Description
1. Product Presentation
The Premisut Prime polypropylene suture that Cahnos offers is the reference choice for surgery departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating tissue with total control. This presentation in USP 3/0 calibre, with a ⅜ circle needle of 40 mm, triangular reverse cutting grooved point and a 75 cm blue thread, is indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
It is supplied sterile, ready for single use, in a box of 12 units with batch traceability, facilitating hospital stock management and presentation for public tenders. Available under the factory reference P732DS4030 (SKU AMP732DS4030), kept without altering characters: no digit may be added, removed or reordered when ordering or bidding.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period in accordance with USP and European Pharmacopoeia calibres, and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.
The DS 40 Prime needle (⅜ circle, triangular reverse cutting grooved point of 40 mm) penetrates soft and poorly distensible tissues with a clean, stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage. The grooved finish of the needle body and thread facilitates smooth, consistent delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / Quality | Premisut Prime (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 3/0 (EP metric 2); conforms to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue (high visibility in the field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting grooved point (DS profile) |
| Needle size | 40 mm (DS 40 Prime profile) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DS4030 |
| Reference Cahnos (SKU) | AMP732DS4030 |
Family Premisut Prime DS 40 (⅜ circle needle, triangular reverse cutting grooved point, blue):
| USP size | Thread | Reference |
|---|---|---|
| 3/0 | 1 × 75 cm | P732DS4030 (AMP732DS4030) – this product |
| 3/0 | 2 × 75 cm | P732RDS4030.2 (AMP732RDS4030.2) |
| 2/0 | 1 × 75 cm | P732DS4020 (AMP732DS4020) |
| 2/0 | 2 × 75 cm | P732RDS4020.2 (AMP732RDS4020.2) |
| 0 | 1 × 75 cm | P732DS4010 (AMP732DS4010) |
4. Equivalences and Cross-References
The reference P732DS4030 corresponds to the official nomenclature of the Premisut Prime range (DS 40 Prime profile, single 75 cm thread). There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution. Third-party codes included in this table have been verified against the official catalogue or authorised distribution sources.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene DS 40 Prime, USP 3/0, blue, 1 × 75 cm | P732DS4030 / AMP732DS4030 | Product reference | Product analysed in this data sheet |
| Cahnos (Premisut Prime) | Polypropylene DS 40 Prime, USP 3/0, blue, 2 × 75 cm | P732RDS4030.2 / AMP732RDS4030.2 | Direct range equivalent (presentation varies) | Same DS 40 needle, calibre, colour and quality; 2 threads of 75 cm per unit versus 1 thread |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® blue polypropylene monofilament, FSLX 40 mm needle, 3/8 circle, reverse cutting | 8649H | Functional equivalence by specifications (no official cross-reference table) | Code verified in authorised distribution sources: blue polypropylene monofilament 3/0, 75 cm, 3/8 circle reverse cutting needle of 40 mm (FSLX); matches in calibre, length, colour and needle geometry. Commercial presentation in box of 36 units; confirm batch and CE/MDR traceability against IFU |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® polypropylene, KS straight cutting needle (straight cutting), 60 mm | 8622H | Comparable by category, not interchangeable 1:1 | Code verified in Ethicon catalogue: same calibre 3/0, blue 75 cm thread and material, but straight KS needle of 60 mm (not curved ⅜ circle of 40 mm); needle geometry not equivalent for deep surgery. Check technique and tissue before substituting |
| B. Braun (Aesculap) | Premilene® blue polypropylene monofilament, DS30 needle (reverse cutting) | C0090246 (3/0, 75 cm, DS30) | Comparable by category, not interchangeable 1:1 | Code verified in catalogue/distribution sources: same base material, calibre and length, but DS30 needle of 30 mm versus DS 40 of 40 mm; confirm exact needle geometry in official B. Braun catalogue |
| Medtronic (Covidien) | Surgipro™ II (polypropylene + polyethylene copolymer), blue | SP-675 (C-16 needle, 3/8, reverse cutting) | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution sources: polypropylene copolymer with polyethylene in blue calibre 3/0 and 75 cm, but C-16 needle of smaller size than DS 40; confirm reference and batch against IFU |
| Serag-Wiessner | SERAPREN® blue polypropylene monofilament, DS-30 reverse cutting needle | CO203416 (3/0, 75 cm, DS-30) | Comparable by category, not interchangeable 1:1 | Code verified in official SERAPREN catalogue: blue polypropylene monofilament 3/0 of 75 cm with DS-30 needle; needle of 30 mm versus 40 mm. Correction note: the code CO353416 cited in other tables corresponds to USP 0 with DS-30 (not 3/0), according to official Serag-Wiessner listing |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or substitution. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
- Tissue to suture: the DS reverse cutting grooved needle is suitable for soft and flat skin tissues requiring firm and controlled penetration (cardiovascular surgery, ophthalmology, neurosurgery and general surgery). For lax or vascular tissues, consider round point profiles (HR) from the same Premisut Prime range.
- Needle size: the 40 mm DS is a generously long needle, indicated for wide suture planes or access to deep tissue; for smaller areas, the DS 30 (AMP732DS3030) and DS 19 (AMP732DS1930) variants are available in the same USP 3/0 gauge and 75 cm length.
- Double vs. single presentation: the 2 × 75 cm version (AMP732RDS4030.2) reduces the opening of packages per procedure when the protocol requires several passes or continuous sutures.
- Gauge: USP 3/0 is versatile for soft tissues and medium-tension ligatures; for higher-tension planes, consider USP 0 (AMP732DS4010) and for a smaller gauge USP 2/0 (AMP732DS4020) with the same DS 40 needle.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use. Keep the reference P732DS4030 and the batch number for traceability in the operating theatre and in case of a claim.





Reviews