We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Non-Absorbable SILK Suture PREMISUT Prime · ½ Circle Cylindrical Body Taperpoint Taper Point Needle 40 mm (HR40) · USP 2 (EP 5) · Black Braided Thread 75 cm · Box of 12 units · Ref. P542HR4002

Original price was: 24,90 €.Current price is: 18,90 €.

Non-absorbable natural braided silk suture PREMISUT Prime (Ref. P542HR4002 · SKU AMP542HR4002): 100% silk multifilament coated with wax and silicone, with optimal glide and excellent knot security (2 = 1 = 1 = 1 technique). Mounted on a ½-circle needle, cylindrical body and 40 mm Taperpoint taper point (HR40), USP 2 gauge (metric EP 5, diameter 0.45–0.499 mm) and 75 cm black thread. Non-absorbable: gradual encapsulation with wound support for more than 3 months. Sterilised by ethylene oxide, single-use, with batch traceability. Indicated for soft tissue approximation, ligatures, skin surgery and ophthalmology. Box of 12 individual sterile envelopes; minimum order 30 boxes. Exclusive B2B sale.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP542HR4002

Description

1. Commercial Introduction

The Silk suture PREMISUT Prime is the premium reference in natural braided silk thread from Cahnos for soft tissue approximation procedures, ligatures, dermatological surgery and ophthalmology. It combines the tradition and handling of 100% natural silk (fibroin from Bombyx mori) with a Prime needle of ½ circle, cylindrical body and Taperpoint conical point of 40 mm (HR40), which passes through the tissue separating the fibres without cutting them and minimises tissue trauma. In USP 2 gauge (metric EP 5) and with a black strand of 75 cm, it offers high tensile strength and a predictable clinical knot, ideal for closures with medium-high tension. It is presented in a box of 12 sterile individual sachets, with batch traceability and stable factory reference P542HR4002.

2. Technical Explanation

The braided silk PREMISUT Prime is made up of natural protein fibres (fibroin) processed to remove natural waxes and gums, allowing a compact and uniform braid. The wax and silicone coating reduces capillarity (wicking effect), improves sliding through tissues and provides excellent knot security, with high tensile strength maintained during the critical healing period —more than three months— followed by gradual encapsulation by fibrous connective tissue. Being non-absorbable, the thread remains in the tissue providing prolonged support. The HR40 needle of 40 mm, with ½ circle curvature, cylindrical body and grooved conical point (Taperpoint), is especially suitable for soft and well-vascularised tissues (fasciae, peritoneum, muscle, mucosa and conjunctiva). The USP 2 (metric EP 5) gauge offers high tensile strength for closures with medium-high tension and retention sutures. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Brand / Quality PREMISUT Prime (premium range)
Thread material 100% natural silk (Bombyx mori fibroin), braided multifilament
Coating Wax and silicone (anti-capillary, low tissue drag)
Thread structure Braided multifilament with grooved surface
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / Size USP 2 (metric EP 5); conforming to USP and European Pharmacopoeia gauges
Approximate thread diameter 0.45 – 0.499 mm
Thread length 75 cm (free end, without loop)
Thread colour Black identifier (high visibility in surgical field)
Needle shape ½ circle (1/2 circular), cylindrical body
Tip type Conical / cylindrical (Taperpoint), grooved, non-cutting
Needle size HR 40 Prime (40 mm)
Configuration 1 needle per unit, 1 thread of 75 cm
Recommended knotting technique 2 = 1 = 1 = 1
Sterilisation Ethylene oxide (EO) – sterile
Use Single-use, sterile. Do not re-sterilise
Indications Approximation of soft tissues, ligatures, skin surgery, oral surgery and ophthalmology
Regulatory standard Complies with USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR)
Commercial presentation Box of 12 sterile individual sachets; batch traceability. Minimum order 30 boxes
Factory reference P542HR4002
Reference Cahnos (SKU) AMP542HR4002

3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
2 (this product) 5 0.45 – 0.499 mm
1 4 0.40 – 0.499 mm
0 3.5 0.35 – 0.399 mm
2/0 3 0.30 – 0.339 mm

The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their limits.

3.3. Family PREMISUT HR40 (½ circle needle of 40 mm, taperpoint conical point, black thread)

Needle profile USP size Thread Reference
HR 40 Prime 2 1 × 75 cm (black) P542HR4002 / AMP542HR4002 (this product)
HR 40 Prime 2 2 × 75 cm (black, double thread) P542HR4002.2 / AMP542HR4002.2
HR 40 standard 2 1 × 75 cm (black) 542HR4002 / AM542HR4002
HR 40 Prime 1 1 × 75 cm (black) P542HR4001 / AMP542HR4001
HR 40 Prime 0 1 × 75 cm (black) P542HR4010 / AMP542HR4010
HR 40 Prime 2/0 1 × 75 cm (black) P542HR4020 / AMP542HR4020

