Description
1. Commercial Introduction
The polypropylene suture Premisut Prime is the choice of professionals seeking a secure, durable closure with minimal tissue reaction in high-demand procedures. Its ⅜ circular needle with trocar (tapercut) point of 13 mm, mounted on a monofilament thread of USP gauge 5/0 in blue, makes it a reliable solution for approximating soft tissues, ligatures and specialised surgeries such as cardiovascular, ophthalmology, neurosurgery and microsurgery.
Designed for B2B supply to hospitals, clinics, operating theatres and purchasing centres, it is supplied sterile in a box of 12 units with batch traceability. Manufacturer reference P732DRT1350 (SKU Cahnos AMP732DRT1350).
2. Technical Explanation
Polypropylene is a synthetic polymer with high chemical inertia which, in monofilament form, behaves as an inert thread with a smooth surface: it has no wicking effect, does not degrade by hydrolysis or tissue enzymes and gradually encapsulates in the tissue, maintaining wound support for more than three months. Its low memory and uniform sliding facilitate secure and stable knots.
The trocar or tapercut needle combines a cylindrical body with a cutting tip: the edge opens the way and the body dilates the tissue without cutting it, allowing dense and fibrous tissues (vascular planes, aponeuroses and structures of greater consistency) to be traversed with ease, precision and less bleeding. The product is single-use, sterilised by ethylene oxide (EtO) and does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Manufacturer reference | P732DRT1350 |
| SKU Cahnos | AMP732DRT1350 |
| Material | Polypropylene monofilament (isotactic stereoisomer), uncoated |
| Thread structure | Monofilament, non-channeled |
| Gauge | USP 5/0 (metric 1.0 approx.) |
| Thread length | 75 cm |
| Colour | Identification blue |
| Number of needles | 1 (single needle) |
| Needle curvature | ⅜ circle (3/8) |
| Needle type | Trocar / tapercut (cylindrical body with cutting tip) |
| Needle size | DRT 13 mm (Prime quality) |
| Absorption | Non-absorbable; gradual encapsulation |
| Sterilisation | Ethylene oxide (EtO), single-use |
| Presentation | Box of 12 sterile units |
3.2. Mechanical behaviour and clinical use
| Parameter | Value |
|---|---|
| Tensile strength retention | Maintained for more than 3 months (non-absorbable) |
| Tissue reaction | Minimal (inert material) |
| Sliding | Smooth and consistent, non-grooved |
| Main indications | Approximation of soft tissues, surgical ligatures, cardiovascular and vascular surgery, ophthalmology, neurosurgery and plastic surgery |
4. Equivalences and Cross-References
Important: there is no official equivalence table validated by the manufacturer of Premisut that cross-references this reference with other brands. The references indicated below are considered comparable at category level (non-absorbable polypropylene monofilament suture, blue, sterile), not interchangeable 1:1. Before substitution in tenders or closed clinical protocols, the type of point (trocar vs. conical vs. reverse cutting), the number of needles and the strand length must be verified in the technical data sheet or IFU of each brand.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut Prime (Cahnos) | Polypropylene 3/8 trocar point DRT13 | P732DRT1350 / AMP732DRT1350 | Original reference | Single needle ⅜ trocar 13 mm, USP 5/0, blue, 75 cm, box of 12 units. |
| Premisut Prime (Cahnos) | Polypropylene 3/8 trocar point 2xDRT13 | AMP732DRT1350-2 | Configuration equivalent within the same system | Same DRT 13 needle, USP gauge 5/0, blue thread of 75 cm; double needle format instead of single needle. |
| Ethicon / Johnson & Johnson (Prolene) | Prolene polypropylene, P-3 needle | P8698T | Comparable by category, not interchangeable 1:1 | Same material, gauge 5/0 and 3/8 needle of 13 mm, but cutting point (P-3, reverse cutting) and strand of 45 cm versus 75 cm; box of 24 units. |
| Medtronic / Covidien (Surgipro II) | Surgipro II polypropylene, CV-11 needle | VP70X | Functional equivalence by category | Polypropylene monofilament, 5/0, blue, 3/8 needle of 13 mm, but conical point (taper point) and strand of 36″ (≈91 cm); single needle, box of 36 units. |
| B. Braun (Premilene) | Premilene polypropylene, double needle DR13/HR13 | C2095907 (2xDR13) / G2090954 (2xHR13) | Comparable by category | Matches in gauge 5/0, 13 mm point and 75 cm strand, but conical taper point instead of trocar, in double needle format. |
| Vitrex / Chirana (Chiralen) | Chiralen polypropylene | 4022PP 5310 | Pending confirmation | Chiralen series with DRT profile of 13 mm in fine gauges; verify in the manufacturer’s official data sheet the needle arc, format and CE certificate. |
Technical note: references from other manufacturers must always be checked against their official source (technical data sheet, IFU, GUDID/FDA or EUDAMED). There is no equivalence table validated by the manufacturer; consult the technical department of Cahnos before use in tenders.
5. Selection tips and variants of interest
To choose the appropriate suture, always check: USP gauge, strand length, curvature and needle size, point type (conical, trocar or cutting), material and colour. The trocar point is especially indicated in dense tissues and vascular planes; if the tissue is very friable or the lumen is small, consider the conical point (taperpoint) version of the same family.
- For the same DRT 13 mm profile in USP gauge 6/0: variant AMP732DRT1360.
- If you prefer a double needle with the same geometry (2xDRT13, 5/0, 75 cm): variant AMP732DRT1350-2.
- Conical point (taperpoint) in 5/0 and 13 mm: variant AMP732DR1350 (single needle).
- Trocar needle of 17 mm in 5/0: variant AMP732DRT1750.
- For coronary arteries or calcified tissue: extra smooth coronary trocar point line (DCC) from the Premisut Prime range.
Store the product in its sterile packaging, in a cool, dry place, protected from direct sunlight, and check the expiry date and the integrity of the blister before each use. For annual contracts, volume orders or customisation of assortments, contact the technical-commercial team of Cahnos for special B2B conditions.





Reviews