Description
1. Commercial Introduction
The polypropylene suture Premisut Prime in USP 6/0 gauge is the technical choice of professionals seeking a secure, durable closure with minimal tissue reaction in highly demanding procedures. Its ⅜ circle needle with trocar point (tapercut) of 13 mm, mounted on a blue monofilament thread of 75 cm, makes it a reliable solution for the approximation of soft tissues, ligatures and specialised surgeries such as cardiovascular, ophthalmology and neurosurgery.
Designed for B2B supply to hospitals, clinics, operating theatres and purchasing centres, it is supplied sterile in a box of 12 units with batch traceability. Manufacturer reference P732DRT1360 (SKU Cahnos AMP732DRT1360).
2. Technical Explanation
Polypropylene is a synthetic polymer with high chemical inertia which, in monofilament form, behaves as an inert thread with a smooth surface: it has no wicking effect, does not degrade by hydrolysis or tissue enzymes and gradually encapsulates in the tissue, maintaining wound support for more than three months. Its low memory and uniform sliding facilitate secure and stable knots.
The trocar or tapercut needle combines a cylindrical body with a cutting point: the edge opens the way and the body dilates the tissue without cutting it, allowing dense and fibrous tissues, vascular planes and aponeuroses to be traversed with ease, precision and less bleeding. The USP 6/0 gauge is ideal for fine vascular anastomoses, approximation of soft tissues and precision ligatures. The product is single-use, sterilised by ethylene oxide (EtO) and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Manufacturer reference | P732DRT1360 |
| SKU Cahnos | AMP732DRT1360 |
| Material | Polypropylene monofilament (isotactic stereoisomer), uncoated |
| Thread structure | Monofilament, non-channeled |
| Gauge | USP 6/0 (metric 0.7) |
| Approximate thread diameter | 0.070 – 0.099 mm (indicative according to USP Pharmacopoeia) |
| Thread length | 75 cm |
| Colour | Identification blue |
| Number of needles | 1 (single needle) |
| Needle curvature | ⅜ circle (3/8) |
| Needle type | Trocar / tapercut point (cylindrical body with cutting point), DRT profile |
| Needle size | DRT 13 mm (Prime quality) |
| Absorption | Non-absorbable; gradual encapsulation |
| Sterilisation | Ethylene oxide (EtO), single-use |
| Presentation | Box of 12 sterile units |
3.2. Mechanical behaviour and clinical use
| Parameter | Value |
|---|---|
| Tensile strength retention | Maintained for more than 3 months (non-absorbable) |
| Tissue reaction | Minimal (inert material) |
| Sliding | Smooth and consistent, non-grooved |
| Main indications | Approximation of soft tissues, surgical ligatures, cardiovascular and vascular surgery, ophthalmology and neurosurgery |
3.3. DRT family (⅜ circle, cylindrical body, trocar point) in fine gauges
| Needle profile | USP size | Presentation | Reference Cahnos |
|---|---|---|---|
| DRT 13 Prime | 6/0 | 1 × 75 cm | AMP732DRT1360 (analysed product) |
| 2xDRT 13 Prime | 6/0 | 2 × 75 cm | AMP732DRT1360-2 |
| DRT 13 Prime | 5/0 | 1 × 75 cm | AMP732DRT1350 |
| 2xDRT 13 Prime | 5/0 | 2 × 75 cm | AMP732DRT1350-2 |
| DRT 17 Prime | 5/0 | 1 × 75 cm | AMP732DRT1750 |
| 2xDRT 17 Prime | 5/0 | 2 × 75 cm | AMP732DRT1750-2 |
4. Equivalences and Cross-References
Important: there is no official equivalence table validated by the Premisut manufacturer that cross-references this reference with other brands. The references indicated below are considered comparable at category level (non-absorbable monofilament polypropylene suture, blue, sterile, 13 mm needle in 3/8 arc), not interchangeable 1:1. Before a substitution in tenders or closed clinical protocols, the type of point (trocar versus conical or reverse cutting), the number of needles and the presentation must be verified in the technical data sheet or IFU of each brand.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Vitrex Medical (Chiralen) | Chiralen polypropylene monofilament blue | PP 5309 | Comparable by category (not interchangeable 1:1) | Code confirmed in authorised distribution (Chiralen blue monof. USP 6/0 75 cm, DRT13 needle): same material, gauge 6/0, 3/8 trocar needle of 13 mm, 75 cm thread and blue colour. Presentation in box of 24 units; verify CE certificate and batch. |
| Vitrex Medical (Chiralen) | Chiralen polypropylene, double needle | PP 5311 | Comparable by category (not interchangeable 1:1) | Code confirmed in authorised distribution (Chiralen blue monof. USP 6/0 75 cm, 2xDRT13): same DRT13 needle, gauge 6/0 and blue 75 cm thread, in double needle format (2xDRT13) versus single needle. |
| Ethicon / Johnson & Johnson (Prolene) | Prolene blue polypropylene monofilament, C-1 needle | 8706H | Comparable by category (not interchangeable 1:1) | Code verified in official Ethicon catalogue (6-0 PROLENE blue 75 cm, C-1 needle of 13 mm, 3/8, taper point, double needle): same gauge, 3/8 needle of 13 mm and 75 cm strand, but conical point (taper point) instead of trocar and double needle configuration; box of 36 units. |
| B. Braun (Premilene / Optilene) | Premilene / Optilene polypropylene, double needle DR13 | C2095906 / G3095906 | Comparable by category (not interchangeable 1:1) | Code verified in official B. Braun catalogue and authorised distribution (Premilene 6/0, 3/8 needle of 13 mm, 75 cm): same gauge, 13 mm needle and 75 cm strand, but conical taper point and double needle format (2xDR13). |
Technical note: the reference VPF807X (Surgipro II / Medtronic-Covidien, KVF-1 needle of 13 mm) cited in some commercial comparisons could not be verified in public sources in this consultation; it should not be used as an equivalence without manufacturer confirmation. References from other manufacturers must always be checked against their official source (technical data sheet, IFU, GUDID/FDA or EUDAMED). There is no equivalence table validated by the manufacturer; consult the technical department of Cahnos before use in tenders or direct substitution.
5. Selection tips and variants of interest
To choose the appropriate suture, always check: USP gauge, strand length, needle curvature and size, point type (conical, trocar or cutting), material and colour. The trocar point is especially indicated in dense tissues and vascular planes; if the tissue is very friable or the lumen is small, consider the conical point (taperpoint) version of the same family.
In the Cahnos catalogue, the same reference in double needle configuration (2xDRT13, 6/0, 75 cm) is the variant AMP732DRT1360-2. If you prefer a conical point in 6/0 and 13 mm, you have the variant AMP732DR1360 (single needle). For gauge 5/0 with the same 13 mm trocar needle: AMP732DRT1350. For a 17 mm trocar needle in 5/0: AMP732DRT1750. For coronary arteries or calcified tissue, consult the extra smooth coronary trocar point (DCC) line of the Premisut Prime range.
Store the product in its sterile packaging, in a cool, dry place, protected from direct sunlight, and check the expiry date and the integrity of the blister before each use. For annual contracts, volume orders or customisation of assortments, contact the technical-commercial team of Cahnos for special B2B conditions.





Reviews