We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Hudson pressure line adapter with gas sampling port – 22M/22F connection, 360° monitoring elbow | Box of 50 units | Ref. 41642 (MDLP-HX51R)

Price on request

Hudson pressure line adapter (Medline) for gas monitoring in 22 mm breathing circuits: allows monitoring of the CO₂ sample or ventilation pressure via in-line placement on 22-M and 22-F connectors. It incorporates a monitoring elbow with 360° double swivel that prevents tension build-up in the tube and accepts tubes with an internal diameter of 5 to 7 mm. Non-sterile installation, supplied in a box of 50 units. Product on quotation: consult B2B terms with the technical-commercial team at Cahnos.

International shipping. Import duties and taxes are payable by the recipient.

Reference
MDLP-HX51R

Description

1. Commercial Introduction

The Hudson pressure line adapter from Medline is a disposable accessory designed for non-sterile installation (in-line placement) on 22-M and 22-F connection points, compatible with breathing circuits, aerosol circuits and other 22 mm connectors. It is the ideal solution for pulmonology, ICU, anaesthesia and emergency departments that need to reliably monitor the gas sample (e.g., CO₂) or ventilation pressure without interrupting the circuit. Each adapter is supplied in packs of 50 units.

2. Technical explanation of the adapter

This adapter is inserted directly into the breathing circuit between standard 22 mm connectors, creating a diagnostic port that allows the healthcare professional to extract a gas sample for analysis (capnography) or connect a pressure transducer to monitor the patient’s ventilation, without having to disconnect the circuit.

To prevent tension from building up in the tube and distorting readings or causing accidental disconnections, the monitoring elbow incorporates a 360° double swivel mechanism, which provides extra flexibility. In addition, the elbow can be connected to tubes with an internal diameter of 5 to 7 mm, expanding compatibility with different tubing systems.

3. Technical Specifications

Reference Port diameter Diagnostic port Units per box
41642 22M to 22F Yes 50
  • Installation type: Non-sterile, in-line placement (inline).
  • Connection: 22-M and 22-F connectors (22 mm circuits).
  • Mechanism: Monitoring elbow with 360° double swivel.
  • Tube compatibility: Tubes with an internal diameter of 5 to 7 mm.
  • Intended use: Connection to 22 mm circuits with gas sampling (CO₂ or ventilation pressure).
  • Sterility: No.
  • Presentation: Box of 50 units.
  • Brand: Medline (P-HX51R family).

4. Equivalences and Cross-References

The reference 41642 (SKU Cahnos MDLP-HX51R, Medline P-HX51R family) belongs to the range of monitoring adapters from the Hudson/Medline line. There is no manufacturer-validated equivalence table cross-referencing this reference with specific codes from other suppliers; any substitution between brands must be validated field by field (connection diameter 22M/22F, presence of diagnostic port and elbow type) against the technical data sheet of the manufacturer issuing the code.

As a homologous reference within the same manufacturer, the Hudson straight monitoring adapter (ref. 41669) offers the same gas sampling function with 15-M and 15-F/22-M connections, although without the 360° rotating elbow. On the market, comparable families by category are pressure line adapters and monitoring elbows for 22 mm circuits from brands such as Teleflex (Hudson RCI), whose fit must be confirmed with the technical department before any substitution.

5. Selection tips and variants of interest

To select the appropriate monitoring adapter, check: 1) the diameter of your circuit connectors (22M/22F in this model; 15M/15F-22M in the straight adapter ref. 41669); 2) the need for a diagnostic port for gas sampling or pressure measurement; and 3) the tubing gauge (this elbow accepts tubes with an internal diameter of 5 to 7 mm). If your circuit requires an orientable elbow that prevents tube strain, this adapter with 360° double swivel is the recommended option; if you prefer an openable monitoring port with a luer-lock cap, consider the straight variant from the same family. Single-patient product, non-sterile, supplied in a box of 50 units. For quotations and volume B2B terms, contact the technical-commercial team at Cahnos.

Additional information

Brand

Medline

References

41642

Port Diameter

22M to 22F

Sales unit

Box (Case) of 50 units

Manufacturer reference

41642

Family

P-HX51R

Product type

Pressure line adapter for gas sampling in 22 mm circuits

Connection

22M to 22F (compatible with breathing circuits, aerosol circuits and 22 mm connectors)

Diagnostic port

Yes

Elbow mechanism

360° double swivel to prevent tube strain

Tube compatibility

Tubes with an internal diameter of 5 to 7 mm

Use

Connection to 22 mm circuits with gas sampling (CO₂ or ventilation pressure)

Sterile

No (non-sterile installation, in-line placement)

Presentation

Box of 50 units

Documentation

Reviews

There are no reviews yet.

Be the first to review “Hudson pressure line adapter with gas sampling port – 22M/22F connection, 360° monitoring elbow | Box of 50 units | Ref. 41642 (MDLP-HX51R)”

Your email address will not be published. Required fields are marked *