Description
The SILK Suture PREMISUT is the reference in the Cahnos range of non-absorbable sutures for the professional seeking a natural-origin thread that is manageable and offers predictable clinical behaviour. This configuration combines a braided black silk thread of USP 3/0 gauge with a 1/2 circle needle with a reverse cutting triangular point of 17 mm, the classic combination for skin and soft tissue approximation in general surgery, ophthalmology, oral surgery and dermatological surgery.
Sterile, ready-to-use product, supplied in a box of 12 units in individual pouches with batch traceability. Ideal for hospital restocking, purchasing centres, tenders and volume contracts seeking a permanent thread with an excellent quality-price ratio.
Technical product explanation
Silk is a natural fibrous protein (fibroin) obtained from the silkworm Bombyx mori, whose fibres are braided after removing the sericin gum and dyed black. The strand is coated with a mixture of wax and silicone that reduces capillary action, improves sliding through tissues and facilitates knotting, while maintaining excellent knot retention with handling properties highly valued by the surgeon.
As a non-absorbable suture, it does not degrade in the body: it is gradually encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical healing phase. The HS17 needle of 17 mm features a 1/2 circle curvature with a triangular reverse cutting point: the edge cuts in the opposite direction to the wound bed, creating a clean entry hole that preserves the skin edge and prevents the cut from widening, facilitating passage through firm, non-distensible tissues as well as in restricted and deep fields. The USP 3/0 gauge (metric EP 2) provides the optimal balance between strength and fineness for skin, subcutaneous tissue, mucous membranes and ligatures. Sterilisation by ethylene oxide (EO); single-use product, not resterilisable.
Technical specifications
3.1. General characteristics
| Parameter | Specification |
| Factory reference | 542HS1730 |
| Reference Cahnos (SKU) | AM542HS1730 |
| Brand / quality | PREMISUT (standard range) |
| Thread material | 100% natural silk (fibroin), braided multifilament |
| Coating | Wax and silicone (greater softness and sliding) |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / size | USP 3/0 (metric 2 / EP 2), conforming to USP gauges and European Pharmacopoeia |
| Approximate thread diameter | 0.20 – 0.249 mm |
| Thread length | 75 cm (free end, without loop) |
| Thread colour | Identification black, fluted finish (high visibility in the surgical field) |
| Needle shape | ½ circle (1/2 circle), fluted body |
| Tip type | Reverse cutting triangular (triangular body and point) |
| Needle size | HS 17 (17 mm), 1 needle per thread |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and skin surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets) · minimum order of 30 boxes; batch traceability |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
The strand diameter complies with the official USP Pharmacopeia ranges for non-absorbable sutures, without exceeding its limits.
3.3. PREMISUT HS17 family (½ circle needle, 17 mm, reverse cutting triangular point, black braided thread)
| Needle profile | USP size | Thread | Reference |
| HS 17 (standard) | 3/0 | 1 × 75 cm (black) | 542HS1730 / AM542HS1730 (this product) |
| HS 17 (standard) | 4/0 | 1 × 75 cm (black) | 542HS1740 / AM542HS1740 |
| HS 17 (standard) | 4/0 | 1 × 45 cm (black) | 541HS1740 / AM541HS1740 |
| HS 17 Prime | 3/0 | 1 × 75 cm (black) | P542HS1730 / AMP542HS1730 |
| HS 17 Prime | 4/0 | 1 × 75 cm (black) | P542HS1740 / AMP542HS1740 |
Reference decoding: 542 (black 75 cm thread) + HS17 (1/2 circle needle with 17 mm reverse cutting triangular point) + 30 (USP 3/0 gauge). The 541 series corresponds to 45 cm thread and the 543 to 90 cm. Cahnos markets the official reference without altering characters: no digit may be added, removed or rearranged when ordering or tendering.
Equivalences and cross-references
Reference 542HS1730 corresponds to the official nomenclature of the PREMISUT range (HS17 profile: 1/2 circle needle with 17 mm reverse cutting triangular point, USP 3/0 gauge, black 75 cm thread). Black braided non-absorbable silk is one of the most traditional permanent suture families on the market (type PERMA-HAND, SILKAM or SOFSILK).
There is no equivalence table validated by the manufacturer cross-referencing this product with other brands for the exact combination of USP 3/0 + 1/2 circle reverse cutting needle of 17 mm + black 75 cm strand. During verification in official catalogues and regulatory databases, verified codes of close configuration were found that are not interchangeable 1:1 with the HS17 profile because they differ in a critical field (point family or curvature): SILKAM® black 3/0, 75 cm, HR17 needle of 17 mm in 1/2 circle (B. Braun / Aesculap, ref. C0760145) matches in gauge, curvature, needle size and strand length, but mounts a conical round-body point (taper) instead of the reverse cutting of this product; PERMA-HAND® Silk 3-0, 75 cm, RB-1 needle of 17 mm in 1/2 circle (Ethicon / J&J MedTech, ref. K872H) also differs in conical point (taper point); and SOFSILK™ 3-0, 75 cm, black (Medtronic / Covidien, ref. SS-675) uses a C-16 needle of 3/8 circle, so the curvature differs. None of them has been included as substitutable; they must be reviewed property by property against the technical data sheet or IFU of each manufacturer before any substitution.
Homologous families in this segment that must be reviewed (material, gauge, 1/2 circle curvature, reverse cutting point family, needle length of 17 mm within ±1 mm tolerance, strand length of 75 cm, black colour, 1 needle attachment and CE/MDR regulatory classification) before any substitution: PERMA-HAND® (Ethicon / J&J MedTech), SILKAM® (B. Braun / Aesculap), SOFSILK™ (Medtronic / Covidien), DemeSILK™ (DemeTECH) and the braided silk ranges from Serag-Wiessner. The brands mentioned belong to their respective manufacturers and are mentioned only as comparative reference.
This needle geometry (HS17, USP 3/0, 75 cm thread) is only fully safely interchangeable within the PREMISUT system itself: the direct equivalent from the same manufacturer with identical geometry, gauge and length is the Prime version (Ref. P542HS1730, SKU AMP542HS1730). There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
Selection tips and variants of interest
Tissue to be sutured: the USP 3/0 (EP 2) gauge is the reference size for skin, subcutaneous tissue, mucous membranes and closures under moderate tension. The HS17 reverse cutting needle passes through firm, non-distensible tissues without tearing the puncture bed, and is indicated in general surgery, ophthalmology, oral surgery, skin surgery and ligatures. For finer planes consider the USP 4/0 with the same HS17 needle (SKU AM542HS1740 or AMP542HS1740); for shorter thread in restricted fields, the 45 cm presentation (AM541HS1740).
Prime quality: if the protocol requires maximum sharpening precision and batch-to-batch consistency, the same geometry and gauge are available in the PREMISUT Prime range (Ref. P542HS1730, SKU AMP542HS1730), a direct equivalent from the same manufacturer.
Needle length and geometry: the HS17 profile of 17 mm in ½ circle covers reduced and deep fields (ophthalmology, oral surgery). For wider access, the same family is available in HS26 and HS36 profiles from the silk range, and the DS family of ⅜ circle (e.g., DS19) for wide superficial fields; for lax or well-vascularised tissues where an atraumatic needle is preferred, the same range offers the conical point version HR16 (SKU AM542HR1630).
Sterility and storage: product sterilised by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 542HS1730 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews