Description
1. Commercial Introduction
The Silk Suture PREMISUT Prime 1/2 Cylindrical HR26mm is the reference in the premium range of non-absorbable sutures from Cahnos for the professional who demands exceptional handling, reliable knotting and predictable clinical performance. It combines a 100% natural silk multifilament coated with wax and silicone, in high-visibility black, with a ½ circle needle with cylindrical body and taper point of 26 mm (HR26 profile). Sterile, ready-to-use product, in a box of 12 individual pouches with batch traceability. Aimed at operating theatre, dermatological surgery, ophthalmology, skin surgery and B2B purchasing centres, with special volume conditions for hospitals, clinics and tenders.
2. Technical explanation of the material and procedure
Surgical silk is a natural protein fibre —fibroin from the cocoon of Bombyx mori— presented in a braided multifilament construction and coated with a mixture of wax and silicone. This coating minimises the capillarity of the multifilament, reduces drag when passing through tissue and improves knot seating (recommended knotting technique 2 = 1 = 1 = 1), one of the most valued qualities of surgical silk.
Being a non-absorbable material, the thread does not degrade by hydrolysis: it is gradually encapsulated by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The HR26 needle of 26 mm features a ½ circle curvature with cylindrical body and taper point: the taper point separates tissue fibres without cutting them, achieving atraumatic penetration and minimal trauma to the puncture bed, making it especially suitable for soft, lax, well-vascularised or delicate tissues. The USP 1 gauge (metric EP 4) provides high strength for planes with medium tension. The grooved black colour ensures optimal contrast on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Factory reference | P542HR2601 |
| Reference Cahnos (SKU) | AMP542HR2601 |
| Brand / quality | PREMISUT Prime (premium range) |
| Thread material | 100% natural silk (fibroin from Bombyx mori), multifilament |
| Thread structure | Braided (multifilament), fluted surface (black) |
| Coating | Wax and silicone (anti-capillarity, low tissue drag) |
| Absorption type | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 1 (metric EP 4); conforming to USP Pharmacopoeia and European Pharmacopoeia |
| Thread length | 75 cm (single strand) |
| Thread colour | Fluted black (high visibility on the surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical (taperpoint), non-cutting |
| Needle size | HR26 (26 mm), 1 needle per thread |
| Swaged | 1 needle / 1 suture per unit |
| Recommended knotting technique | 2 = 1 = 1 = 1 |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and skin surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets); minimum order 30 boxes |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 (this product) | 4 | 0.40 – 0.499 mm |
| 2 | 5 | 0.50 – 0.599 mm |
The strand diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their limits.
3.3. PREMISUT family with HR26 needle in silk (Cahnos catalogue)
| USP size | Quality | Presentation | Reference (SKU) |
|---|---|---|---|
| 4/0 | Prime | 1 × 75 cm (black) | AMP542HR2640 |
| 3/0 | Prime | 1 × 75 cm (black) | AMP542HR2630 |
| 2/0 | Prime | 1 × 75 cm (black) | AMP542HR2620 |
| 0 | Prime | 1 × 75 cm (black) | AMP542HR2610 |
| 1 (this product) | Prime | 1 × 75 cm (black) | AMP542HR2601 |
| 1 | Prime | 2 × 75 cm (black) | AMP542RHR2601.2 |
| 1 | Standard | 1 × 75 cm (black) | AM542HR2601 |
Reference decoding: P (Prime quality) + 542 (black thread of 75 cm) + HR26 (½ circle needle with taper point of 26 mm) + 01 (USP 1 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
The reference P542HR2601 corresponds to the official nomenclature of the PREMISUT Prime range (HR26 profile: ½ circle needle with taper point of 26 mm, USP 1 gauge, grooved black thread of 75 cm, single strand configuration). Non-absorbable black braided silk is one of the most standardised permanent suture families on the market (commercial types Silkam®, MERSILK™/PERMA-HAND™, Sofsilk™, DemeSILK™ or Black Braided Silk). The technical cross-reference detailed below has been verified against the official catalogue of the cited manufacturer; as it is another brand, it does not constitute an exact reference equivalence (reserved for the same manufacturer) and must be validated against the IFU and CE/MDR classification before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun (Aesculap) | Silkam® Black – natural braided and impregnated multifilament silk, coated with wax/paraffin | C0760447 – SILKAM BLACK 1 (4) 75CM HR26 (verified in official B. Braun catalogue) | Comparable by category (not interchangeable 1:1) | They match in material (coated braided silk), USP 1 gauge (metric EP 4), black colour, ½ circle curvature, HR needle family with taper point of 26 mm (HR26) and strand length of 75 cm. They differ in the coating formulation (wax/paraffin versus wax and silicone) and the sterilisation method (gamma radiation versus ethylene oxide). Confirm IFU and CE/MDR classification before substituting. |
In the Ethicon MERSILK™/PERMA-HAND™ Silk family, no taper point codes in USP 1 and 75 cm with a 26 mm needle within the ±1 mm tolerance against the HR26 of this datasheet have been verified in public sources, so they are not published as a cross-reference. The homologous market families —Ethicon MERSILK™/PERMA-HAND™ Silk, Medtronic Sofsilk™, DemeTECH DemeSILK™, Assut Surgisilk™, Serag-Wiessner, SMI Silk Braided, Unilene BLACK BRAIDED SILK and Laboratorio Aragó— must always be reviewed property by property (material, gauge, curvature, point family, needle length within ±1 mm tolerance, number and length of threads, colour, coating and CE/MDR regulatory classification) before any substitution. This needle geometry (HR26, USP 1, 75 cm thread) is only safely interchangeable within the PREMISUT system itself: the standard range variant of identical geometry and gauge (Ref. 542HR2601 · SKU AM542HR2601) is the direct equivalent within the same manufacturer. There is no manufacturer-validated equivalence table cross-referencing this specific configuration with references from other houses; consult the technical department before use in tenders. The cited brands belong to their respective manufacturers and are mentioned for reference only.
5. Selection tips and variants of interest
Tissue to suture: USP 1 gauge (metric EP 4) is the classic choice for subcutaneous tissue, skin with moderate tension, fasciae, deep planes and ligatures, always with a taper point needle to minimise tissue damage in soft tissues and in ophthalmology and skin surgery procedures. For finer planes, consider USP 0 (AMP542HR2610), USP 2/0 (AMP542HR2620), USP 3/0 (AMP542HR2630) or USP 4/0 (AMP542HR2640) with the same HR26 needle.
Variants of the same geometry: if you need extra length for continuous sutures without re-threading, the same USP 1 configuration is available in double thread 2×75 cm (AMP542RHR2601.2); if budget requires, the standard-range version of the same gauge and needle is available (AM542HR2601). Other needle sizes in the PREMISUT silk family: HR20 (AM542HR2040/2050) and HR16 (AMP542HR1640/1630/1620) for smaller fields, and HR30/HR37 for deeper planes.
Sterility verification: sterile product, ethylene oxide sterilised and single-use; check the integrity of the blister and the expiry date before each procedure, keep the reference P542HR2601 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For hospital supply agreements, public tenders or validation of equivalents from other manufacturers, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.