Description
1. Commercial presentation
The Braided Silk Suture PREMISUT PRIME in double-thread presentation (2 x 75 cm, DS26 needle of 26 mm, USP 1 gauge, black colour) is the B2B supply solution for operating theatres, general and skin surgery departments, ophthalmology units and purchasing centres that need a permanent natural-origin thread with predictable clinical performance and full batch traceability.
This reference mounts two ⅜-circle needles with triangular point and reverse cutting groove of 26 mm (DS26 Prime profile) on two black braided strands of 75 cm in USP 1 gauge: the classic format for skin closures under tension, firm subcutaneous tissue, larger-gauge ligatures and continuous multi-point sutures. Sterile, single-use and non-resterilisable product, presented in a box of 12 units in individual sachets, with special conditions for volume contracts and hospital tenders.
2. Technical Explanation
Silk is a non-absorbable suture of natural origin, formed by fibroin filaments (protein from the cocoon of Bombyx mori) braided over a twisted core (multifilament structure). This construction provides excellent tensile strength, flexibility and very secure knot retention (recommended knotting technique 2 = 1 = 1 = 1), classic characteristics of surgical silk. The wax and silicone coating reduces the capillarity of the thread, favours sliding through tissue and minimises the saw effect during passage and knotting.
Being non-absorbable, the thread does not degrade enzymatically: it is gradually encapsulated by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The DS26 needle of 26 mm features a ⅜ circle curvature with a triangular reverse-cutting point (body and point): the cutting edge is oriented towards the outside of the curve, so it passes through skin and firm tissues without enlarging the puncture bed, minimising trauma and improving the aesthetic result. The grooved black colour ensures optimal contrast of the strand on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, non-resterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use from the manufacturer/distributor.
3.1. General characteristics
| Parameter | Specification |
| Reference (SKU Cahnos) | AMP542DS2601.2 |
| Factory reference | P542DS2601.2 |
| Brand / Quality | PREMISUT PRIME (premium range) |
| Thread material | 100% natural silk (fibroin), multifilament braided over a twisted core |
| Thread structure | Braided (multifilament), fluted surface |
| Coating | Wax and silicone |
| Absorption type | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 1 (metric EP 4); conforms to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.40 – 0.499 mm (non-absorbable suture, according to USP Pharmacopeia) |
| Thread length | 2 threads of 75 cm (2 x 75 cm) |
| Thread colour | Fluted black (high visibility on the surgical field) |
| Needle shape | 3/8 circle (⅜ circular), body and point |
| Tip type | Reverse cutting triangular (inverted triangular), grooved |
| Needle size | DS26 (26 mm) |
| Swaged | 2 needles / 2 threads per unit (one needle per thread) |
| Recommended knotting technique | 2 = 1 = 1 = 1 |
| Sterilisation | Ethylene oxide (EO); single-use, not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and skin surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 1 | 4 | 0.40 – 0.499 mm |
3.3. Family PREMISUT PRIME DS26 (⅜ circle needle, 26 mm, triangular reverse cutting point, black thread)
| Needle profile | USP size | Thread | Reference |
| DS26 Prime | 3/0 | 1 x 75 cm (black) | P542DS2630 / AMP542DS2630 |
| DS26 Prime | 2/0 | 1 x 75 cm (black) | P542DS2620 / AMP542DS2620 |
| DS26 Prime | 0 | 1 x 75 cm (black) | P542DS2610 / AMP542DS2610 |
| DS26 Prime | 1 | 1 x 75 cm (black) | P542DS2601 / AMP542DS2601 |
| DS26 Prime | 3/0 | 2 x 75 cm (black) | P542DS2630.2 / AMP542DS2630.2 |
| DS26 Prime | 2/0 | 2 x 75 cm (black) | P542DS2620.2 / AMP542DS2620.2 |
| DS26 Prime | 0 | 2 x 75 cm (black) | P542DS2610.2 / AMP542DS2610.2 |
| DS26 Prime | 1 | 2 x 75 cm (black) | P542DS2601.2 / AMP542DS2601.2 (this product) |
4. Equivalences and Cross-References
The reference P542DS2601.2 corresponds to the official nomenclature of the PREMISUT PRIME range (DS26 profile: ⅜-circle needle with triangular reverse-cutting point of 26 mm, USP 1 gauge, two black braided threads of 75 cm, double-needle configuration) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. Non-absorbable black braided silk is one of the most standardised natural suture families on the market (commercial types Silkam, MERSILK / PERMA-HAND or Sofsilk).
