Description
1. Commercial Introduction
The polypropylene suture Premisut Prime in Long Pack format of 90 cm is the choice of professionals seeking a secure, durable closure with minimal tissue reaction in highly demanding procedures. Made of high-purity polypropylene monofilament, uncoated and non-grooved, it combines smooth and consistent sliding with excellent handling, reducing surgical trauma and capillary effect.
Designed for B2B supply to hospitals, clinics, operating theatres and purchasing centres, it is supplied in a box of 12 sterile units with batch traceability. Manufacturer reference P733DCC1350-2LP (SKU Cahnos AMP733DCC1350-2LP).
2. Technical Explanation
Polypropylene is a synthetic polymer with high chemical inertia which, in monofilament form, behaves as an inert thread with a smooth surface: it has no wicking effect, does not degrade by hydrolysis or tissue enzymes and gradually encapsulates in the tissue, maintaining wound support for more than three months thanks to a high sustained tensile strength. Its low memory and stable knot facilitate reliable approximation of soft tissues.
The ⅜ circular needle with cylindrical body and extra soft coronary trocar point (designation DCC, Prime quality) is designed to penetrate dense, fibrous or calcified tissues —such as the calcified coronary bed— with controlled cutting and lower resistance to passage, minimising tissue damage. The double needle configuration (2xDCC13) optimises material use and facilitates continuous suture and anastomosis techniques without rethreading. The USP 5/0 gauge (metric 1.0) is ideal for fine vascular anastomoses, approximation of soft tissues and precision ligatures. The product is single-use, sterilised by ethylene oxide (EtO) and does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Manufacturer reference | P733DCC1350-2LP |
| SKU Cahnos | AMP733DCC1350-2LP |
| Material | Polypropylene monofilament (isotactic polymer), uncoated |
| Thread structure | Monofilament, non-grooved, without grooves |
| Gauge | USP 5/0 (metric 1.0 approx.) |
| Approximate thread diameter | 0.100 – 0.149 mm (indicative per USP) |
| Thread length | 90 cm (double needle on the same thread) |
| Colour | Identification blue |
| Number of needles | 2 (double needle) |
| Needle curvature | ⅜ circle (3/8), cylindrical body |
| Needle tip | Extra smooth coronary trocar (DCC), extra smooth coronary cutting (soft cutting edge coronary) |
| Needle size | 2 × DCC 13 mm (Prime quality) |
| Absorption | Non-absorbable; gradual encapsulation |
| Sterilisation | Ethylene oxide (EtO), single-use |
| Presentation | Long Pack, box of 12 sterile units |
3.2. Mechanical behaviour and clinical use
| Parameter | Value |
|---|---|
| Tensile strength retention | Maintained for more than 3 months (non-absorbable) |
| Tissue reaction | Minimal (inert material) |
| Sliding | Smooth and consistent, non-grooved |
| Main indications | Approximation of soft tissues, surgical ligatures, cardiovascular surgery (including calcified coronary bed), ophthalmology and neurosurgery |
3.3. DCC family (⅜ circle, extra smooth coronary trocar point) in Long Pack
| Needle profile | USP size | Thread | Reference Cahnos |
|---|---|---|---|
| DCC 13 Prime | 5/0 | 1 × 75 cm | AMP732DCC1350LP |
| 2xDCC 13 Prime | 5/0 | 2 × 75 cm | AMP732DCC1350-2LP |
| 2xDCC 13 Prime | 5/0 | 2 × 90 cm | AMP733DCC1350-2LP (this product) |
| 2xDCC 13 Prime | 6/0 | 2 × 45 cm | AMP731DCC1360-2LP |
| 2xDCC 13 Prime | 6/0 | 2 × 75 cm | AMP732DCC1360-2LP |
4. Equivalences and Cross-References
Important: there is no official equivalence table validated by the manufacturer of Premisut for this reference. The references indicated below are considered comparable at category level (non-absorbable polypropylene monofilament suture, blue colour, 3/8 needle of 13 mm and USP 5/0 gauge), not interchangeable 1:1. Before a substitution in tenders or in closed clinical protocols, the type of point (extra soft coronary trocar vs. conical vs. reverse cutting), the number of needles and the thread length must be verified in the technical data sheet or IFU of each brand.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut Prime (Cahnos) | Polypropylene 3/8 extra smooth coronary trocar point DCC13, 2xDCC | P733DCC1350-2LP / AMP733DCC1350-2LP | Original reference | Double needle 3/8 extra soft coronary trocar 13 mm, USP 5/0, blue, 90 cm, Long Pack, box of 12 units. |
| Vitrex / Chirana (Chiralen) | Chiralen polypropylene monofilament | 4022 PP 5310 (USP 5/0, DRT13, 3/8 trocar, blue, 75 cm) | Functional category equivalence (very close) | Same gauge 5/0, 3/8 trocar needle of 13 mm, blue thread and monofilament; standard trocar point (not extra soft coronary) and thread of 75 cm. Box of 24 units. Verify CE certificate. |
| Ethicon / Johnson & Johnson (Prolene) | PROLENE polypropylene blue monofilament | 8890H (5/0, C-1 13 mm, 3/8, taper point, 75 cm) | Functional equivalence by category | Same gauge, 3/8 needle of 13 mm and blue thread, but conical point (taper point) instead of extra soft coronary trocar and 75 cm versus 90 cm; box of 36 units. |
| Ethicon / Johnson & Johnson (Prolene) | PROLENE polypropylene, cutting point | 8698G (5/0, P-3 13 mm, 3/8, reverse cutting, 45 cm) | Comparable by category, not interchangeable 1:1 | Reverse cutting point (reverse cutting), not trocar; thread of 45 cm versus 90 cm. |
| Medtronic / Covidien (Surgipro II) | Surgipro II polypropylene monofilament | VP-705X (5/0, CV-11 13 mm, 3/8, taper point, blue, 75 cm) | Comparable by category | Same gauge, 3/8 13 mm needle and blue thread, but taper point; presentation in box of 36 units. |
| B. Braun (Aesculap) | Premilene blue polypropylene monofilament | G2090619 (5/0, DSMP13, 13 mm, 3/8, reverse cutting micropoint, 45 cm) | Comparable by category | Reverse cutting micropoint, not coronary trocar; thread of 45 cm and presentation in box of 12 units. |
Note: references from other manufacturers must always be checked against their official source (technical data sheet, IFU, manufacturer catalogue, GUDID/FDA or EUDAMED). There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
To choose the appropriate suture, always verify: USP gauge, thread length, curvature and needle size, point type (conical, trocar or cutting), material, colour and presentation. The extra soft coronary trocar point (DCC) is especially indicated in dense tissues and in calcified coronary bed; if the tissue is very friable or the lumen is small, consider the conical point (taperpoint) version of the same family.
- Same line on the same needle and gauge 5/0 with 75 cm thread (2xDCC13 Long Pack): ref. P732DCC1350-2LP (SKU AMP732DCC1350-2LP).
- Single needle DCC13, 5/0, 75 cm Long Pack: ref. AMP732DCC1350LP.
- Double needle version in gauge 6/0 (2xDCC13, 75 cm Long Pack): ref. AMP732DCC1360-2LP.
- If you prefer standard trocar point (tapercut) in 5/0 and 13 mm: variant AMP732DRT1350-2 (double needle).
- For conical point (taperpoint) in 5/0 and 13 mm: ref. AMP732DR1350 (single needle, 75 cm).
Store the product in its sterile packaging, in a cool, dry place, protected from direct sunlight, and check the expiry date and the integrity of the blister before each use. For annual contracts, volume orders or customisation of assortments, contact the technical-commercial team of Cahnos for special B2B conditions.





Reviews