Description
1. Commercial Introduction
The polypropylene suture PREMISUT PRIME that Cahnos makes available to surgical services, purchasing centres and tenders is the reference choice when a non-absorbable suture with predictable behaviour, excellent handling and minimal tissue reaction is required. This presentation incorporates a ⅜ circle needle with a triangular reverse cutting grooved point of 30 mm (DS 30 Prime profile), USP 3/0 gauge and two 75 cm strands in high-visibility blue: a versatile configuration, widely used in soft tissues, ligatures and procedures in cardiovascular surgery, ophthalmology, neurosurgery and general surgery. The product is supplied sterile, ready for single use, in a box of 12 units with batch traceability, facilitating hospital stock management and presentation for public tender.
2. Technical explanation
Polypropylene is a synthetic linear polyolefin that is presented as uncoated monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The DS 30 Prime needle (⅜ circle, triangular reverse cutting grooved point of 30 mm) penetrates soft and poorly distensible tissues with a clean and stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage. The grooved finish of the needle body facilitates smooth and consistent delivery during knotting. The presentation of two threads per package reduces the opening of blisters when the protocol requires several passes or a continuous suture. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge | USP 3/0 (EP metric 2); conforms to USP and European Pharmacopoeia gauges |
| Thread length | 2 threads of 75 cm (2 × 75 cm) per unit |
| Thread colour | Identification blue (high visibility in the field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting grooved point (DS profile) |
| Needle size | 30 mm (DS 30 Prime profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DS3030.2 |
| Reference Cahnos (SKU) | AMP732DS3030.2 |
Family Premisut Prime DS 30 (⅜ circle needle, triangular reverse cutting grooved point, blue):
| Needle profile | USP size | Presentation | Reference |
| DS 30 Prime | 3/0 | 2 × 75 cm | P732DS3030.2 (this product) |
| DS 30 Prime | 3/0 | 1 × 75 cm | P732DS3030 |
| DS 30 Prime | 2/0 | 1 × 75 cm | P732DS3020 |
| DS 30 Prime | 0 | 2 × 75 cm | P732DS3010.2 |
4. Equivalences and Cross-References
The reference P732DS3030.2 corresponds to the official nomenclature of the Premisut Prime range (DS 30 Prime profile, double 75 cm thread). Cahnos markets the product keeping the factory reference unchanged: no digit may be added, removed or reordered when ordering or tendering. The DS needle profile (reverse cutting) is interchangeable within the Premisut system itself, varying only the needle size or gauge.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range (Cahnos) | Polypropylene DS 30 Prime, USP 3/0, blue, 2 × 75 cm | P732DS3030.2 / AMP732DS3030.2 | Direct product reference | Product analysed in this data sheet |
| Premisut Prime range (Cahnos) | Polypropylene DS 30 Prime, USP 3/0, blue, 1 × 75 cm | P732DS3030 / AMP732DS3030 | Configuration equivalent within the same system | Same DS 30 needle and USP 3/0 gauge; the presentation changes to 1 thread of 75 cm |
| Premisut (Cahnos) | Polypropylene DS 30, USP 3/0, blue, 75 cm (standard quality) | AM732DS3030 (REF. 732DS3030) | Functional category equivalent | Same geometry, gauge and length; standard quality, needle without grooved body |
| Premisut Prime range (Cahnos) | Polypropylene DS 36 Prime, USP 3/0, blue, 2 × 75 cm | AMP732DS3630.2 | Comparable within the same system | Same gauge and presentation; DS needle of 36 mm versus 30 mm |
| Ethicon (Johnson & Johnson MedTech) | PROLENE – blue polypropylene monofilament, USP 3/0, 75 cm, FSLX 3/8 circle reverse cutting needle | 8649H | Functional equivalence by specifications (no official cross-reference table) | Code verified in authorised distribution sources: it matches in material, gauge, colour, length and 3/8 reverse cutting needle geometry, although the FSLX size is 40 mm versus 30 mm. Presentation in a box of 36 units; confirm batch and CE/MDR traceability against the IFU |
| B. Braun (Aesculap) | Premilene – blue monofilament polypropylene, DS30 needle (reverse cutting) | C0090246 (3/0, 75 cm, DS30) | Comparable by category, not interchangeable 1:1 | Code verified in official catalogue: same base material, gauge and length with DS 30 mm needle; confirm exact needle geometry and presentation in official B. Braun catalogue |
| Medtronic (Covidien) | Surgipro II – polypropylene copolymer with polyethylene, blue | SP-675 (C-16 needle, 3/8, reverse cutting) | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution sources: copolymer (not pure polypropylene) in blue 3/0 gauge and 75 cm; confirm reference and batch against the IFU |
| Serag-Wiessner | SERAPREN – blue polypropylene monofilament, DS-30 needle | CO203416 (3/0, 75 cm, DS-30) | Comparable by category, not interchangeable 1:1 | Code verified in official SERAPREN catalogue: blue polypropylene monofilament 3/0 of 75 cm with DS-30 needle; verify batch and presentation |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE, Premilene, Surgipro or SERAPREN are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution. Consult Cahnos’s technical department to validate any equivalence before use.
5. Selection tips and variants of interest
Tissue to suture: the grooved reverse cutting DS needle is suitable for soft tissues and skin planes that require firm and controlled penetration (cardiovascular surgery, ophthalmology, neurosurgery and general surgery). For lax or vascular tissues, consider round point profiles from the same Premisut Prime range.
Needle size: the DS 30 is an intermediate needle, ideal for medium suture planes and areas with reduced access; for wider fields, the DS 36 (AMP732DS3630.2) or DS 40 (AMP732RDS4030.2) is available in the same gauge, and for more superficial planes the DS 24 (AMP732DS2430.2) or DS 19 (AMP732DS1930.2).
Gauge: USP 3/0 (metric 2) is versatile for soft tissues and medium-tension ligatures; for greater mechanical demand, consider USP 0 (AMP732DS3010.2) with the same DS 30 needle.
Presentation: the 2 × 75 cm version reduces the opening of packages per intervention compared to the single-thread version (AMP732DS3030); if you prefer an economical alternative, the standard Premisut quality (AM732DS3030) maintains the same needle and configuration.
Sterility verification: single-use product sterilised by ethylene oxide; check the blister integrity and expiry date before each use and keep the reference P732DS3030.2 and the batch number for traceability in the operating theatre and in the event of a claim. For B2B volume conditions, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews