We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Non-Absorbable SILK Suture PREMISUT – Straight Needle Conventional Cutting GS 60 mm, USP 1 (Metric EP 4), Black Braided, 75 cm | Box of 12 units | Ref. 542GS6001

Original price was: 24,20 €.Current price is: 14,20 €.

Non-absorbable braided silk suture PREMISUT, mounted on a straight needle with triangular point and conventional cutting edge of 60 mm (GS60) in USP 1 gauge (metric EP 4), with a 75 cm black thread coated with wax and silicone. 100% natural silk with high tensile strength, very secure knot and wound support for more than three months through gradual encapsulation. Sterilised by ethylene oxide and single-use; indicated for approximation of soft tissues, ligatures, ophthalmology and skin surgery. Ref. 542GS6001 · SKU AM542GS6001 · Box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM542GS6001

Description

1. Commercial Introduction

The braided silk suture PREMISUT is the classic choice for soft tissue closure: a non-absorbable material of natural origin with fully predictable behaviour, excellent handling and one of the most secure knot ratios on the market. This reference incorporates a straight conventional cutting GS needle of 60 mm with 75 cm of black braided thread in USP 1 calibre, one of the most in-demand configurations for manual suturing of directly accessible tissues and ligatures. It is supplied in a box of 12 units, sterile and ready for immediate use in the operating theatre, with special conditions for purchasing centres and hospital contracts.

2. Technical explanation of the material and procedure

Surgical silk is a natural protein (fibroin from Bombyx mori) whose filaments are washed, degummed, braided over a twisted core and coated with a mixture of wax and silicone. This braided multifilament structure provides excellent tensile strength, flexibility and great knot security, while the coating facilitates thread sliding through tissue, reduces the sawing effect and protects the suture area during knotting. As it is non-absorbable, the thread remains in the body producing gradual encapsulation that maintains wound approximation for more than three months.

The straight GS model needle of 60 mm, with a conventional cutting triangular point, is designed to penetrate firm tissues such as skin and mucosa with a clean, controlled cut, ideal for manual sutures in superficial planes, continuous stitches and ligatures with direct access. USP 1 calibre (metric EP 4) provides high tensile strength for areas under tension. The black colour ensures optimal contrast on the surgical field. Ethylene oxide sterilisation guarantees sterile delivery; it is a single-use product and cannot be re-sterilised.

3. Technical Specifications

Parameter Specification
Manufacturer reference 542GS6001
SKU Cahnos AM542GS6001
Brand / Range PREMISUT (standard quality)
Material 100% natural silk (fibroin), multifilament braided over a twisted core
Coating Wax and silicone
Thread structure Braided (multifilament), non-grooved finish
Gauge / USP size USP 1 (metric EP 4)
Thread diameter 0.40 – 0.499 mm (according to USP Pharmacopoeia, non-absorbable suture)
Thread length 75 cm
Thread colour Black (high visibility in surgical field)
Needle shape Straight
Tip type Conventional cutting triangular point (Conventional Cutting)
Needle size 60 mm (GS60 model)
Swaged 1 needle per suture
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Indications Approximation of soft tissues, ligatures, ophthalmology and skin surgery
Commercial presentation Box of 12 units; minimum order 30 boxes

4. Equivalences and Cross-References

Black non-absorbable braided silk with straight needle is one of the most clinically established permanent suture families. There is no equivalence table validated by the manufacturer that cross-references this exact configuration (straight GS 60 mm conventional cutting needle, USP 1 calibre, black, 75 cm) with references from other brands; the following matches are declared as comparable at category level, never as 1:1 interchangeable, and have been checked against the official catalogue and the GUDID regulatory database.

