Description
1. Product Presentation
The steel suture Premisut HRT48 Heavy in USP 6 gauge is the reference choice for highly demanding surgical procedures that require maximum tensile strength and permanent behaviour in hard tissues. Mounted with a ½ circle needle with cylindrical body and trocar point (conical tapered) of 48 mm in Heavy version, it offers a clean and controlled passage through fascia, sternum and dense connective tissue, with minimal tissue damage. A solid technical solution for operating theatres, purchasing departments and B2B tendering platforms seeking proven quality at a competitive cost per volume.
2. Technical explanation
This suture is a non-absorbable monofilament of stainless steel 316 LVM (surgical grade, conforming to ASTM F138), uncoated and metal coloured. As it is not absorbed, it remains in the tissue permanently, gradually encapsulating and maintaining excellent and stable tensile strength over time, superior to that of any suture polymer. The HRT48 Heavy needle combines the atraumatic penetration of a conical point (tapercut/tapered profile according to the manufacturer’s official data sheet) with the robustness of a heavy body and ribbed finish, facilitating passage through fascial planes, sternum and dense connective tissue, as well as improving knot retention in closures subjected to sustained load. It is supplied sterile by ethylene oxide, for single-use and not to be re-sterilised, complying with the applicable regulations for non-absorbable surgical sutures.
3. Technical Specifications
3.1. General characteristics
| Characteristic | Specification |
|---|---|
| Brand / line | Premisut (Atlas Medical) |
| Material | Stainless steel 316 LVM (monofilament, uncoated) |
| Suture type | Non-absorbable, monofilament |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle tip | Trocar / conical tapered (tapercut) |
| Needle size | HRT 48 Heavy (48 mm) |
| USP size | 6 |
| Metric size | EP 8 |
| Approximate thread diameter | 0.80 – 0.899 mm (USP/EP standard) |
| Number of threads | 4 |
| Length of each thread | 45 cm |
| Colour | Metal (natural) |
| Finish | Ribbed metal (ribbed), uncoated |
| Tissue behaviour | No absorption, gradual encapsulation, excellent tensile strength |
| Sterilisation | Ethylene oxide (EtO) |
| Use | Single-use, not re-sterilisable |
| Indications | Abdominal wound closure, sternum closure, orthopaedic cerclage and tendon repair |
| Manufacturer reference | P961HRT4806H.4 |
| Reference Cahnos (SKU) | AMP961HRT4806H.4 |
| Presentation | Box of 12 sterile units |
| Minimum order | 10 boxes |
3.2. Gauge equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 6 | 8 | 0.80 – 0.899 mm |
4. Equivalences and Cross-References
The steel monofilament suture in USP 6 gauge with a ½ circle 48 mm needle and 45 cm strands is a standard presentation in the non-absorbable suture market. Below are the references from other manufacturers found in public sources, with their level of equivalence. Important note: there is no official equivalence table validated by the manufacturer for the Premisut line against other brands. The cited references are offered as functional category comparisons verified in public sources (official catalogues, GUDID/FDA and authorised distributors) and MUST NOT be treated as direct 1:1 equivalents. Before using them in a tender or stock replacement, consult our technical department to validate the needle geometry and the tender specifications.
| Manufacturer / Brand | Family / Model | Reference code | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | ETHISTEEL / Surgisteel (316L steel) | M654G | Comparable by category, not interchangeable 1:1 | Same USP 6 gauge (EP 8), ½ circle 48 mm needle and 4 strands of 45 cm, but conventional cutting point (CCS); this reference has a conical trocar point. Verify needle geometry before replacing. |
| B. Braun | Steelex Sternum Set | G0617814 (STE SET 6 (8) 4×45 cm HRS48 LP) | Comparable by category, not interchangeable 1:1 | Same USP 6 gauge (EP 8) and 4×45 cm format, but HRS48 LP needle with sternal profile; different geometry from the conical trocar point of this reference. |
| GIMA | Trusteel (LVM 316 steel) | 22795 (gauge 6, 48 mm needle, 75 cm) | Comparable by category, not interchangeable 1:1 | Same USP 6 gauge and ½ circle 48 mm needle, but 75 cm strand instead of 45 cm and conventional cutting needle profile (Trusteel series). |
| DemeTECH | DemeSTEEL Surgical Steel | SW4x110548B6P (USP 5, DV-40 ½ circle tapercut 48 mm needle, 4×45 cm) | Comparable by category, not interchangeable 1:1 | 4×45 cm presentation with 48 mm needle, but lower USP 5 gauge and tapercut needle (cutting conical), not a pure trocar point. |
| Atramat | Stainless steel thread | KW481050X4 / G-W481050 (STEEL 5, ½ circle 48 mm needle, round cutting point) | Comparable by category, not interchangeable 1:1 | Lower USP 5 gauge and round cutting point, cutting geometry different from the conical trocar. |
| Lorca Marín | Monofilament steel suture | No publicly verified code | Pending confirmation with manufacturer | Spanish manufacturer of monofilament steel sutures for abdominal, tendon and sternal containment; code not verifiable in public sources, confirm before use. |
5. Selection tips and variants of interest
The USP 6 gauge (EP 8) with 48 mm HRT48 Heavy needle is indicated for closures that withstand high mechanical tension: sternal fixation after sternotomy, orthopaedic cerclage, abdominal wall containment and tendon repair. In the same Premisut family with HRT48 trocar point and 4 strands of 45 cm, the USP 4 (AMP961HRT4804H.4), USP 5 (AMP961HRT4805H.4) and USP 7 (AMP961HRT4807H.4) gauges are available, as well as the 40 mm HRT40 variant in USP 1 (AMP961HRT4001H.4), allowing the resistance to be adjusted to the tissue and unifying the supplier across the entire steel suture block. If a reverse cutting triangular point geometry is preferred, the Premisut Prime HS48 family offers USP 6 (AMP961HS4806.4) and adjacent gauges. A 2=1=1=1 knotting technique is recommended; hold the needle between 1/3 and 1/2 of the distance from the connection to avoid deformation and, as it is sterile single-use material, check the integrity of the packaging before opening. Store below 30 °C, away from moisture and direct sunlight. For B2B conditions, volume orders or other gauges and lengths on request, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.