Description
1. Commercial Introduction
The Premisut Prime polypropylene suture is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable suture with predictable behaviour, excellent handling and minimal tissue reaction. This presentation incorporates a ⅜ circle needle with a grooved reverse cutting triangular point of 19 mm (DS 19 Prime profile), USP 2/0 gauge and two 75 cm strands in high-visibility blue: a versatile configuration widely used in soft tissues, ligatures and cardiovascular surgery, ophthalmology, neurosurgery and general surgery procedures. The product is supplied sterile, ready for single use, in a box of 12 units with batch traceability, facilitating hospital stock management and presentation for public tender. Cahnos markets this reference under the factory code P732DS1920.2 (SKU AMP732DS1920.2), without altering any character of the original nomenclature.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: lacking interstices and wick effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The DS 19 Prime needle (⅜ circle, grooved reverse cutting triangular point of 19 mm) penetrates soft and poorly distensible tissues with a clean and stable cut: the reverse cutting geometry supports the edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage. The grooved finish of the needle facilitates smooth and consistent delivery during knotting. The presentation of two threads per package reduces the opening of blisters when the protocol requires several passes or a continuous suture. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Property | Specification |
| Brand / Quality | Premisut Prime (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge | USP 2/0 (metric EP 3); conforming to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.30 – 0.349 mm (according to USP Pharmacopeia) |
| Thread length | 2 threads of 75 cm (2 × 75 cm) per unit |
| Thread colour | Identification blue (high visibility in the field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting grooved point (DS profile) |
| Needle size | 19 mm (DS 19 Prime profile) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DS1920.2 |
| Reference Cahnos (SKU) | AMP732DS1920.2 |
Family Premisut Prime DS 19 (⅜ circle needle, grooved reverse cutting triangular point, blue):
| Needle profile | USP size | Presentation | Reference |
| DS 19 Prime | 2/0 | 2 × 75 cm | P732DS1920.2 (this product) |
| DS 19 Prime | 2/0 | 1 × 75 cm | P732DS1920 |
| DS 19 Prime | 3/0 | 2 × 75 cm | P732DS1930.2 |
| DS 19 Prime | 3/0 | 1 × 75 cm | P732DS1930 |
| DS 19 Prime | 4/0 | 1 × 75 cm | P732DS1940 |
| DS 19 Prime | 6/0 | 1 × 75 cm | P732DS1960 |
4. Equivalences and Cross-References
The reference P732DS1920.2 corresponds to the official nomenclature of the Premisut Prime range (DS 19 Prime profile, double 75 cm thread). Cahnos markets the product keeping the factory reference without altering characters: no digit should be added, removed or reordered when ordering or tendering. The DS needle profile (reverse cutting) is interchangeable within the Premisut system itself, varying only the needle size or gauge.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range (Cahnos) | Polypropylene DS 19 Prime, USP 2/0, blue, 2 × 75 cm | P732DS1920.2 / AMP732DS1920.2 | Direct product reference | Product analysed in this data sheet |
| Premisut Prime range (Cahnos) | Polypropylene DS 19 Prime, USP 2/0, blue, 1 × 75 cm | AMP732DS1920 | Configuration equivalent within the same system | Same DS 19 needle and USP 2/0 gauge; the presentation changes to 1 thread of 75 cm |
| Premisut (Cahnos — standard quality) | Polypropylene DS 19, USP 2/0, blue, 75 cm | AM732DS1920 | Functional category equivalent | Same needle geometry, gauge and length; standard quality, needle without Prime grooved body. |
| Ethicon (Johnson & Johnson MedTech) | PROLENE – blue polypropylene monofilament, USP 2/0, 75 cm, FSLX 3/8 circle reverse cutting needle. | 8689H | Functional equivalence by specifications (no official cross-reference table) | Code verified in Ethicon catalogue and authorised distribution sources: matches in material, gauge, colour and length; FSLX needle of larger size (40 mm) compared to DS 19. Presentation in box of 36 units; confirm batch and traceability against the IFU. |
| B. Braun (Aesculap) | Premilene – blue polypropylene monofilament, 2/0 (EP 3), 75 cm, DS19 needle. | C2095522 | Comparable by category, not interchangeable 1:1 | Code verified in official B. Braun catalogue: same base material, gauge and DS needle of 19 mm; confirm exact needle geometry and presentation in official data sheet. |
| B. Braun (Aesculap) | Optilene – copolymer of polypropylene and polyethylene, blue, 2/0, 75 cm, DS19 needle. | C3095522 | Comparable by category, not interchangeable 1:1 | Code verified in official B. Braun catalogue: copolymer (not pure polypropylene) with DS19 needle of 19 mm; verify IFU and presentation. |
| Medtronic (Covidien) | Surgipro II – copolymer of polypropylene with polyethylene, blue, 2/0, 75 cm, C-15 3/8 circle reverse cutting needle. | SP685 | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution sources: copolymer in blue 2/0 gauge and 75 cm with reverse cutting needle; confirm reference and batch against the IFU. |
| Serag-Wiessner | SERAPREN – blue polypropylene monofilament, 2/0, 75 cm, DS-21 needle. | CO303497 | Comparable by category, not interchangeable 1:1 | Code verified in official SERAPREN catalogue: blue 2/0 monofilament polypropylene of 75 cm with DS-21 needle (21 mm); verify batch and presentation. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE, Premilene, Optilene, Surgipro or SERAPREN are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
Tissue to suture: USP 2/0 gauge (metric EP 3) is the usual choice for medium-tension planes such as skin, fascia, subcutaneous tissue and ligatures; for more delicate microsurgery planes (ophthalmology, neurosurgery) consider 4/0, 5/0 or 6/0 gauges from the same DS 19 family, and for planes of greater mechanical tension, USP 0 gauge.
Needle size: the DS 19 is a short needle, suitable for surgical fields with reduced access and superficial planes; for wider fields or deep tissue, the DS 24 (AMP732DS2430.2), DS 30 (AMP732DS3030.2) or DS 40 (AMP732RDS4030.2) variants are available within the same Premisut Prime system.
Presentation: the 2 × 75 cm version reduces the opening of packages per procedure compared to the single-thread version (AMP732DS1920); if you prefer an economical alternative, the standard quality Premisut (AM732DS1920) maintains the same needle and configuration.
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DS1920.2 and the batch number for traceability in the operating theatre and in case of complaint. For B2B volume conditions, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.