Manufacturer / Brand Family / Model Code / Reference Equivalence level Technical differences / Remarks
B. Braun Silkam® black – waxed braided silk, GS60 needle C0764690 (Silkam Black 1 [EP 4], 75 cm, GS60) Comparable by category (not interchangeable 1:1) Matches in family: non-absorbable waxed braided silk, USP 1 calibre, black, 75 cm thread and 60 mm GS60 needle. Code confirmed in the official B. Braun catalogue and in GUDID (GTIN 04038653958122). Verify the exact GS60 point geometry (conventional cutting versus reverse cutting) in the manufacturer’s data sheet before substituting.
Ethicon (Johnson & Johnson) MERSILK® – black non-absorbable braided silk F2242 (USP 1, black, 75 cm, straight KS 60 mm needle) Comparable by category (not interchangeable 1:1) Code confirmed with authorised distributors. Material, USP 1 calibre, black colour and 75 cm length match; the KS needle is straight, 60 mm, with a reverse cutting point, as opposed to the conventional cutting of the GS60: the point geometry differs. Confirm commercial presentation (box of 36 units).

There is no equivalence table validated by the manufacturer for this exact configuration (straight GS 60 mm needle, USP 1, black, 75 cm); consult the technical department before use in tenders. Other homologous families of black braided silk with a straight 60 mm needle, whose specific codes are pending verification in an official source, are: Ethicon MERSILK with KS needle (calibre pending confirmation), Aragó Silk TR-60 and Serag-Wiessner Silk; in each case verify calibre, needle size, colour and thread presentation. Before any formal substitution, check in the alternative manufacturer’s technical data sheet the exact calibre, thread length, needle geometry and size, colour, surface treatment and regulatory classification (CE/MDR). The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.

5. Selection tips and variants of interest

Assess the calibre according to the anatomical area: USP 1 calibre (metric 4) is a high thickness, indicated for soft tissues under considerable tension, vessel ligatures and planes requiring greater tensile strength; for fine skin and precision surgery, the smaller calibres (USP 3/0 and 2/0) are more versatile. Always check the needle geometry: the straight GS conventional cutting needle is ideal for directly accessible soft tissues and ligatures, while 3/8 circle formats with reverse cutting (DS series) are intended for deep sutures and closed planes.

Variants of interest within the Cahnos catalogue: AMP542GS6001 (PREMISUT Prime silk, GS60, USP 1, black, 75 cm, superior quality with improved surface); AMP542GS6001.2 (same Prime configuration in a presentation of 2 threads of 75 cm); AMP542GS6010 (USP 0) and AMP542GS6020 (USP 2/0) for intermediate gauges; AMP542DS6001 (same USP 1 silk with 3/8 circle needle and reverse cutting DS60) for deep sutures; AMP642GS6030 (GS60 monofilament nylon) as a synthetic non-absorbable alternative.

As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions based on volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Manufacturer reference

542GS6001

Product line

PREMISUT

Material

100% natural silk (fibroin), multifilament braided over a twisted core

Coating

Wax and silicone

Thread structure

Braided (multifilament), non-grooved finish

USP size

USP 1 (metric EP 4)

Thread diameter

0.40 – 0.499 mm (USP Pharmacopoeia)

Thread colour

Black (high visibility)

Tip type

Conventional cutting triangular point (Conventional Cutting)

Needle size

60 mm (GS60 model)

Swaged

1 needle per suture

Absorption

Non-absorbable; gradual encapsulation, support for more than 3 months

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Presentation

Box of 12 units; minimum order 30 boxes

Indications

Approximation of soft tissues, ligatures, ophthalmology and skin surgery

Medida de aguja

GS 60

Usp

1

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Conventional triangular

Forma de aguja

Straight, Straight Cut

Calidad sutura

Normal

Reviews

There are no reviews yet.

Be the first to review “Non-Absorbable SILK Suture PREMISUT – Straight Needle Conventional Cutting GS 60 mm, USP 1 (Metric EP 4), Black Braided, 75 cm | Box of 12 units | Ref. 542GS6001”

Your email address will not be published. Required fields are marked *