Description
1. Commercial Introduction
The polypropylene suture Premisut Prime in a double needle 3/8 circle configuration with a 13 mm trocar point is the technical choice of professionals seeking a secure, durable closure with minimal tissue reaction in high-demand procedures. Made from high-purity polypropylene monofilament, uncoated and without grooves, it offers smooth and consistent glide through tissue, reducing surgical trauma and capillary effect.
Designed for B2B supply to hospitals, clinics, operating theatres and purchasing centres, it is supplied in a box of 12 sterile units with full traceability. Manufacturer reference P732DRT1360-2 (SKU Cahnos AMP732DRT1360-2).
2. Technical Explanation
Polypropylene is a synthetic polymer with high chemical inertness that, in monofilament form, behaves as an inert thread with a smooth surface: it exhibits no wicking effect, does not degrade by hydrolysis and becomes gradually encapsulated in tissue, maintaining wound support for more than three months. Its low memory and uniform glide facilitate secure and stable knots.
The trocar point or tapercut needle combines a cylindrical body with a cutting tip, allowing it to penetrate dense and fibrous tissues (vascular planes, aponeuroses and structures of greater consistency) with ease and precision. The double needle configuration (two needles mounted on the same thread) optimises material usage and facilitates continuous suture techniques and anastomosis without rethreading, reducing handling times and contamination risk. The USP 6/0 gauge is ideal for fine vascular anastomoses, soft tissue approximation and precision ligatures in cardiovascular surgery, ophthalmology and neurosurgery.
The product is single-use, sterilised by ethylene oxide (EtO) and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Manufacturer reference | P732DRT1360-2 |
| SKU Cahnos | AMP732DRT1360-2 |
| Material | Polypropylene monofilament (isotactic stereoisomer), uncoated |
| Thread structure | Monofilament, non-barbed, without grooves |
| Gauge | USP 6/0 (metric 0.7) |
| Approximate thread diameter | 0.070 – 0.099 mm (indicative according to USP Pharmacopoeia) |
| Thread length | 75 cm |
| Colour | Blue |
| Number of needles | 2 (double needle) |
| Needle curvature | 3/8 circle |
| Needle tip | Trocar / tapercut (cylindrical body with cutting tip) |
| Needle size | 2 x DRT 13 mm (Prime quality) |
| Absorption | Non-absorbable, gradual encapsulation |
| Sterilisation | Ethylene oxide (EtO), single-use |
| Presentation | Box of 12 sterile units |
3.2. Mechanical behaviour and clinical use
| Parameter | Value |
| Tensile strength retention | Maintained for more than 3 months (non-absorbable) |
| Tissue reaction | Minimal (inert material) |
| Sliding | Smooth and consistent, non-grooved |
| Main indications | Approximation of soft tissues, surgical ligatures, cardiovascular and vascular surgery, ophthalmology and neurosurgery |
4. Equivalences and Cross-References
Important: there is no official equivalence table validated by the manufacturer of Premisut for this reference. The references listed below are considered comparable at category level (non-absorbable monofilament polypropylene suture, blue, sterile by ethylene oxide, 3/8 13 mm needle), not interchangeable 1:1. Before a substitution in a tender or in closed clinical protocols, the type of point (trocar vs. conical vs. reverse cutting), the number of needles and the thread length must be verified in the technical data sheet or IFU of each brand.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime (Cahnos) | Polypropylene 3/8 trocar point 2xDRT13 | P732DRT1360-2 / AMP732DRT1360-2 | Original reference | Double needle 3/8 trocar 13 mm, USP 6/0, blue, 75 cm, box of 12 units. |
| Ethicon (Johnson & Johnson) | Prolene (blue polypropylene monofilament) | M8706 (6-0, C-1 13 mm, double needle, 4×30″ / 75 cm) | Functional category equivalence (very close) | Same gauge, 3/8 13 mm needle and 75 cm thread, but conical point (taper point) instead of trocar; box of 12-36 units depending on presentation. |
| Ethicon (Johnson & Johnson) | Prolene (cutting point) | 8695G (6-0, P-3 13 mm, 3/8, reverse cutting, 45 cm) | Comparable by category, not interchangeable 1:1 | Reverse cutting point, not trocar; thread of 45 cm versus 75 cm. |
| Medtronic / Covidien | Surgipro II (polypropylene monofilament) | VPF807X (6-0, blue, 30″ / 75 cm, needle KVF-1, 3/8, tapercutting) | Functional equivalence by category | Same gauge, tapercut point and 75 cm thread; single-point needle (not double needle) and presentation in box of 36 units. |
| Vitrex / Chirana (Chiralen) | Chiralen polypropylene monofilament | PP 5311 (USP 6/0, 75 cm, 2xDRT13, blue) | Functional category equivalence (very close) | Same gauge 6/0, 3/8 trocar 13 mm needle, blue 75 cm thread and double needle format; box of 24 units. Verify CE certificate. |
| B. Braun | Premilene (blue polypropylene monofilament) | C2095906 (6-0, DR13/DR13 double needle, 13 mm, 3/8, conical point, 75 cm) | Comparable by category | Same gauge, 3/8 13 mm needle and 75 cm thread, but conical taper point; confirm double needle presentation and format. |
Note: references from other manufacturers must always be cross-checked against their official source (technical data sheet, IFU or manufacturer catalogue). No equivalence table validated by the manufacturer exists; consult the technical department before use in tenders.
5. Selection tips and variants of interest
To choose the appropriate suture, always check: USP gauge, thread length, needle curvature and size, point type (conical, trocar or cutting), material and colour. The trocar point is especially indicated for dense tissues and vascular planes; if the tissue is very friable or the lumen is small, consider the conical point (taperpoint) version of the same family.
- In the Cahnos catalogue, the same reference exists in single needle: AMP732DRT1360 (6/0, DRT13, 75 cm, trocar point).
- For gauge 5/0 in double trocar needle of 13 mm: variant AMP732DRT1350-2.
- If you prefer conical point (taperpoint) in 6/0 and 13 mm double needle: variant AMP732DR1360-2.
- For coronary arteries or calcified tissue: extra smooth coronary trocar point line (DCC), ref. AMP732DCC1360-2LP.
- For 1/2 circle curve with double conical needle of 13 mm: variant AMP732HR1360-2.
Store the product in its sterile packaging, in a cool, dry place, protected from direct sunlight, and check the expiry date before use. For annual contracts, volume orders or customisation of assortments, contact the technical-commercial team of Cahnos for special B2B conditions.





Reviews
There are no reviews yet.