Description
LANG STEREOTEST® II-R – Random dot stereopsis test
The LANG STEREOTEST® II-R represents the current standard of random dot-based stereopsis tests, with high sensitivity and specificity for the assessment of binocular vision. Its design allows rapid and reliable screening in patients of all ages, including very young children, without the need for 3D glasses.
How does it work?
The test combines a random dot pattern with a lenticular grating surface. The card is presented at reading distance and the patient is asked what they see, while observing eye movements at the same time. Recognition of the figures is only possible when the patient has complete global stereopsis: patients with amblyopia and strabismus (even of small angle) do not pass the test. The R series incorporates optical quality improvements thanks to modern digital and lenticular technology, greater homogeneity of the dot pattern (with reduced monocular recognition), rounded corners and a new laser-cut laminated surface, as well as a schematic drawing and brief instructions on the reverse for correct application.
Technical specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 31314 |
| SKU Cahnos | GM31314 |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | I |
| EAN | 7649996943064 |
| Stereoscopic figures | 4 (disparities of 600, 400, 200 and 200 arcsec) |
| Monocular visibility | 1 figure also visible monocularly |
| Examination method | Random dots + lenticular grating (without 3D glasses) |
| Conformity | MDR 2017/745 |
| Multilingual instructions | GB, FR, IT, ES, PT, DE, PL, HU, NL, CZ, SE, DK, RO, HR, GR |
| Origin | Made in Switzerland |
Equivalences and cross-references
The LANG STEREOTEST® II-R belongs to the Lang family of stereopsis tests. The LANG STEREOTEST® I-R (ref. 31312, EAN 7649996943057) is its variant with a lower disparity level, with three figures of 1200, 600 and 400 arcsec, indicated for screenings of greater disparity. No equivalents from other manufacturers have been documented in the sources consulted.
Selection advice
For general stereopsis screening in the clinic, choose the STEREOTEST II-R for its finer disparity range (up to 200 arcsec). If you need a test with greater disparity (up to 1200 arcsec), consider the STEREOTEST I-R. Both share lenticular technology without 3D glasses, suitable for all ages. Multilingual instructions are available on the manufacturer’s website.