4. Equivalences and Cross-References

The reference P542HR4002 corresponds to the official nomenclature of the PREMISUT Prime range (HR40 profile: ½ circle needle with cylindrical body and 40 mm taperpoint conical point, USP 2 gauge, black braided thread of 75 cm) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. Non-absorbable black braided silk is one of the most standardised natural suture families on the market (commercial types Silkam® and MERSILK® / PERMA-HAND™ Silk). The following non-absorbable braided natural silk references with equivalent configuration have been compared in official catalogues and regulatory databases (GUDID); as they are another brand, they do not constitute an exact reference equivalence (reserved for the same manufacturer) and must be validated against the IFU before any substitution:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
B. Braun (Aesculap) Silkam® Black – natural braided coated silk (wax/paraffin), non-absorbable, USP 2 (EP 5), 75 cm, HR40S needle C0760560 – SILKAM BLACK 2 (5) 75CM HR40S Comparable by category (not interchangeable 1:1) Code and attributes confirmed in official B. Braun catalogue and GUDID: they match material (coated black braided silk), USP 2 (EP 5) gauge, black colour, ½ circle curvature, taper conical point, needle size of 40 mm (HR40S) and thread length of 75 cm. They differ: reinforced needle body (HR40S vs HR40 Prime), coating (wax/paraffin vs wax and silicone), sterilisation (gamma radiation vs ethylene oxide) and presentation (box of 36 units vs 12). Confirm IFU and CE/MDR classification before substituting.
Ethicon (Johnson & Johnson MedTech) MERSILK® / PERMA-HAND™ Silk – black braided silk, USP 2, 75 cm, MO-2 ½ circle needle with conical point of 40 mm W936 / W936G Comparable by category (not interchangeable 1:1) Code confirmed in Ethicon EMEA product centre and authorised distribution: they match material (natural braided silk), USP 2 (EP 5) gauge, black colour, strand length (75 cm), ½ circle curvature, conical point family and needle size (40 mm). They differ: coating (wax in Ethicon vs wax and silicone in PREMISUT Prime), designation and needle body (MO-2 vs HR40) and presentation (box of 36 sachets vs 12). Confirm IFU and CE/MDR classification before substituting.

The reference B. Braun Silkam® C0770477 (USP 2/0, 75 cm, HR40 needle) is excluded from the table because it has a smaller gauge (USP 2/0 / EP 3 vs. USP 2 / EP 5); it is not interchangeable 1:1 by gauge. Other homologous families on the market that must be reviewed property by property (material, gauge, curvature, point family, needle and thread length, colour, coating and regulatory classification) before any substitution: black braided silk from Assut, Aragó, DemeTECH (SILK) and SMI (SILK). No codes from these manufacturers have been verified in public sources for the exact HR40 configuration of 40 mm, USP 2, taper point and 75 cm black thread; they must be confirmed with the manufacturer before use as a substitute or in tendering.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering. This needle geometry (HR40 Prime, USP 2, 75 cm black thread) is only safely interchangeable within the PREMISUT system itself: the direct equivalent from the same brand with identical geometry and gauge in the standard range is Ref. 542HR4002 (SKU AM542HR4002), and the double-thread presentation 2 × 75 cm is Ref. P542HR4002.2 (SKU AMP542HR4002.2).

5. Selection tips and variants of interest

  • Tissue to suture: USP 2 (EP 5) gauge offers maximum tensile strength for firm subcutaneous tissue, fasciae, aponeuroses and closures under high tension or retention sutures, with a taper point needle to minimise tissue damage. For intermediate planes and smaller gauges, the same HR40 Prime family is available in USP 1 (Ref. AMP542HR4001), USP 0 (Ref. AMP542HR4010) and USP 2/0 (Ref. AMP542HR4020).
  • Double presentation: if you wish to reduce the number of envelopes opened per procedure, the same HR40 Prime USP 2 configuration is available in double thread 2 × 75 cm (SKU AMP542HR4002.2).
  • Prime vs. standard quality: if unit cost is a critical factor, the standard range (Ref. 542HR4002 / SKU AM542HR4002) maintains the same dimensional specifications with standard sharpening performance.
  • Needle profiles: the 40 mm HR40 needle covers medium-depth access. For smaller fields, the Silk series offers HR26, HR30 and HR37 profiles; for longer travel fields, HR48 profiles, always with taper point (HR) or trocar point (HRT) depending on penetration needs. For very firm tissues, consider the reverse cutting point (DS) from the same silk range.
  • Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P542HR4002 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
  • For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Product line

PREMISUT Prime (premium range)

Material

100% natural silk (Bombyx mori fibroin), braided multifilament

Absorption

Non-absorbable; gradual encapsulation, support for more than 3 months

USP size

USP 2 (metric EP 5)

Metric gauge (EP)

5

Approximate thread diameter

0.45 – 0.499 mm

Configuration

1 needle per unit, 1 thread of 75 cm

Sterilisation

Ethylene oxide (EO) – sterile

Use

Single-use, not re-sterilisable

Presentation

Box of 12 sterile individual sachets; minimum order 30 boxes

Manufacturer reference

P542HR4002

Indications

Approximation of soft tissues, ligatures, skin surgery, oral surgery and ophthalmology

Regulatory standard

Conforms to USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR)

Coating

Wax and silicone (anti-capillary)

Thread structure

Braided multifilament with grooved surface

Thread diameter

0.45 – 0.499 mm

Needle shape

½ circle (1/2 circular), cylindrical body

Tip type

Conical / cylindrical (Taperpoint), grooved

Needle size

HR 40 Prime (40 mm)

Swaged

1 needle per unit, 1 thread of 75 cm

Knotting technique

2 = 1 = 1 = 1

Medida de aguja

HR 40

Usp

2

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Non-Absorbable SILK Suture PREMISUT Prime · ½ Circle Cylindrical Body Taperpoint Taper Point Needle 40 mm (HR40) · USP 2 (EP 5) · Black Braided Thread 75 cm · Box of 12 units · Ref. P542HR4002”

Your email address will not be published. Required fields are marked *