Description
1. Commercial Introduction
The Silk Suture PREMISUT PRIME in USP 4/0 gauge with a ⅜ circle DS19 19 mm needle is the reference choice for operating theatres, minor surgery clinics, ophthalmology and purchasing centres seeking a non-absorbable thread with predictable handling, full traceability and exceptional surgical feel. Natural braided silk remains today the clinical standard for soft tissue approximation and ligatures, and this Prime presentation combines it with a reverse cutting triangular point needle, the classic format for firm skin and compact tissues.
Sterile, single-use product with batch traceability, presented in a box of 12 units in individual sachets: the ideal solution to unify your permanent suture portfolio with a single B2B supplier and volume terms.
2. Technical Explanation
The thread is made from 100% natural silk (fibroin from Bombyx mori) presented as a braided multifilament, dyed black for maximum visibility in the surgical field and coated with a mixture of wax and silicone. This coating reduces capillarity, facilitates sliding through tissue and adds body without the strand becoming rigid or brittle, ensuring excellent knot security. Being non-absorbable, it does not degrade by enzymatic action: it is gradually encapsulated by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase.
The DS19 needle (⅜ circle, reverse cutting triangular point, 19 mm) concentrates the cutting edge at the tip to penetrate firm tissues such as skin and mucosa with a clean path, minimal resistance and less tissue damage, while the USP 4/0 gauge (metric EP 1.5) offers an optimal balance between fineness and strength for superficial planes. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut Prime range (official Cahnos price list).
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT PRIME (premium range) |
| Thread material | 100 % natural braided silk, coated with wax and silicone |
| Thread structure | Braided multifilament, non-ribbed |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / size | USP 4/0 (metric EP 1.5); conforms to USP and European Pharmacopoeia gauges |
| Thread length | 45 cm (1 thread with 1 needle per unit) |
| Thread colour | Black (high visibility in surgical field) |
| Needle shape | ⅜ circle (3/8 circular) |
| Tip type | Triangular reverse cutting (reverse cutting), DS profile |
| Needle body / measurement | 19 mm (DS19 profile) |
| Configuration | Single needle (1 × 45 cm) |
| Sterilisation | Ethylene oxide (EO) – sterile, single-use; do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and skin surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P541DS1940 |
| Reference Cahnos (SKU) | AMP541DS1940 |
3.2. Gauge conformity (indicative according to USP/EP Pharmacopoeia)
| USP size | Metric measurement (EP) | Approximate thread diameter | Thread length |
| 4/0 | 1.5 | 0.15 – 0.199 mm | 45 cm |
3.3. Premisut family with DS19 needle (⅜ circle, reverse cutting triangular point)
| Material / Quality | USP size | Thread | Reference |
| Prime Silk (this product) | 4/0 | 1 × 45 cm (black) | P541DS1940 / AMP541DS1940 |
| Normal Silk | 4/0 | 1 × 45 cm (black) | 541DS1940 / AM541DS1940 |
| Prime Polyester | 4/0 | 1 × 45 cm (white) | AMP871DS1940 |
| Prime Nylon | 4/0 | 1 × 45 cm | AMP641DS1940 |
4. Equivalences and Cross-References
The reference P541DS1940 corresponds to the official nomenclature of the PREMISUT Prime range (⅜ circle reverse cutting triangular point DS19 19 mm needle, USP 4/0 gauge, 45 cm black thread) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
The configuration of black braided silk 4/0 with a 19 mm ⅜ circle reverse cutting needle is highly standardised in the market, but there is no manufacturer-validated equivalence table cross-referencing this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or IFU before clinical use.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | MERSILK® – non-absorbable black braided silk, USP 4/0 (EP 1.5), 45 cm, FS-2 19 mm ⅜ circle needle, reverse cutting (confirmed in Ethicon EMEA catalogue and authorised distributors) | W329H | Comparable by category (not interchangeable 1:1) | They match on base material (natural braided silk dyed black), gauge 4/0 (EP 1.5), length 45 cm, ⅜ radius and 19 mm reverse cutting needle. Differences: exact needle profile (FS-2 vs DS19), coating (wax vs wax and silicone) and commercial presentation (box of 36 units in Ethicon vs 12 units); verify IFU before substituting. |
| B. Braun (Aesculap) | SILKAM® BLACK – natural braided and coated silk (wax/paraffin), black, 4/0 (1.5), 45 cm, DS19 19 mm ⅜ circle needle, reverse cutting (confirmed in official B. Braun catalogue) | C0762202 | Comparable by category (not interchangeable 1:1) | They match on base material (coated braided silk), gauge 4/0 (EP 1.5), length 45 cm, ⅜ radius, needle size and 19 mm reverse cutting point. Differences: exact thread coating and presentation (box of 12 or 36 units depending on market); confirm geometry and IFU before substituting. |
There is no manufacturer-validated equivalence table cross-referencing the reference P541DS1940 with other brands; the comparisons with MERSILK® and SILKAM® are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or instructions for use (IFU) before use in tendering or direct substitution. This DS19 needle geometry is only safely interchangeable within the PREMISUT system itself. Consult the Cahnos technical department to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: the DS19 reverse cutting needle is indicated for skin, mucosa and firm soft tissues that require clean penetration with minimal tearing; for lax, vascular or well-irrigated tissues, the same Premisut range offers conical point needles (e.g. HR 13 Prime in silk 4/0, AMP541HR1340).
Gauge and presentation: USP 4/0 offers an optimal balance between fineness and strength for skin and soft tissue closure. For even finer planes (facial skin, microsurgery) consider 5/0 or 6/0 gauges in the Prime silk range; for fascia or higher-tension ligatures, larger gauges. If cost is prioritised in large batches, the Normal quality version of this same configuration (AM541DS1940) maintains the same measurements and indications.
Material alternatives on the same DS19 needle: if the protocol prefers a thread with higher tensile strength, the range offers Prime 4/0 polyester (AMP871DS1940) and Prime 4/0 nylon (AMP641DS1940) in the same needle format. If you prefer an extra-long precision reverse cutting triangular point with a square body, the XDS Prime family is available in silk (e.g. AMP541XDS1340, XDS 13 mm 4/0). Consolidating the supplier across the entire suture portfolio enables volume B2B terms.
Sterility verification: product sterilised by ethylene oxide and single-use; check the blister integrity and expiry date before each use and keep the reference P541DS1940 together with the batch number for traceability in the operating theatre and in the event of a claim. For special volume B2B terms, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews