Silk Suture PREMISUT Prime 4/0 Black Braided Non-Absorbable · Needle ½ Circle Triangular Point Reverse Cutting 17 mm (HS17) · Thread 75 cm · Box 12 units (Ref. P542HS1740 · SKU AMP542HS1740)

Original price was: 24,90 €.Current price is: 18,90 €.

100% natural braided silk suture, non-absorbable, from the premium PREMISUT Prime range, in USP 4/0 (metric EP 1.5). Black fluted thread of 75 cm coated with wax and silicone, mounted on a ½ circle needle with triangular reverse cutting point of 17 mm (HS17 Prime profile): clean penetration that preserves the skin edge in firm, non-distensible tissues. Gradual encapsulation with wound support exceeding 3 months; indicated for soft tissue approximation, ligatures, ophthalmology and skin surgery. Sterilised by ethylene oxide, single-use and with batch traceability. Presentation in box of 12 units in individual sachets; minimum order of 30 boxes. Factory ref. P542HS1740 · SKU Cahnos AMP542HS1740.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP542HS1740

Description

1. Commercial Introduction

The SILK Suture PREMISUT Prime is the reference in the premium range of non-absorbable sutures from Cahnos for the professional seeking a natural-origin thread with exceptional handling and predictable clinical performance. This configuration combines a black braided silk strand of USP 4/0 gauge with a ½-circle needle with triangular reverse-cutting point, 17 mm (HS17 Prime profile): the classic combination for approximating skin and soft tissues in general surgery, ophthalmology, oral and dermatological surgery.

Sterile, ready-to-use product, presented in a box of 12 units in individual sachets with batch traceability. Ideal for hospital replenishment, purchasing centres, tenders and volume contracts seeking a permanent thread with high performance and excellent value for money, with the maximum sharpening consistency of Prime quality batch after batch.

2. Technical Explanation

Silk is a natural fibrous protein (fibroin) obtained from the silkworm Bombyx mori, whose fibres are braided after removing the sericin gum and dyed black. The strand is coated with a mixture of wax and silicone that reduces capillarity, improves sliding through tissues and facilitates knotting, while maintaining excellent knot retention, one of the properties most valued by surgeons. Prime quality adds maximum sharpening precision and batch-to-batch consistency.

Being a non-absorbable suture, it does not degrade in the body: it is gradually encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical healing phase. The HS17 needle, 17 mm, features a ½-circle curvature with a triangular reverse-cutting point (reverse cutting): the edge cuts in the opposite direction to the wound bed, creating a clean entry hole that preserves the skin edge and prevents the cut from widening, facilitating passage through firm, non-distensible tissues as well as in reduced and deep surgical fields. The USP 4/0 gauge (metric EP 1.5) provides the optimal balance between fineness and strength for skin, subcutaneous tissue, mucous membranes and ligatures. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Factory reference P542HS1740 (Prime range)
Reference Cahnos (SKU) AMP542HS1740
Brand / quality PREMISUT Prime (premium range)
Thread material 100% natural silk (fibroin), braided multifilament
Thread structure Braided (multifilament), fluted finish
Coating Wax and silicone (reduced capillarity, improved sliding)
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / size USP 4/0 (metric 1.5 / EP 1.5), conforming to USP and European Pharmacopoeia gauges
Approximate thread diameter 0.15 – 0.199 mm
Thread length 75 cm (free end, without loop)
Thread colour Identification black, fluted finish (high visibility in the surgical field)
Needle shape ½ circle (1/2 circular)
Tip type Triangular reverse-cutting (Reverse Cutting), triangular body and point
Needle size HS 17 Prime (17 mm), 1 needle per thread
Swaged 1 needle / 1 suture per unit
Recommended knotting technique 2 = 1 = 1 = 1
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Indications Approximation of soft tissues, ligatures, ophthalmology and skin surgery
Commercial presentation Box of 12 units (sterile individual sachets); minimum order of 30 boxes; batch traceability
Regulatory standard Conforms to USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR)

3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
4/0 (this product) 1.5 0.15 – 0.199 mm
3/0 2 0.20 – 0.249 mm
2/0 3 0.30 – 0.339 mm

The strand diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their limits.

3.3. PREMISUT HS17 family (½ circle needle, 17 mm, reverse cutting triangular point, black braided thread)

Needle profile USP size Thread Reference
HS 17 Prime 4/0 1 × 75 cm (black) P542HS1740 / AMP542HS1740 (this product)
HS 17 Prime 3/0 1 × 75 cm (black) P542HS1730 / AMP542HS1730
HS 17 Prime 4/0 1 × 45 cm (black) P541HS1740 / AMP541HS1740
HS 17 (standard) 4/0 1 × 75 cm (black) 542HS1740 / AM542HS1740
HS 17 (standard) 3/0 1 × 75 cm (black) 542HS1730 / AM542HS1730

Reference decoding: P (Prime range) + 542 (black thread 75 cm) + HS17 (½-circle needle with 17 mm triangular reverse-cutting point) + 40 (USP 4/0 gauge). The 541 series corresponds to 45 cm thread and the 543 series to 90 cm. Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.

4. Equivalences and Cross-References

The reference P542HS1740 corresponds to the official nomenclature of the PREMISUT Prime range (HS17 profile: ½-circle needle with 17 mm triangular reverse-cutting point, USP 4/0 gauge, black 75 cm thread). Non-absorbable black braided silk is one of the most traditional permanent suture families on the market (such as PERMA-HAND, SILKAM or SOFSILK). There is no equivalence table validated by the manufacturer cross-referencing this reference with other brands; the following matches are functional, category-level comparisons, verified in the manufacturer’s official catalogue and authorised distribution, and should not be treated as 1:1 interchangeable without prior technical validation.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
B. Braun / Aesculap SILKAM® black – braided silk, 4/0 (EP 1.5), 75 cm, HR17 17 mm needle in ½ circle C0760137 (verified in official catalogue B. Braun) Comparable by category (not interchangeable 1:1) They match in material, gauge 4/0, ½-circle curvature, needle size (17 mm) and strand length; the point family differs (round-body taper point versus reverse cutting). Verify IFU before substituting.
Ethicon / J&J MedTech PERMA-HAND® Silk – black braided silk, 4-0, 75 cm, RB-1 17 mm needle in ½ circle K871H (verified in official Ethicon catalogue and authorised distribution) Comparable by category (not interchangeable 1:1) They match in material, gauge 4-0, black colour, ½-circle curvature, needle size (17 mm) and length (75 cm); the point family differs (taper point versus reverse cutting). Verify IFU before substituting.
Medtronic / Covidien SOFSILK™ – black braided silk, 4-0, 45 cm, C-1 reverse cutting needle in ⅜ circle S1274 (verified in authorised distribution) Comparable by category (not interchangeable 1:1) They match in material, gauge 4-0, colour and reverse-cutting point family; they differ in curvature (⅜ versus ½ circle) and thread length (45 versus 75 cm). Verify IFU before substituting.

Other homologous families in the segment that must be reviewed property by property (material, gauge, ½-circle curvature, reverse-cutting point family, needle length of 17 mm within ±1 mm tolerance, strand length of 75 cm, black colour, assembly of 1 needle and CE/MDR regulatory classification) before any substitution: PERMA-HAND® (Ethicon / J&J MedTech), SILKAM® (B. Braun / Aesculap), SOFSILK™ (Medtronic / Covidien), DemeSILK™ (DemeTECH) and the braided silk ranges from Serag-Wiessner. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference; no unverified cross-reference codes are published.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. This needle geometry (HS17, USP 4/0, 75 cm thread) is only fully safely interchangeable within the PREMISUT system itself: the direct equivalent within the same manufacturer, with identical geometry, gauge and length, is the standard version (Ref. 542HS1740, SKU AM542HS1740).

5. Selection tips and variants of interest

Tissue to suture: the USP 4/0 (EP 1.5) gauge is the reference size for skin, subcutaneous tissue and soft tissues with low to medium tension. The HS17 reverse cutting needle penetrates firm, non-distensible tissues without tearing the puncture bed, being indicated in general surgery, ophthalmology, oral surgery, skin surgery and ligatures. For planes of higher tension, consider USP 3/0 on the same HS17 needle (SKU AMP542HS1730); for shorter thread in reduced fields, the 45 cm presentation (SKU AMP541HS1740).

Prime quality: this reference corresponds to the Prime range, which adds maximum sharpening precision and batch-to-batch consistency compared to the standard range (Ref. 542HS1740, SKU AM542HS1740), direct equivalent within the same manufacturer with identical geometry, gauge and thread length.

Needle length and geometry: the HS17 profile of 17 mm in ½ circle covers reduced and deep fields (ophthalmology, oral surgery). For wider access, the same family is available in HS26 and HS36 profiles from the silk range, and the DS family of ⅜ circle (e.g., DS19) for wide superficial fields; for lax or well-vascularised tissues where an atraumatic needle is preferred, the same range offers the conical point version HR16 (SKU AMP542HR1630).

Sterility and storage: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P542HS1740 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team of Cahnos.

Additional information

Manufacturer reference

P542HS1740

Product line

PREMISUT Prime (premium range)

Material

100% natural silk (fibroin), braided multifilament

Coating

Wax and silicone

Absorption

Non-absorbable; gradual encapsulation, support for more than 3 months

USP size

USP 4/0 (metric 1.5 / EP 1.5)

Metric gauge (EP)

1.5 (metric EP)

Thread diameter

0.15 – 0.199 mm

Needle shape

½ circle (1/2 circular)

Needle type

Triangular reverse cutting (Reverse Cutting)

Needle size

HS 17 Prime (17 mm)

Number of needles

1 (single-armed)

Sterilisation

Ethylene oxide (EO)

Use

Single-use, not re-sterilisable

Presentation

Box of 12 units (individual sterile sachets); minimum order of 30 boxes

Minimum order

30 boxes

Indications

Approximation of soft tissues, ligatures, ophthalmology and skin surgery

Regulatory standard

Conforms to USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR)

Thread structure

Braided (multifilament), fluted finish

Tip type

Triangular reverse cutting (Reverse Cutting)

Swaged

1 needle / 1 suture per unit

Knotting technique

2 = 1 = 1 = 1

Medida de aguja

HS 17

Usp

4/0

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Estructura hilo

Braided multifilament

Reviews

There are no reviews yet.

Be the first to review “Silk Suture PREMISUT Prime 4/0 Black Braided Non-Absorbable · Needle ½ Circle Triangular Point Reverse Cutting 17 mm (HS17) · Thread 75 cm · Box 12 units (Ref. P542HS1740 · SKU AMP542HS1740)”

Your email address will not be published. Required fields are marked *