Description
1. Commercial Introduction
The Premisut Prime polypropylene suture in double-needle presentation is the choice of the professional who needs a high-performance non-absorbable thread for surgical planes of maximum fineness. This reference combines an uncoated polypropylene monofilament, dyed in high-visibility blue, with two ⅜-circle needles, cylindrical body and 13 mm Taperpoint conical point (2xDR 13 Prime profile), in USP 7/0 gauge and two 60 cm threads: an extremely precise configuration designed for soft tissue approximation, ligatures, cardiovascular surgery, ophthalmology and neurosurgery.
Sterile, single-use product with batch traceability, presented in a box of 12 units in individual pouches, it is ideal for surgical services, purchasing centres, public tenders and hospital supply agreements that value consistent quality and excellent value for money. It is marketed under the factory reference P736DR1370-2 (SKU Cahnos AMP736DR1370-2), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) that is presented as an uncoated, non-grooved monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adhesion or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The ⅜-circle needle with cylindrical body and 13 mm Taperpoint conical point passes through the tissue separating the fibres without cutting them, which reduces trauma to delicate and vascular structures. The double-needle configuration allows continuous sutures to be performed or the strand to be repositioned without rethreading, reducing the opening of packaging per procedure. The USP 7/0 gauge (EP metric 0.5) is one of the finest in the Premisut Prime range, designed for precision sutures in microsurgery. Sterilisation is carried out by ethylene oxide (EO); the product is single-use and not resterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut Prime range (Cahnos S.L.).
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue (≥ 99.5% polypropylene, ≤ 0.5% phthalocyanine blue) |
| Thread structure | Non-grooved monofilament |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 7/0 (metric EP 0.5); conforming to USP gauges and European Pharmacopoeia |
| Thread diameter | 0.050 – 0.069 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture) |
| Thread length | 2 × 60 cm per unit (double needle) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Taperpoint conical point (cylindrical body) |
| Needle size | 13 mm (2xDR 13 Prime profile) |
| Configuration | Double needle: 2 needles with 2 threads of 60 cm |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P736DR1370-2 |
| Reference Cahnos (SKU) | AMP736DR1370-2 |
Family Premisut Prime 2xDR 13 (double needle ⅜ circular, cylindrical body, Taperpoint conical point, blue thread):
| Needle profile | USP size | Thread | Reference |
| 2xDR 13 Prime | 7/0 | 2 × 60 cm (double needle) | P736DR1370-2 / AMP736DR1370-2 (this product) |
| 2xDR 13 Prime | 7/0 | 2 × 75 cm (double needle) | P732DR1370-2 / AMP732DR1370-2 |
| 2xDR 13 Prime | 6/0 | 2 × 60 cm (double needle) | P736DR1360-2 / AMP736DR1360-2 |
| 2xDR 13 Prime | 6/0 | 2 × 75 cm (double needle) | P732DR1360-2 / AMP732DR1360-2 |
| 2xDR 13 Prime | 5/0 | 2 × 45 cm (double needle) | P731DR1350-2 / AMP731DR1350-2 |
| 2xDR 13 Prime | 5/0 | 2 × 60 cm (double needle) | P736DR1350-2 / AMP736DR1350-2 |
| 2xDR 13 Prime | 5/0 | 2 × 75 cm (double needle) | P732DR1350-2 / AMP732DR1350-2 |
| 2xDR 13 Prime | 4/0 | 2 × 90 cm (double needle) | P733DR1340-2 / AMP733DR1340-2 |
| DR 13 Prime | 6/0 | 1 × 75 cm (single needle) | P732DR1360 / AMP732DR1360 |
| DR 13 Prime | 5/0 | 1 × 75 cm (single needle) | P732DR1350 / AMP732DR1350 |
4. Equivalences and Cross-References
Reference P736DR1370-2 corresponds to the official nomenclature of the Premisut Prime range (2xDR 13 profile, double needle with 13 mm Taperpoint conical point, USP 7/0 gauge, blue thread 2 × 60 cm) and is marketed by Cahnos keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or the IFU of each manufacturer before use in tenders or direct substitution. Consult the Cahnos technical department to validate any equivalence.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene 2xDR 13 Prime, USP 7/0, blue, 2 × 60 cm | P736DR1370-2 / AMP736DR1370-2 | Reference of the analysed product | This data sheet; double needle and double thread of 60 cm |
| Cahnos (Premisut Prime) | Polypropylene 2xDR 13 Prime, USP 7/0, blue, 2 × 75 cm | P732DR1370-2 / AMP732DR1370-2 | Direct range equivalent | Same DR 13 needle, quality, gauge and colour; 75 cm thread versus 60 cm |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 7/0, double needle C-1 ⅜ circle taper point 13 mm, 75 cm | 8708H / EP8708H | Comparable by category, not interchangeable 1:1 | Code verified in Ethicon catalogue and authorised distribution: material, gauge, colour, radius, 13 mm taper point and 75 cm length match; pack of 36 units versus box of 12; confirm CE/MDR traceability against IFU |
| Medtronic (Covidien) | Surgipro™ II – blue polypropylene/polyethylene copolymer, 7/0, double needle CV-11 ⅜ circle taper point 13 mm, 45 cm | VP800X / VP800X-2 | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution: same clinical indication, gauge and 13 mm needle geometry; copolymer material (not pure polypropylene) and 45 cm versus 2 × 60 cm; confirm radius and exact point against IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 7/0 | 7/0 code not verified in this consultation | Comparable by category, not verified | Same base material and family confirmed in official catalogue; confirm exact reference, needle and presentation before use |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | Pending confirmation of 7/0 code | Not verified | Same base material; confirm code, needle and presentation in official catalogue before use |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Surgipro™ II, Premilene® or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or the IFU of each manufacturer before use in tenders or direct substitution. This needle geometry (2xDR 13 Taperpoint, USP 7/0, 2 × 60 cm) is only safely interchangeable within the Premisut system itself.
5. Selection tips and variants of interest
Tissue to suture: the USP 7/0 gauge (EP metric 0.5) is one of the finest in the range, indicated for microsurgery and very delicate planes (ophthalmology, neurosurgery, cardiovascular surgery) and thin skin. The Taperpoint conical needle separates the fibres without cutting them, ideal for lax, vascular and well-irrigated tissues; for firm or poorly distensible tissues, consider reverse cutting profiles from the same Premisut range.
Presentation: the double-needle version of this data sheet reduces the opening of packaging per procedure and provides two 60 cm threads for continuous sutures or repositioning without rethreading; if the protocol requires more thread length, reference P732DR1370-2 (AMP732DR1370-2) offers the same profile with 2 × 75 cm, and if a single needle is sought, the DR 13 Prime 6/0 75 cm (AMP732DR1360) is a more economical option per unit for occasional uses.
Variants of the same DR 13 needle: USP 7/0 in 75 cm (AMP732DR1370-2), USP 6/0 in 60 cm (AMP736DR1360-2) and 75 cm (AMP732DR1360-2), USP 5/0 in 45, 60 and 75 cm (AMP731DR1350-2, AMP736DR1350-2, AMP732DR1350-2) and USP 4/0 in 90 cm (AMP733DR1340-2), which allows unifying supplier across the entire permanent suture portfolio. Other geometries: DR 17 needle (AMP733DR1750-2), trocar point DRT 13 (AMP732DRT1360-2) or ½ circle variant with HR 13 conical point (AMP736HR1360-2, AMP736HR1350-2).
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep reference P736DR1370-2 and the batch number for traceability in the operating theatre and in case of complaint. For special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team of Cahnos.





Reviews