Description
1. Commercial Introduction
The polypropylene suture PREMISUT PRIME with a ⅜ circular XNS needle of 19 mm is the reference choice for general surgery, plastic and cosmetic surgery, ophthalmology, neurosurgery and cardiovascular surgery departments, as well as for purchasing centres looking for a high-performance permanent suture with predictable clinical behaviour.
This reference combines an uncoated polypropylene monofilament, USP 4/0 gauge, blue thread of 75 cm and a needle with a triangular point of conventional extra-long precision cutting and a square body, designed to penetrate firm tissues with a clean cut and excellent control. Its Prime quality guarantees a homogeneous surface, low tissue reactivity and reliable knot retention. Sterile product, ready to use, presented in a box of 12 units.
2. Technical Explanation
Polypropylene is a non-absorbable synthetic polymer (polyolefin [C₃H₆]ₙ) that is presented in a monofilament structure, which reduces friction through tissue, minimises bacterial anchoring compared with multifilament sutures and does not favour the formation of sinuses in wounds at risk of contamination. As it is not absorbed or degraded by tissue enzymes, the suture undergoes gradual encapsulation by fibrous connective tissue and maintains its structural integrity for more than three months, the period in which the wound completes its critical healing phase. The blue colour guarantees optimal visibility over the surgical field.
The ⅜ circular needle XNS 19 features a triangular point with conventional extra-long precision cutting (XNS profile, conventional extra cutting) and a square body, designed for plastic, cosmetic and ophthalmic applications on firm and poorly distensible tissues —skin, muscle and scar tissue—. The square body offers greater stability in the needle holder and a controlled passage without tearing, maintaining a very balanced intermediate arc for surgical fields of medium access. The USP 4/0 configuration offers the optimal balance between fineness and strength for delicate planes. The non-grooved presentation favours a smooth and consistent delivery of the thread during knotting.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Thread material | Polypropylene (propylene polymer), uncoated monofilament, dyed blue |
| Thread structure | Monofilament, non-grooved surface |
| Absorption | Non-absorbable; gradual encapsulation without absorption (wound support for more than 3 months) |
| Thread colour | Identification blue |
| Gauge | USP 4/0 (metric EP 1.5). Conforms to USP and European Pharmacopoeia gauges. |
| Thread length | 75 cm |
| Needle shape | ⅜ circle (3/8 circular) |
| Needle type | Extra-long precision conventional cutting triangular point (XNS profile), square body |
| Needle size | XNS 19 (19 mm) |
| Manufacturing quality | Prime (premium range) |
| Tensile strength | High tensile strength; maintains integrity for more than three months |
| Sterilisation | Ethylene oxide (EO) — sterile |
| Use | Single-use; do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology, neurosurgery, oral surgery, gynaecology, orthopaedics and plastic/cosmetic surgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| References | SKU Cahnos AMP732XNS1940 / Manufacturer ref. P732XNS1940 |
4. Equivalences and Cross-References
The reference P732XNS1940 corresponds to the official nomenclature of the Premisut Prime range (XNS 19 profile, 75 cm thread). Cahnos markets the product keeping the reference without altering characters: no digit should be added, removed or reordered when ordering or bidding.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut Prime range (Cahnos) | Polypropylene XNS 19 Prime 4/0 blue 45 cm | P731XNS1940 / AMP731XNS1940 | Direct range equivalent (thread length varies) | Same XNS 19 needle, same gauge and colour; only the thread length changes (45 cm vs 75 cm). Interchangeable within the Premisut system |
| Premisut Prime range (Cahnos) | Polypropylene XNS 16 Prime 4/0 blue 75 cm | P732XNS1640 / AMP732XNS1640 | Comparable within the same system | Same 4/0 gauge and same length; XNS needle 16 mm vs 19 mm |
| Premisut Prime range (Cahnos) | Polypropylene XNS 19 Prime 5/0 blue 75 cm | P732XNS1950 / AMP732XNS1950 | Comparable within the same system | Same XNS 19 needle profile and same length; the gauge changes to USP 5/0 |
| Premisut Prime range (Cahnos) | Polypropylene XDS 19 Prime 4/0 blue 75 cm, reverse cutting | P732XDS1940 / AMP732XDS1940 | Comparable by category — not interchangeable 1:1 | Same gauge, length and 19 mm square body, but precision reverse cutting point versus conventional cutting. Verify geometry according to the tissue |
| Premisut Prime range (Cahnos) | Nylon (polyamide) XNS 19 Prime 4/0 black 75 cm | P642XNS1940 / AMP642XNS1940 | Comparable by category — not interchangeable 1:1 | Same XNS 19 needle and 4/0 gauge, but nylon (polyamide) material and black colour instead of blue polypropylene |
| Ethicon / Johnson & Johnson MedTech | PROLENE® (blue monofilament polypropylene) | Check exact reference according to gauge and needle | Comparable at category level — not interchangeable 1:1 | Blue non-absorbable polypropylene monofilament. Differences in needle geometry, commercial lengths and presentations. No official cross-reference table with the Premisut range |
| B. Braun | PREMILENE® (polypropylene monofilament) | Check specific reference | Comparable at category level — not interchangeable 1:1 | Same base material; needle geometry and presentation to be verified in official catalogue |
| Medtronic (Covidien) | Surgipro™ (polypropylene monofilament) | Check specific reference | Comparable at category level — not interchangeable 1:1 | Non-absorbable polypropylene monofilament. Verify needle, gauge and presentation against the manufacturer’s IFU |
| Serag-Wiessner | SERAPREN® (blue polypropylene monofilament) | Check specific reference | Comparable at category level — not interchangeable 1:1 | Blue non-absorbable polypropylene monofilament. Verify gauge, needle geometry and lengths with the distributor |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, PREMILENE®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tendering or substitution. This XNS needle geometry is only interchangeable within the Premisut system itself. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
Tissue to suture: the XNS needle with conventional precision cutting and square body is suitable for soft tissues, skin and plastic and cosmetic applications; for firm or poorly distensible tissues consider the XDS reverse cutting profile from the same range, and for lax or vascular tissues, round point profiles.
Gauge: USP 4/0 offers an optimal balance between fineness and strength for skin and soft tissue planes; for even finer planes (facial skin, microsurgery, ophthalmology) consider 5/0 or 6/0 from the same XNS family, and for fasciae or ligatures under higher tension, larger gauges.
Thread length: 75 cm is the usual operating theatre measure; the same XNS 19 Prime 4/0 configuration is also available with a 45 cm thread (REF. AMP731XNS1940).
XNS variants available at Cahnos: AMP731XNS1940 (19 mm, 4/0, 45 cm), AMP732XNS1950 (19 mm, 5/0, 75 cm), AMP732XNS1640 (16 mm, 4/0, 75 cm), AMP732XNS1650 (16 mm, 5/0, 75 cm) and AMP732XNS1660 (16 mm, 6/0, 75 cm), all in blue. If the protocol prefers a precision reverse cutting triangular point with square body, the reference AMP732XDS1940 is available, allowing a single supplier across the entire permanent suture portfolio.
Sterility verification: sterile product by ethylene oxide, single-use; check the integrity of the blister and the expiry date before each use. Keep the reference P732XNS1940 and the batch number for traceability in the operating theatre and in the event of a claim.





Reviews