Description
1. Commercial Introduction
The polypropylene suture PREMISUT PRIME is the reference choice in operating theatres that demand a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating tissues with total control. This presentation in USP 6/0 gauge, blue 75 cm thread and 3/8 circle XNS 16 mm needle is especially designed for very fine planes, soft tissues for approximation and specialties where every pass counts: general surgery, ophthalmology, neurosurgery, plastic and cosmetic surgery.
It is supplied sterile, ready for single use, in a box of 12 units, with batch traceability for hospital purchasing management and tenders. Available in stock at Cahnos with the factory reference P732XNS1660, kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (formula [C₃H₆]ₙ) presented as a non-coated monofilament. Lacking interstices, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinus tracts in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength permanently, exceeding the requirements of USP and European Pharmacopoeia standards, and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.
The XNS needle (3/8 circle, extra-long precision conventional cutting triangular point with a 16 mm square body) is designed to penetrate soft, non-distensible tissues with a clean, stable cut: the square body geometry provides greater stability in the needle holder and a controlled passage without tearing. The non-grooved presentation favours smooth, consistent suture delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not resterilisable.
3. Technical Specifications
| Parameter | Specification |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament, non-grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge | USP 6/0 (conforming to USP and European Pharmacopoeia gauges) |
| Thread length | 75 cm |
| Thread colour | Identification blue |
| Needle shape | ⅜ circle (3/8) |
| Needle type | Triangular point, extra-long precision conventional cutting (XNS profile) |
| Needle body / measurement | Square body, 16 mm (XNS 16 Prime profile) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology, neurosurgery, oral surgery, gynaecology, orthopaedics and plastic/cosmetic surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732XNS1660 |
| Reference Cahnos (SKU) | AMP732XNS1660 |
4. Equivalences and Cross-References
The reference P732XNS1660 corresponds to the official nomenclature of the Premisut Prime range (XNS 16 Prime profile, 75 cm suture). Cahnos markets the product keeping the reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range (Cahnos) | Polypropylene XNS 16 Prime 6/0 blue 45 cm | P731XNS1660 / AMP731XNS1660 | Direct range equivalent (thread length varies) | Same XNS 16 needle, same gauge and colour; only the suture length changes (45 cm vs 75 cm). Interchangeable within the Premisut system |
| Premisut Prime range (Cahnos) | Polypropylene XNS 16 Prime 5/0 blue 75 cm | P732XNS1650 / AMP732XNS1650 | Comparable within the same system | Same XNS 16 needle profile and same length; gauge changes to USP 5/0 |
| Premisut Prime range (Cahnos) | Polypropylene XNS 16 Prime 4/0 blue 75 cm | P732XNS1640 / AMP732XNS1640 | Comparable within the same system | Same XNS 16 needle profile and same length; the gauge changes to USP 4/0 |
| Premisut Prime range (Cahnos) | Polypropylene XNS 19 Prime 5/0 blue 75 cm | P732XNS1950 / AMP732XNS1950 | Comparable within the same system | Same material and length; XNS needle 19 mm vs 16 mm |
| Premisut Prime range (Cahnos) | Polypropylene XDS 16 Prime 6/0 blue 75 cm, reverse cutting | P732XDS1660 / AMP732XDS1660 | Comparable by category, not interchangeable 1:1 | Same gauge, length and 16 mm square body, but precision reverse cutting point instead of conventional cutting. Verify geometry according to the tissue |
| Premisut Prime range (Cahnos) | Nylon XNS 16 Prime 6/0 black 75 cm | AMP642XNS1660 | Comparable by category, not interchangeable 1:1 | Same XNS 16 needle and 6/0 gauge, but nylon (polyamide) material and black colour instead of blue polypropylene |
| Ethicon / Johnson & Johnson MedTech | PROLENE® (blue monofilament polypropylene) | Check exact reference according to gauge and needle | Comparable at category level, not interchangeable 1:1 | Blue non-absorbable polypropylene monofilament. Differences in needle geometry, commercial lengths and presentations. No official cross-reference table with the Premisut range |
| B. Braun | PREMILENE® (polypropylene monofilament) | Check specific reference | Comparable at category level, not interchangeable 1:1 | Same base material; needle geometry and presentation to be verified in official catalogue |
| Medtronic (Covidien) | Surgipro™ (polypropylene monofilament) | Check specific reference | Comparable at category level, not interchangeable 1:1 | Non-absorbable polypropylene with polyethylene monofilament. Verify needle, gauge and presentation. |
| Serag-Wiessner | SERAPREN® (blue polypropylene monofilament) | Check specific reference | Comparable at category level, not interchangeable 1:1 | Blue non-absorbable polypropylene monofilament. Verify gauge, needle geometry and lengths with the distributor |
Mandatory technical note: there is no manufacturer-validated equivalence table cross-referencing this reference with other brands; comparisons with PROLENE®, PREMILENE®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or substitution. This XNS needle geometry is only interchangeable within the Premisut system itself. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
- Tissue to suture: the XNS precision conventional cutting needle with square body is suitable for soft tissues and very fine planes (facial skin, microsurgery, ophthalmology); for firm or non-distensible tissues consider the XDS reverse cutting profile from the same range, and for lax or vascular tissues, round point profiles.
- Gauge: USP 6/0 is ideal for very fine planes and microsurgery with high tensile strength; for planes with greater mechanical demands consider 5/0 or 4/0 from the same XNS family.
- Suture length: 75 cm is the usual operating theatre measure; the same XNS 16 Prime 6/0 configuration is also available with a 45 cm suture (REF. AMP731XNS1660).
- Needle geometry: if the protocol prefers a precision reverse cutting point, the reference AMP732XDS1660 is available (XDS 16 mm, 6/0, 75 cm, blue).
- XNS variants available at Cahnos: AMP731XNS1660 (16 mm, 6/0, 45 cm), AMP732XNS1650 (16 mm, 5/0, 75 cm), AMP732XNS1640 (16 mm, 4/0, 75 cm) and AMP732XNS1950 (19 mm, 5/0, 75 cm), all in blue.
- Sterility verification: product sterile by ethylene oxide, single use; check the integrity of the blister and the expiry date before each use. Keep the reference P732XNS1660 and the batch number for traceability in the operating theatre and in case of complaint.





Reviews
There are no reviews yet.