Description
1. Product Presentation
The Premisut Prime polypropylene suture is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour and minimal tissue reaction. This presentation in USP size 4/0, with a ⅜ circle needle, cylindrical body and 17 mm trocar point (tapercut) (DRT 17 Prime profile) and blue thread of 75 cm, is indicated for approximation of soft tissues, ligatures and high-demand procedures in general, cardiovascular, ophthalmology and neurosurgery.
It is supplied sterile and ready for individual use in a box of 12 units with batch traceability, facilitating hospital stock management and presentation to public tenders. Available at Cahnos with factory reference P732DRT1740 (SKU AMP732DRT1740), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia sizes, and is gradually encapsulated by connective tissue, helping the wound for more than three months.
The DRT 17 Prime needle (⅜ circle, cylindrical body with 17 mm Tapercut trocar point) combines the precise penetration of a sharp point with a non-cutting body that separates fibres without cutting them: it passes through dense or slightly fibrous tissues with less resistance and without cutting effect on adjacent tissue, reducing trauma and bleeding. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
The product technical specifications are listed below:
| Parameter | Specification |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Non-grooved monofilament |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 4/0 (metric EP 1.5); conforms to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm per unit |
| Thread colour | Identification blue |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle body | Cylindrical |
| Tip type | Trocar (Tapercut), DRT profile |
| Needle size | 17 mm (DRT 17 Prime) |
| Configuration | Single needle (1 × DRT) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DRT1740 |
| Reference Cahnos (SKU) | AMP732DRT1740 |
DRT 17 family (⅜ circle, cylindrical body, trocar point) within the Premisut Prime range:
| Needle profile | USP size | Presentation | Reference Cahnos |
| DRT 17 Prime | 3/0 | 1 × 75 cm | AMP732DRT1730 |
| DRT 17 Prime | 4/0 | 1 × 75 cm | AMP732DRT1740 (product analysed) |
| DRT 17 Prime | 5/0 | 1 × 75 cm | AMP732DRT1750 |
| 2xDRT 17 Prime | 4/0 | 2 × 75 cm | AMP732DRT1740-2 |
| 2xDRT 17 Prime | 5/0 | 2 × 75 cm | AMP732DRT1750-2 |
| 2xDRT 17 Prime | 4/0 | 2 × 90 cm | AMP733DRT1740-2 |
| HRT 17 Prime (½ circle, trocar point) | 4/0 | 1 × 75 cm | AMP732HRT1740 |
4. Equivalences and Cross-References
The reference P732DRT1740 corresponds to the official nomenclature of the Premisut Prime range (DRT 17 Prime profile, single needle, USP size 4/0, 75 cm thread). Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range (Cahnos) | Polypropylene DRT 17 Prime, USP 4/0, blue, 75 cm | P732DRT1740 / AMP732DRT1740 | Direct product reference | Product analysed in this data sheet |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, USP 4-0, V-4 TAPERCUT needle (17 mm ⅜ circle), blue thread 75 cm | 8942H (verified in authorised Ethicon distribution catalogue: VHHP942, V-4 needle, 3/8C, 17 mm Tapercut, 75 cm) | Functional equivalence by specifications (no official cross-reference table) | Matches in material, size, colour, length (75 cm) and needle geometry (17 mm, ⅜, trocar point); differs in packaging: box of 36 units vs 12 units |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, USP 4-0, double V-4 TAPERCUT needle 17 mm ⅜ circle, thread of 90 cm | 8925H (verified in authorised Ethicon distribution sources, box of 36 units) | Comparable by category / not interchangeable 1:1 | Same material base, size and needle; double needle and 90 cm vs single needle of 75 cm; presentation of 36 units |
| B. Braun | Premilene® – blue polypropylene monofilament, USP 4/0 (metric 1.5), 75 cm, DRT18 needle | C2090320 (verified in RevMed device database and GUDID registration 04046963632304) | Comparable by category / pending 1:1 confirmation | Same blue polypropylene base, size and length; needle designated DRT18 (≈18 mm) vs 17 mm; verify exact arc and point in the manufacturer’s technical data sheet |
| B. Braun | Optilene® – monofilament of polypropylene and polyethylene, blue | Consult code according to size and needle (C30xxxxx series) | Comparable by category, not interchangeable 1:1 | Copolymer of polypropylene with polyethylene (different material); confirm needle geometry and presentation against IFU |
| Medtronic (Covidien) | Surgipro™ II – copolymer of polypropylene with polyethylene, blue monofilament, USP 4/0, 90 cm, conical needle ½ circle | VP-521-X (verified in distribution sources: Taper Point 4-0, V-20 needle ½ circle; double-armed) | Comparable by category, not interchangeable 1:1 | Copolymer with polyethylene and conical point (not trocar) with ½ circle arc; verify needle geometry, number of needles and presentation against IFU |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | Consult order code according to size and needle (trocar profile to be verified) | Pending confirmation | Non-absorbable polypropylene with fine steel needles; confirm size, measurement and needle geometry with the distributor |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the comparisons with PROLENE®, Premilene®, Optilene®, Surgipro™ II or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Tissue to suture: the DRT trocar point needle (Tapercut) is suitable for tissues of moderate or slightly fibrous consistency that require firm penetration with minimal aggression (skin, mucosa, subcutaneous tissue, vascular planes and ophthalmology). For very friable tissues, consider conical point profiles (HR) from the same Premisut Prime range.
- Size: USP 4/0 (metric 1.5) is the usual choice for fine tissues and moderate tension; for greater support consider USP 3/0 (AMP732DRT1730) and for more delicate planes USP 5/0 (AMP732DRT1750) with the same DRT 17 needle.
- Configuration: if your protocol prefers double-needle thread (continuous or bilateral suture techniques), the same family is available in 2xDRT 17 (AMP732DRT1740-2, AMP732DRT1750-2) and in 2 × 90 cm (AMP733DRT1740-2).
- Alternative curvature: for a ½ circle arc with trocar point, reference AMP732HRT1740 is available; the choice of arc depends on the approach and the depth of the surgical field.
- Sterility verification: sterile product by ethylene oxide, single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DRT1740 and the batch number for traceability in the operating theatre and in case of complaint.





Reviews
There are no reviews yet.