and infection control between patients. For complete provision of units, wards or supply contracts, consult the technical-commercial team at Cahnos for special conditions, delivery times and a formal quotation.

Additional information

Manufacturer reference

440.1180 (Samarit EcoLite 180 Rollbord)

EAN

7640144460327

Manufacturer

Samarit Medical AG (Switzerland)

Product type

Lateral transfer board for patients (transfer board)

Measurements

180 x 50 cm (folds to 90 x 50 cm)

Weight

2.8 kg

Material

Reinforced polypropylene (PP) foam covered with silicone-coated nylon fabric; PE finishes

SWL safe weight limit

160 kg

Friction at 100kg

20%

Foldable model

Yes, foldable in the centre

Radiolucent

Yes

MRI compatible

Yes (1.5 and 3 Tesla)

Antibacterial surface

Yes

Flame retardant

Yes, without toxic fumes

Antistatic

Yes

Handles

Cut into the edge profile

Use

Repeated professional use, moderate frequency, 1-2 caregivers

Cleaning

Hospital disinfectant wipes (Ecolab or similar) or approved disinfectant

Disposable covers

Available

Regulatory standard

Medical device with CE marking, compliant with MDR (EU Regulation 2017/745)

Warranty

2 years

Estimated durability

5 years

Reviews

There are no reviews yet.

Be the first to review “Lateral Transfer Board EcoLite 180 Rollbord | Samarit Ref. 440.1180 | 180 x 50 cm Folding | SWL 160 kg | Radiology, Operating Theatre and ICU”

Your email address will not be published. Required fields are marked *