There is no manufacturer-validated equivalence table that cross-references this specific configuration (DS26 needle of 26 mm, USP 1, black, 75 cm, double thread) with references from other houses; the following matches are functional comparisons at category level, verified against the official catalogue and the GUDID regulatory database, and must not be treated as 1:1 interchangeable without technical validation from the destination manufacturer.
| Manufacturer / Brand | Family / Model | Code / Reference | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | Silkam® Black – non-absorbable waxed braided silk, black | C0764892 – Silkam Black 1 (EP 4), 75 cm, DS60 needle | Comparable by category (not interchangeable 1:1) | They match in material (braided silk coated with wax/silicone), USP 1 gauge (metric EP 4), black colour and thread length of 75 cm. Code and attributes confirmed in the official B. Braun catalogue and in GUDID (GTIN 04038653835218). They differ in needle size (DS60 of 60 mm vs DS26 of 26 mm, outside ±1 mm tolerance), number of threads per unit (1 vs 2) and presentation (box of 36 vs 12). |
| Ethicon (Johnson & Johnson MedTech) | MERSILK® / PERMA-HAND™ Silk – black braided silk | F2243H – Mersilk/PERMA-HAND USP 1, black, 75 cm, FSL needle of ⅜ circle | Comparable by category (not interchangeable 1:1) | They match in material (waxed braided silk), USP 1 gauge, black colour, length of 75 cm and ⅜ circle curvature. Reference verified in authorised Ethicon distributors (GTIN 30705031242603). They differ in point geometry and size (FSL of 30 mm vs DS26 of 26 mm with reverse cutting), number of threads per unit (1 vs 2) and presentation (box of 36 vs 12). |
Other homologous families of black braided silk that must be reviewed property by property (material, gauge, curvature, point family, needle and strand length, number of threads, colour, coating and CE/MDR regulatory classification) before any substitution are: Medtronic Sofsilk™, DemeTECH DemeSILK™, Assut Surgisilk™, Lorca Marín and Laboratorio Aragó (black braided silk), Unilene Seda Negra Trenzada and Clarben Octosutur Seda; the specific codes for the DS26 + USP 1 combination in double-thread format are pending verification from an official source. This needle geometry (DS26, USP 1, 75 cm, double needle) is only safely interchangeable within the PREMISUT system itself. There is no manufacturer-validated equivalence table for this configuration; consult the technical department of Cahnos before using in tendering or direct substitution. Always verify in the technical data sheet or IFU of the alternative manufacturer the exact gauge, curvature and needle size, point geometry, length and number of strands, colour, surface treatment and regulatory classification before using this information in direct substitution.
5. Selection tips and variants of interest
Tissue to suture: the USP 1 gauge (metric EP 4, diameter 0.40–0.499 mm) provides high tensile strength, indicated for firm subcutaneous tissue, skin closures under tension, fascias, aponeuroses and larger-gauge ligatures. The reverse-cutting needle passes through dense tissues without tearing the puncture bed and improves the aesthetic result. If the tissue is very lax or delicate, consider descending to the same DS26 needle in USP 0 gauge (AMP542DS2610.2) or USP 2/0 (AMP542DS2620.2).
Needle length: the 26 mm DS26 profile is an intermediate size, suitable for confined fields and subcutaneous planes. For wider and deeper access, the same PREMISUT PRIME range offers the DS30 (AMP542DS3001.2, USP 1, 2 x 75 cm) or DS40 (AMP542DS4001, USP 1, 1 x 75 cm) profiles; for microsurgery and fine skin, the DS12/DS19 series in fine gauges.
Thread format: the presentation analysed is double-thread (2 x 75 cm, double needle), designed for high-volume services, continuous or multi-point suturing. If the service prefers a single strand, the AMP542DS2601 variant is available (same DS26 needle and USP 1 gauge in Prime quality, 1 x 75 cm); as an economical alternative in standard quality, reference AM542DS2601 (same configuration, PREMISUT range).
Sterility verification: sterile product by ethylene oxide and single-use; check the blister integrity and expiry date before each procedure, keep the reference P542DS2601.2 and the batch number for traceability in the operating theatre, and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews