Description
1. Commercial Introduction
The Silk suture PREMISUT Prime is the premium reference in natural braided silk thread from Cahnos for soft tissue approximation procedures, ligatures, dermatological surgery and ophthalmology. It combines the tradition and handling of 100% natural silk (fibroin from Bombyx mori) with a Prime needle of ½ circle, cylindrical body and Taperpoint conical point of 40 mm (HR40), which passes through the tissue separating the fibres without cutting them and minimises tissue trauma. In USP 2 gauge (metric EP 5) and with a black strand of 75 cm, it offers high tensile strength and a predictable clinical knot, ideal for closures with medium-high tension. It is presented in a box of 12 sterile individual sachets, with batch traceability and stable factory reference P542HR4002.
2. Technical Explanation
The braided silk PREMISUT Prime is made up of natural protein fibres (fibroin) processed to remove natural waxes and gums, allowing a compact and uniform braid. The wax and silicone coating reduces capillarity (wicking effect), improves sliding through tissues and provides excellent knot security, with high tensile strength maintained during the critical healing period —more than three months— followed by gradual encapsulation by fibrous connective tissue. Being non-absorbable, the thread remains in the tissue providing prolonged support. The HR40 needle of 40 mm, with ½ circle curvature, cylindrical body and grooved conical point (Taperpoint), is especially suitable for soft and well-vascularised tissues (fasciae, peritoneum, muscle, mucosa and conjunctiva). The USP 2 (metric EP 5) gauge offers high tensile strength for closures with medium-high tension and retention sutures. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT Prime (premium range) |
| Thread material | 100% natural silk (Bombyx mori fibroin), braided multifilament |
| Coating | Wax and silicone (anti-capillary, low tissue drag) |
| Thread structure | Braided multifilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 2 (metric EP 5); conforming to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.45 – 0.499 mm |
| Thread length | 75 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical / cylindrical (Taperpoint), grooved, non-cutting |
| Needle size | HR 40 Prime (40 mm) |
| Configuration | 1 needle per unit, 1 thread of 75 cm |
| Recommended knotting technique | 2 = 1 = 1 = 1 |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, skin surgery, oral surgery and ophthalmology |
| Regulatory standard | Complies with USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR) |
| Commercial presentation | Box of 12 sterile individual sachets; batch traceability. Minimum order 30 boxes |
| Factory reference | P542HR4002 |
| Reference Cahnos (SKU) | AMP542HR4002 |
3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2 (this product) | 5 | 0.45 – 0.499 mm |
| 1 | 4 | 0.40 – 0.499 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their limits.
3.3. Family PREMISUT HR40 (½ circle needle of 40 mm, taperpoint conical point, black thread)
| Needle profile | USP size | Thread | Reference |
| HR 40 Prime | 2 | 1 × 75 cm (black) | P542HR4002 / AMP542HR4002 (this product) |
| HR 40 Prime | 2 | 2 × 75 cm (black, double thread) | P542HR4002.2 / AMP542HR4002.2 |
| HR 40 standard | 2 | 1 × 75 cm (black) | 542HR4002 / AM542HR4002 |
| HR 40 Prime | 1 | 1 × 75 cm (black) | P542HR4001 / AMP542HR4001 |
| HR 40 Prime | 0 | 1 × 75 cm (black) | P542HR4010 / AMP542HR4010 |
| HR 40 Prime | 2/0 | 1 × 75 cm (black) | P542HR4020 / AMP542HR4020 |
4. Equivalences and Cross-References
