We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Silk Suture PREMISUT Prime · ½ Circle Needle Cylindrical Body Trocar Point HRT18 (18 mm) · USP 3/0 · Black Braided Thread 75 cm · Box of 12 units

Original price was: 24,90 €.Current price is: 16,50 €.

Non-absorbable suture of 100% natural braided silk from the PREMISUT Prime range, with a wax and silicone coating that reduces capillarity and facilitates sliding through tissue. USP 3/0 gauge (metric EP 2), black fluted thread of 75 cm mounted on a ½ circle needle with cylindrical body and trocar point (tapercut) of 18 mm (HRT18 profile). Non-absorbable, with gradual encapsulation that maintains wound support for more than three months. Sterilised by ethylene oxide, single-use. Indicated for soft tissue approximation, ligatures, ophthalmology and skin surgery. Box of 12 units in individual sterile sachets. Factory ref. P542HRT1830 · SKU AMP542HRT1830.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP542HRT1830

Description

1. Introduction

The SEDA PREMISUT Prime HRT18 Suture (Factory ref. P542HRT1830 · SKU AMP542HRT1830) is the reference of the Prime range of non-absorbable braided silk from Cahnos for the professional who demands exceptional handling, reliable knot and predictable clinical performance in the closure of soft tissues. This presentation mounts a ½ circle needle with cylindrical body and trocar point (HRT18 profile) of 18 mm together with 75 cm of black grooved thread, coated with wax and silicone to reduce friction and facilitate passage through tissue.

Designed for operating theatre, ophthalmology clinic, dermatological surgery and minor surgery, it is presented in a box of 12 individual sterile envelopes, ready to use and with full batch traceability. It is the continuous replacement solution for surgery services, purchasing centres and B2B contracts, with a minimum order of 30 boxes.

2. Technical explanation of the material and procedure

Surgical silk is a natural protein fibre —fibroin from the cocoon of Bombyx mori— presented in a braided multifilament construction and coated with a mixture of wax and silicone. This coating minimises the capillarity of the multifilament, reduces drag when passing through tissue and improves knot seating (recommended knotting technique 2 = 1 = 1 = 1), one of the most valued qualities of surgical silk.

Being a non-absorbable material, the thread does not degrade by hydrolysis: it is gradually encapsulated by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The HRT18 needle of 18 mm has a ½ circle curvature with cylindrical body and trocar point (tapercut): a cutting point that blends into a round body, allowing to penetrate firm and non-distensible tissues without enlarging the puncture bed, minimising trauma and improving aesthetic outcome. The black grooved colour guarantees optimal contrast on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Factory reference P542HRT1830 (PREMISUT Prime range)
SKU Cahnos AMP542HRT1830
Brand / Range PREMISUT (Prime quality)
Thread material 100% natural silk (fibroin from Bombyx mori), braided multifilament
Thread structure Braided (multifilament), fluted surface
Coating Wax and silicone (anti-capillarity, low drag)
Absorption type Non-absorbable; gradual encapsulation, wound support for more than 3 months
USP gauge / size USP 3/0 (metric EP 2)
Approximate thread diameter 0.20 – 0.249 mm (USP, non-absorbable suture)
Thread length 75 cm (1 thread per unit)
Thread colour Fluted black (high visibility on the surgical field)
Needle shape ½ circle (1/2), cylindrical body
Tip type Trocar point (tapercut)
Needle size 18 mm (HRT18 profile)
Swaged 1 needle per suture
Recommended knotting technique 2 = 1 = 1 = 1
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Indications Approximation of soft tissues, ligatures, ophthalmology and skin surgery
Commercial presentation Box of 12 units (individual sterile sachets); minimum order of 30 boxes
Regulatory standard Conforms to USP/EP Pharmacopoeia; CE marking (MDR)

3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
4/0 1.5 0.15 – 0.199 mm
3/0 (this product) 2 0.20 – 0.249 mm
2/0 3 0.30 – 0.339 mm
0 3.5 0.35 – 0.399 mm

3.3. PREMISUT HRT18 family in silk (½ circle needle, 18 mm, trocar point, cylindrical body, black thread)

USP size Quality Thread Reference (SKU)
3/0 Normal 1 × 75 cm (black) 542HRT1830 / AM542HRT1830
3/0 Prime 1 × 75 cm (black) P542HRT1830 / AMP542HRT1830 (this product)
3/0 Normal 1 × 45 cm (black) 541HRT1830 / AM541HRT1830
3/0 Prime 1 × 45 cm (black) P541HRT1830 / AMP541HRT1830
4/0 Normal 1 × 75 cm (black) 542HRT1840 / AM542HRT1840
4/0 Prime 1 × 75 cm (black) P542HRT1840 / AMP542HRT1840

4. Equivalences and Cross-References

The reference P542HRT1830 corresponds to the official nomenclature of the PREMISUT range (P = Prime quality; 542 = 75 cm thread; HRT = ½ circle needle with cylindrical body and trocar point; 18 = 18 mm; 30 = USP 3/0) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering. The equivalent version in Normal quality of this same configuration is reference 542HRT1830 (SKU AM542HRT1830), identical in material, needle, gauge, colour and length.

Non-absorbable coated black braided silk is one of the most standardised families of natural suture on the market. After cross-referencing against official catalogues and regulatory databases, no product from another brand has been found that matches 1:1 in all required fields —material (coated braided silk), USP 3/0 gauge, black 75 cm thread, ½ circle curvature, trocar/tapercut point and 18 mm needle— within the established measurement tolerance (±1 mm for needles ≥ 10 mm). Therefore there is no equivalence table validated by the manufacturer; consult the technical department before using in a tender. Below are listed the closest homologous market references, verified source by source, so that the professional can assess their clinical suitability:

  • Ethicon PERMA-HAND Silk (K963G): black braided natural silk, USP 3/0, 75 cm, V-7 needle of 26 mm in ½ circle with tapercut point. Material, gauge, colour, length and point family match, but the needle is 26 mm (outside the ±1 mm tolerance compared to the 18 mm of the HRT18). Verified in Ethicon catalogue and authorised distribution.
  • B. Braun Silkam Black (C0760412): black braided natural silk, USP 3/0, 75 cm, HR26 needle of 26 mm in ½ circle with conical point (taper point), not trocar. Material, gauge and length match, but point (conical vs trocar) and needle size differ. Verified in B. Braun official catalogue.
  • B. Braun Silkam Black (G0763218): black braided natural silk, USP 3/0, 75 cm, DRT18 needle with trocar point (tapercut) of 18 mm, but with ⅜ circle curvature, not ½. Material, gauge, length, point and needle size match; curvature differs. Verified in regulatory database/RevMed.
  • DemeTECH DemeSILK: family of black braided silk with silicone coating in a wide range of gauges and needles. Code SK263026B0P (DSH 26 mm, round body, 3/0, 75 cm) has been verified, which does not match in point (round body vs trocar). No DemeSILK assembly with an 18 mm tapercut needle in ½ circle has been confirmed in an official source; consult the manufacturer before any possible substitution.

Other homologous families present in the European market — Ethicon MERSILK™, Medtronic Sofsilk™, Assut Assusilk®, SMI A.G., LuxSutures® LuxSilk, Lorca Marín Braided Silk and Serag-Wiessner — must always be checked reference by reference: USP/metric gauge, length and number of threads, geometry and exact needle size, colour, coating and CE/MDR regulatory classification before proceeding with any substitution. Consult with the technical department of Cahnos before using in a tender.

5. Selection tips and variants of interest

Gauge by area and tension: USP 3/0 (metric EP 2) offers the optimal balance between fineness and strength for skin, subcutaneous tissue, mucous membranes and soft tissues under moderate tension, as well as for ophthalmology and precision surgery. For more delicate layers (eyelids, microsurgery) consider the 4/0 gauge with the same HRT18 needle (AMP542HRT1840); for greater mechanical demand, the USP 2/0 is available with the same profile (AM542HRT1820).

Needle geometry: the 18 mm HRT18 in ½ circle with cylindrical body and trocar point is indicated for firm tissues with controlled penetration and good cosmetic results. If you work in more superficial fields and seek greater rotation control, consider the same point in ⅜ circle (AMP542DRT1830, DRT18 Prime 3/0). For greater needle reach in the same 3/0 gauge, step up to the HRT26 profile (AMP542HRT2630) or the HRT30 (AM542HRT3030).

Thread length: this reference is 75 cm (series 542); when the procedure requires a shorter length, presentations of 45 cm (series 541) are available, such as the P541HRT1830 in Prime quality.

Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep the reference P542HRT1830 together with the batch number for traceability in the operating theatre and store below 30 °C, away from humidity and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Manufacturer reference

P542HRT1830

Material

100% natural silk (fibroin from Bombyx mori) coated with wax and silicone

Structure

Braided multifilament, grooved surface

Absorption type

Non-absorbable; gradual encapsulation, support >3 months

USP size

3/0 (metric EP 2)

Thread diameter

0.20 – 0.249

Thread colour

Fluted black

Needle shape

½ circle, cylindrical body

Needle size mm

18

Swaged

1 needle per suture

Sterilisation

Ethylene oxide (EO), single-use

Presentation

Box of 12 units, minimum order 30 boxes

Indications

Soft tissues, ligatures, ophthalmology, skin surgery

Regulatory standard

USP/EP Pharmacopoeia; CE marking (MDR)

Medida de aguja

HRT 18

Usp

3/0

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Silk Suture PREMISUT Prime · ½ Circle Needle Cylindrical Body Trocar Point HRT18 (18 mm) · USP 3/0 · Black Braided Thread 75 cm · Box of 12 units”