Description
1. Commercial Introduction
The polypropylene suture Premisut Prime in Long Pack format and double needle configuration is the choice of professionals and purchasing centres looking for a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction. This presentation incorporates a double ⅜ circular needle with cylindrical body and extra soft coronary trocar point of 9.3 mm (2×DCC 9.3 Prime profile), USP 6/0 gauge and blue 60 cm strand: a precision configuration designed for high-demand cardiovascular surgery, procedures on calcified coronary arteries, ophthalmology and neurosurgery.
It is supplied sterile, ready for single use, in a box of 12 units with individual sachets and full batch traceability, which facilitates hospital stock management and presentation to public tenders. Factory reference P736DCC9,360-2LP (SKU Cahnos AMP736DCC9,360-2LP), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) which, in the form of uncoated, non-grooved monofilament, behaves as an inert thread with a smooth surface: it has no wicking effect, does not promote bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. As it is non-absorbable, it is not degraded by hydrolysis or tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The ⅜ circular needle with cylindrical body and extra soft coronary trocar point (designation DCC, soft cutting edge coronary, Prime quality) is designed to penetrate dense, fibrous or calcified tissues, such as the calcified coronary bed, with controlled cutting and less resistance to passage, minimising tissue damage and the risk of tearing compared with conventional conical points. The double needle configuration (two needles mounted on the same strand) allows continuous sutures, mattress stitches and bilateral anastomoses without rethreading, reducing handling times and opening of packaging per intervention. The USP 6/0 gauge (metric 0.7) is ideal for fine vascular anastomoses and precision ligatures. Single-use product, sterilised by ethylene oxide (EO); does not allow re-sterilisation.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut Prime range (Cahnos S.L.).
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Factory reference | P736DCC9,360-2LP |
| SKU Cahnos | AMP736DCC9,360-2LP |
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament, non-channeled |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 6/0 (metric 0.7); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.070 – 0.099 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture) |
| Thread length | 60 cm |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Number of needles | 2 (double needle) |
| Needle curvature | ⅜ circle (3/8 circle), cylindrical body |
| Needle tip | Extra smooth coronary trocar (DCC), extra smooth coronary cutting (soft cutting edge coronary) |
| Needle size | 2 × DCC 9.3 mm (Prime quality) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Soft tissue approximation, ligatures, cardiovascular surgery (calcified coronary), ophthalmology and neurosurgery |
| Commercial presentation | Long Pack, box of 12 sterile units; batch traceability |
3.2. Family Premisut Prime 2×DCC 9.3 in Long Pack
| Needle profile | USP size | Thread | Reference |
|---|---|---|---|
| 2×DCC 9.3 Prime | 5/0 | 2 × 60 cm | P736DCC9,350-2LP / AMP736DCC9,350-2LP |
| 2×DCC 9.3 Prime | 6/0 | 2 × 60 cm | P736DCC9,360-2LP / AMP736DCC9,360-2LP (this product) |
| 2×DCC 9.3 Prime | 8/0 | 2 × 60 cm | P736DCC9,380-2LP / AMP736DCC9,380-2LP |
| 2×DCC 9.3 Prime | 7/0 | 2 × 45 cm | P731DCC9,370-2LP / AMP731DCC9,370-2LP |
| 2×DCC 9.3 Prime | 7/0 | 2 × 75 cm | P732DCC9,370-2LP / AMP732DCC9,370-2LP |
| 2×DCC 9.3 Prime VisiBlack | 6/0 | 2 × 75 cm (black needle) | P732DCC9,360-2VBLP / AMP732DCC9,360-2VBLP |
4. Equivalences and Cross-References
The reference P736DCC9,360-2LP corresponds to the official nomenclature of the Premisut Prime range (double needle 2×DCC 9.3 with extra soft coronary trocar point, USP 6/0 gauge, blue 60 cm thread) and is marketed in Cahnos keeping the factory reference without altering characters. Blue non-absorbable monofilament polypropylene is one of the most standardised permanent suture families on the market (commercial type ‘Prolene’). There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1 without prior technical validation against the technical data sheet or the IFU of each manufacturer.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue monofilament polypropylene, 6/0, double needle C-1 ⅜ of 13 mm, conical point | M8706 | Comparable by category (not interchangeable 1:1) | Matches material, 6/0 gauge, double ⅜ needle and blue strand; differs in conical point (taper point) versus extra soft coronary trocar, 13 mm needle versus 9.3 mm and 75 cm length versus 60 cm. Verify in official catalogue and GUDID. |
| B. Braun (Aesculap) | Premilene® – blue monofilament polypropylene, 6/0, double needle DR13 ⅜ of 13 mm, conical point | C2095906 | Comparable by category (not interchangeable 1:1) | Same material, gauge, double ⅜ needle and blue thread; conical point and 13 mm needle versus coronary trocar of 9.3 mm; length 75 cm versus 60 cm. Verify in B. Braun catalogue. |
| Medtronic (Covidien) | Surgipro™ II – blue polypropylene/polyethylene copolymer, 6/0, CV-11 ⅜ needle | VP70X / VP76X | Comparable by category (not interchangeable 1:1) | Same gauge and ⅜ geometry; copolymer material (not pure polypropylene), conical point and 13 mm needle versus coronary trocar; length 75 cm versus 60 cm. Confirm needle and size in IFU. |
| Vitrex Medical (Chiralen) | Chiralen – blue monofilament polypropylene, 6/0, double needle 2×DRT13 ⅜, standard trocar point | PP 5311 | Comparable by category (not interchangeable 1:1) | Matches 6/0 gauge, double ⅜ needle and blue thread; standard trocar point (not extra soft coronary) and 13 mm needle versus 9.3 mm; length 75 cm versus 60 cm. Verify CE certificate. |
No reference from another brand with the exact combination of 2×DCC 9.3 mm extra soft coronary trocar needle + USP 6/0 + 60 cm has been found in public sources. There is no equivalence table validated by the manufacturer; this needle geometry is only safely interchangeable within the Premisut system itself. Consult the technical department of Cahnos before use in tenders or direct substitution.
5. Selection tips and variants of interest
Tissue to suture: the USP 6/0 gauge (metric 0.7) is ideal for fine vascular anastomoses, coronary tissue and precision ligatures. The extra soft coronary trocar point (DCC) is especially indicated in dense tissues and calcified coronary bed; if the tissue is friable or very lax, consider the taper point conical version of the same Premisut range.
Variants of interest in the Cahnos catalogue: the same double needle 2×DCC 9.3 is available in 5/0 (AMP736DCC9,350-2LP), in 8/0 (AMP736DCC9,380-2LP), in 7/0 with 45 cm strands (AMP731DCC9,370-2LP) and 75 cm (AMP732DCC9,370-2LP), as well as in VisiBlack version with black needle for maximum visibility in bleeding fields (AMP732DCC9,360-2VBLP, 6/0, 75 cm) and in DCC 11 mm needle (AMP736DCC1160-2VBLP). Unifying the supplier across the entire permanent suture portfolio enables B2B volume terms.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P736DCC9,360-2LP and the batch number for traceability in the operating theatre. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.