Description
1. Commercial Introduction
The polypropylene suture Premisut Prime that Cahnos makes available to surgical departments, purchasing centres and public tenders is the reference of the permanent range when a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction is required.
This presentation incorporates a double ⅜-circle needle with a 13 mm taperpoint conical tip (2xDR13 Prime profile), USP 5/0 gauge and two 75 cm blue strands: a configuration of maximum fineness designed for approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery. It is supplied sterile, ready for individual use and with batch traceability, in a box of 12 units, facilitating the management of hospital stocks and presentation to public tenders.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) that is presented as uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion.
It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months. The blue colour ensures optimal visibility on the surgical field.
The DR13 needle (⅜ circle, cylindrical body, 13 mm taperpoint conical tip) passes through tissue separating the fibres without cutting them, which reduces trauma to delicate and vascular structures. The double-needle configuration allows continuous sutures, bilateral techniques and repositioning without rethreading, optimising surgical times. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut Prime range (Cahnos S.L.).
| Parameter | Specification |
|---|---|
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament, non-channeled |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 5/0 (metric EP 1.0); conforming to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.100 – 0.149 mm (according to USP Pharmacopeia, synthetic non-absorbable suture) |
| Thread length | 2 threads of 75 cm (2 × 75 cm) per unit |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle body | Cylindrical |
| Tip type | Conical taperpoint (DR profile) |
| Needle size | 13 mm – double needle presentation (2xDR13 Prime) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P732DR1350-2 |
| Reference Cahnos (SKU) | AMP732DR1350-2 |
Family Premisut Prime 2xDR13 (double ⅜ circle needle, taperpoint conical point, blue)
| Needle profile | USP size | Thread | Reference |
|---|---|---|---|
| 2xDR13 Prime | 5/0 | 45 cm | P731DR1350-2 / AMP731DR1350-2 |
| 2xDR13 Prime | 5/0 | 60 cm | P736DR1350-2 / AMP736DR1350-2 |
| 2xDR13 Prime | 5/0 | 75 cm | P732DR1350-2 / AMP732DR1350-2 (this product) |
| 2xDR13 Prime | 5/0 | 90 cm | P733DR1350-2 / AMP733DR1350-2 |
| 2xDR13 Prime | 4/0 | 90 cm | P733DR1340-2 / AMP733DR1340-2 |
| 2xDR17 Prime | 5/0 | 90 cm | P733DR1750-2 / AMP733DR1750-2 |
4. Equivalences and Cross-References
The reference P732DR1350-2 corresponds to the official nomenclature of the Premisut Prime range (double DR13 taperpoint needle of 13 mm, USP 5/0 gauge, 75 cm blue thread) and is marketed by Cahnos keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or the IFU of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene 2xDR13 Prime, USP 5/0, blue, 45 cm | P731DR1350-2 / AMP731DR1350-2 | Direct range equivalent | Same needle, quality, gauge and colour; length of 45 cm versus 75 cm |
| Cahnos (Premisut Prime) | Polypropylene 2xDR13 Prime, USP 5/0, blue, 60 cm | P736DR1350-2 / AMP736DR1350-2 | Direct range equivalent | Same needle, quality, gauge and colour; length of 60 cm versus 75 cm |
| Cahnos (Premisut Prime) | Polypropylene 2xDR13 Prime, USP 5/0, blue, 90 cm | P733DR1350-2 / AMP733DR1350-2 | Direct range equivalent | Same needle, quality, gauge and colour; length of 90 cm versus 75 cm |
| Cahnos (Premisut Prime) | Polypropylene DR13 Prime, USP 5/0, blue, 75 cm (single needle) | AMP732DR1350 | Configuration equivalent within the same system | Same DR13 needle, gauge and length; changes to a single thread of 75 cm (1 × 75 cm) |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 5/0, double C-1/C-1 ⅜ circle taperpoint needle 13 mm | 8717H (45 cm presentation) | Comparable by category, not interchangeable 1:1 | Code verified in authorised Ethicon distribution: same material, gauge, colour, radius, tip and configuration; presentation of 45 cm versus 2 × 75 cm of this data sheet. Confirm CE/MDR traceability against IFU |
| Medtronic (Covidien) | Surgipro™ II – polypropylene/polyethylene copolymer, 5/0, blue, double CV-22 ⅜ circle taperpoint needle 13 mm | VP715X / VP715X-2 | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution: same needle configuration and gauge; copolymer material (not pure polypropylene) and presentation of 45 cm. Confirm exact geometry in IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 5/0, ⅜ taperpoint DR needle | Not verified in this consultation | Comparable by category, not verified | Same base material and family confirmed; confirm exact reference, needle and presentation in official catalogue before use |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | Not verified in this consultation | Comparable by category, not verified | Same base material; confirm code, needle and presentation in official catalogue before use |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Surgipro™ II, Premilene® or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. This needle geometry (2xDR13 taperpoint, 5/0, 75 cm) is only interchangeable with full safety within the Premisut system itself. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: the taperpoint conical needle separates the fibres without cutting them, ideal for lax, vascular and well-irrigated soft tissues (cardiovascular, ophthalmology, neurosurgery). The USP 5/0 gauge (metric 1.0) offers the balance between fineness and strength for delicate planes; if the protocol requires greater fineness, consider USP 6/0 or USP 7/0 within the Prime range.
Length and presentation: this double-needle 75 cm reference is the balanced option of the family, designed for continuous sutures, anastomoses and medium-length passes. For greater thread length while keeping the same needle, the 90 cm variant is available (AMP733DR1350-2); if you are looking for a more compact and economical presentation, the 45 cm (AMP731DR1350-2) or the 60 cm (AMP736DR1350-2).
Other variants of interest: the same double DR13 needle in 4/0 gauge (AMP733DR1340-2), the DR17 needle with greater length (AMP733DR1750-2), the single-needle DR13 5/0 75 cm presentation (AMP732DR1350) to reduce cost per unit, or the ½-circle variant with conical tip HR13 (AMP732HR1350-2) when a different needle radius is required.
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DR1350-2 and the batch number for traceability in the operating theatre. For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews