Oxygen flowmeter 0-30 l/min with AFNOR MD connection (medical device class IIa), Ref. OXI0588 | SKU BRLOXI0588

79,13 €

High-flow oxygen flowmeter (0-30 l/min) , designed for the controlled administration of medicinal oxygen in resuscitation bays, emergency departments, hospitalisation wards, pulmonology services and critical care units. It features a nickel-plated brass body, inlet connection via AFNOR outlet for direct coupling to the terminal unit and a 9/16″ outlet for a humidifier or hose connector. The graduated scale of the flowmeter allows real-time reading of the supplied flow and adjustment is made using the front control. It includes a protective filter at the inlet of the burette and is compatible with disposable and reusable humidifiers. Medical device class IIa in accordance with Directive 93/42/EEC. Manufactured in Italy. For large orders you can request a quote: request terms from our technical-commercial team.

In stock

International shipping. Import duties and taxes are payable by the recipient.

Reference
BRLOXI0588

Description

1. Commercial Introduction

The oxygen flowmeter with AFNOR connection is the essential component for regulating and controlling the supply of medicinal oxygen in high-performance care stations: resuscitation bays, emergency departments, ICUs, hospitalisation units, pulmonology services and examination rooms. Its flow range of 0 to 30 l/min covers from low-flow oxygen therapy to applications requiring high flow rates, while its AFNOR connection ensures a direct and hermetic coupling to wall outlets and terminal units of the medical gas network. Manufactured in Italy, oxygen therapy and medical gases, it is the robust and reliable solution for professional oxygen supply.

2. Technical explanation of the equipment

The flowmeter (flow rate meter) is a measuring and regulating device that is inserted between the medical gas network outlet and the patient administration device. In this model, oxygen from the terminal unit enters through the AFNOR connection and rises up the graduated burette, where a float indicates in real time the flow being supplied (expressed in litres per minute). The flow is precisely adjusted using the control on the front of the device, allowing the professional to select the therapeutic flow appropriate for each patient. The lateral 9/16″ outlet allows connection of a humidifier (disposable or reusable) or, optionally, a hose connector when humidification is not required. A filter located at the inlet of the burette protects both the patient and the flowmeter itself from possible impurities in the circuit, and the nickel-plated brass body ensures durability and resistance in continuous clinical use.

3. Technical Specifications

Manufacturer Boscarol
Product type Flowmeter for oxygen supply
Flow rate range 0-30 l/min (litres per minute)
Flow rate indication In real time via graduated scale on the burette
Body material Nickel-plated brass
Inlet connection AFNOR connection for direct connection to the terminal unit
Outlet connection 9/16″ for humidifier or hose connector (optional)
Protective filter Located at the inlet of the burette; protects the patient and the flowmeter
Flow rate regulation Adjustment knob located on the front of the device
Compatibility Disposable or reusable humidifiers
Manufacture Made in Italy
Classification Medical device class IIa in accordance with Directive 93/42/EEC

Available references

Manufacturer reference SKU Cahnos
OXI0588 BRLOXI0588

4. Equivalences and Cross-References

This product corresponds to the manufacturer’s official reference. OXI0588, marketed in Cahnos under the SKU BRLOXI0588, without transcriptions or modifications. Within the catalogue itself, this reference has its variant with UNI connection in the flowmeters of the same family (UNI versions 0-30 l/min and 0-15 l/min), which share a nickel-plated brass body, 9/16″ outlet and filter in the burette, differing only in the connection system to the outlet. No 1:1 equivalence table validated by the manufacturer has been found in reliable sources that cross-references this reference with specific codes from other manufacturers; the AFNOR standard, the flow range and the type of outlet connection must always be verified before considering any substitution in a tender. Consult our technical-commercial department to validate equivalent alternatives.

5. Selection tips and variants of interest

Always verify the connection standard of your medical gas network: this reference mounts AFNOR outlet, making it ideal for installations with French/AFNOR standard terminal units. If your network uses a UNI connection, select the UNI variant from the same family of flowmeters. Check the required flow range: the 0-30 l/min range is the most versatile for high and medium flow rates; for low-flow applications the 0-15 l/min version offers greater reading resolution. Complete the circuit with the oxygen therapy humidifier with 9/16″ inlet (autoclavable bottle and cap) or, if administration is dry, with the 9/16″ flowmeter hose connector that replaces the humidifier. For distribution and fittings, the range includes oxygen hose conforming to ISO 5359 and fittings with crimped fixing. For large orders you can request a quote: contact our technical-commercial team for terms, availability and advice on complete oxygen therapy installations.

Additional information

Manufacturer reference

OXI0588

Product type

Oxygen flowmeter

Gas

Medical oxygen

Flow rate range

0-30 l/min

Body material

Nickel-plated brass

Inlet connection

AFNOR outlet for terminal unit

Outlet connection

9/16" for humidifier or hose connector (optional)

Filter

At the inlet of the burette, protects patient and flowmeter

Regulation

Front flow adjustment control

Compatibility

Disposable or reusable humidifiers

Manufacture

Made in Italy

Device class

Medical device class IIa in accordance with Directive 93/42/EEC