The reference P542HR4002 corresponds to the official nomenclature of the PREMISUT Prime range (HR40 profile: ½ circle needle with cylindrical body and 40 mm taperpoint conical point, USP 2 gauge, black braided thread of 75 cm) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. Non-absorbable black braided silk is one of the most standardised natural suture families on the market (commercial types Silkam® and MERSILK® / PERMA-HAND™ Silk). The following non-absorbable braided natural silk references with equivalent configuration have been compared in official catalogues and regulatory databases (GUDID); as they are another brand, they do not constitute an exact reference equivalence (reserved for the same manufacturer) and must be validated against the IFU before any substitution:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| B. Braun (Aesculap) | Silkam® Black – natural braided coated silk (wax/paraffin), non-absorbable, USP 2 (EP 5), 75 cm, HR40S needle | C0760560 – SILKAM BLACK 2 (5) 75CM HR40S | Comparable by category (not interchangeable 1:1) | Code and attributes confirmed in official B. Braun catalogue and GUDID: they match material (coated black braided silk), USP 2 (EP 5) gauge, black colour, ½ circle curvature, taper conical point, needle size of 40 mm (HR40S) and thread length of 75 cm. They differ: reinforced needle body (HR40S vs HR40 Prime), coating (wax/paraffin vs wax and silicone), sterilisation (gamma radiation vs ethylene oxide) and presentation (box of 36 units vs 12). Confirm IFU and CE/MDR classification before substituting. |
| Ethicon (Johnson & Johnson MedTech) | MERSILK® / PERMA-HAND™ Silk – black braided silk, USP 2, 75 cm, MO-2 ½ circle needle with conical point of 40 mm | W936 / W936G | Comparable by category (not interchangeable 1:1) | Code confirmed in Ethicon EMEA product centre and authorised distribution: they match material (natural braided silk), USP 2 (EP 5) gauge, black colour, strand length (75 cm), ½ circle curvature, conical point family and needle size (40 mm). They differ: coating (wax in Ethicon vs wax and silicone in PREMISUT Prime), designation and needle body (MO-2 vs HR40) and presentation (box of 36 sachets vs 12). Confirm IFU and CE/MDR classification before substituting. |
The reference B. Braun Silkam® C0770477 (USP 2/0, 75 cm, HR40 needle) is excluded from the table because it has a smaller gauge (USP 2/0 / EP 3 vs. USP 2 / EP 5); it is not interchangeable 1:1 by gauge. Other homologous families on the market that must be reviewed property by property (material, gauge, curvature, point family, needle and thread length, colour, coating and regulatory classification) before any substitution: black braided silk from Assut, Aragó, DemeTECH (SILK) and SMI (SILK). No codes from these manufacturers have been verified in public sources for the exact HR40 configuration of 40 mm, USP 2, taper point and 75 cm black thread; they must be confirmed with the manufacturer before use as a substitute or in tendering.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering. This needle geometry (HR40 Prime, USP 2, 75 cm black thread) is only safely interchangeable within the PREMISUT system itself: the direct equivalent from the same brand with identical geometry and gauge in the standard range is Ref. 542HR4002 (SKU AM542HR4002), and the double-thread presentation 2 × 75 cm is Ref. P542HR4002.2 (SKU AMP542HR4002.2).
5. Selection tips and variants of interest
- Tissue to suture: USP 2 (EP 5) gauge offers maximum tensile strength for firm subcutaneous tissue, fasciae, aponeuroses and closures under high tension or retention sutures, with a taper point needle to minimise tissue damage. For intermediate planes and smaller gauges, the same HR40 Prime family is available in USP 1 (Ref. AMP542HR4001), USP 0 (Ref. AMP542HR4010) and USP 2/0 (Ref. AMP542HR4020).
- Double presentation: if you wish to reduce the number of envelopes opened per procedure, the same HR40 Prime USP 2 configuration is available in double thread 2 × 75 cm (SKU AMP542HR4002.2).
- Prime vs. standard quality: if unit cost is a critical factor, the standard range (Ref. 542HR4002 / SKU AM542HR4002) maintains the same dimensional specifications with standard sharpening performance.
- Needle profiles: the 40 mm HR40 needle covers medium-depth access. For smaller fields, the Silk series offers HR26, HR30 and HR37 profiles; for longer travel fields, HR48 profiles, always with taper point (HR) or trocar point (HRT) depending on penetration needs. For very firm tissues, consider the reverse cutting point (DS) from the same silk range.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P542HR4002 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
- For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews