Description
1. Commercial Introduction
The polypropylene suture PREMISUT PRIME is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating tissue with full control. This presentation in USP 2/0 gauge, with a ⅜ circle needle with a grooved reverse cutting triangular point of 30 mm (DS 30 Prime profile) and a blue thread of 75 cm, is indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
It is supplied sterile and ready for the operating theatre in a box of 12 units with batch traceability, facilitating hospital stock management and presentation for public tenders. Available at Cahnos under the factory reference P732DS3020 (SKU AMP732DS3020), maintained without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The DS 30 Prime needle (⅜ circle, grooved reverse cutting triangular point of 30 mm) penetrates soft and poorly distensible tissues with a clean and stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage. The grooved finish of the needle body facilitates smooth delivery during knotting. The identification blue colour guarantees optimal visibility of the thread on the surgical field. Ethylene oxide sterilisation guarantees sterile delivery; single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Line | Premisut Prime (Prime quality, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 2/0 (metric EP 3); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue, grooved (high visibility) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Reverse cutting triangular point, grooved body |
| Needle size | 30 mm (DS 30 Prime profile) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DS3020 |
| Reference Cahnos (SKU) | AMP732DS3020 |
DS family (⅜ circle, reverse cutting triangular point) in USP 2/0 gauge, blue, 75 cm:
| Needle profile | USP | Presentation | Reference |
| DS 30 Prime | 2/0 | 1 × 75 cm | P732DS3020 / AMP732DS3020 (this product) |
| DS 30 Prime | 2/0 | 2 × 75 cm | P732DS3020.2 / AMP732DS3020.2 |
| DS 36 Prime | 2/0 | 1 × 75 cm | P732DS3620 / AMP732DS3620 |
| DS 40 Prime | 2/0 | 1 × 75 cm | P732DS4020 / AMP732DS4020 |
4. Equivalences and Cross-References
The reference P732DS3020 corresponds to the official nomenclature of the Premisut Prime range (DS 30 Prime profile, single 75 cm thread). Cahnos markets the product keeping the factory reference without altering characters: no digit may be added, removed or reordered when ordering or bidding. The DS needle profile (reverse cutting) is interchangeable within the Premisut system itself, varying only the needle size or gauge.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range (Cahnos) | Polypropylene DS 30 Prime, USP 2/0, blue, 75 cm | P732DS3020 / AMP732DS3020 | Direct product reference | Product analysed in this data sheet |
| Premisut Prime range (Cahnos) | Polypropylene DS 30 Prime, USP 2/0, blue, 2 × 75 cm | P732DS3020.2 / AMP732DS3020.2 | Configuration equivalent within the same system | Same DS 30 needle and USP 2/0 gauge; the presentation changes to 2 threads of 75 cm |
| Premisut range (Cahnos) | Polypropylene DS 30, USP 2/0, blue, 75 cm (standard) | 732DS3020 / AM732DS3020 | Configuration equivalent within the same system | Same DS 30 needle and gauge; standard quality versus Prime (non-grooved needle) |
| Premisut Prime range (Cahnos) | Polypropylene DS 30 Prime, USP 3/0 and 4/0, blue, 75 cm | P732DS3030 / AMP732DS3030 · P732DS3040 / AMP732DS3040 | Comparable within the same system | Same DS 30 needle; the USP gauge changes (3/0 and 4/0) |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 2/0, 75 cm, FSLX 3/8 circle reverse cutting needle | 8689H | Comparable by category, NOT interchangeable 1:1 without clinical validation | Code verified in authorised distribution sources: matches in material, gauge (2/0), colour, thread length (75 cm) and 3/8 reverse cutting needle geometry, but the FSLX needle measures 36 mm versus the 30 mm of the DS 30 Prime profile. Commercial presentation in a box of 36 units; confirm IFU and CE/MDR traceability |
| B. Braun | Premilene® – blue polypropylene monofilament, USP 2/0 (3), 75 cm | C2095442 (HR26S) | Comparable by category – not interchangeable 1:1 | Code verified in regulatory database (GUDID): same material, gauge and length, but needle geometry of ½ circle (HR26S, 26 mm) versus the 3/8 circle with reverse cutting DS30 |
| Medtronic (Covidien) | Surgipro™ II – polypropylene (copolymer with polyethylene), USP 2/0, blue, 75 cm | SP685 (C-15 needle) | Comparable by category – not interchangeable 1:1 | Same gauge, colour and length, but C-15 reverse cutting needle of 26 mm versus DS30 of 30 mm and copolymer material with polyethylene |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | Consult code according to gauge and needle | Comparable by category – pending confirmation | Non-absorbable blue polypropylene monofilament; verify gauge, geometry and needle size with the distributor before substituting |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or substitution. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
- Tissue to suture: the DS reverse cutting grooved needle is suitable for soft and flat tissues requiring firm, controlled penetration (skin, fascia, subcutaneous tissue, cardiovascular surgery, ophthalmology and neurosurgery). For lax or vascular tissues, consider conical point profiles (HR) from the same Premisut Prime range.
- Gauge: USP 2/0 (metric 3) offers a balance between strength and fineness for soft tissues under medium tension; with the same DS 30 needle, versions 3/0 (AMP732DS3030) and 4/0 (AMP732DS3040) are available for more delicate planes, and USP 0/1 for higher tension.
- Needle size: the 30 mm DS is an intermediate needle, ideal for medium suture planes and areas with limited access; for larger fields, DS 36 (AMP732DS3620) and DS 40 (AMP732DS4020) are available in the same 2/0 gauge, and for precision plastic surgery, the square-bodied XDS range (AMP732XDS3020).
- Presentation: the double version 2 × 75 cm (AMP732DS3020.2) reduces the number of packages opened per procedure, practical for continuous or multiple-pass sutures; the standard version AM732DS3020 is the economical alternative with the same configuration.
- Sterility verification: sterile product by ethylene oxide, single use and not re-sterilisable; always check the integrity of the blister and the expiry date before each use, and keep the reference P732DS3020 and the batch number for traceability in the operating theatre and in the event of a claim.





Reviews
There are no reviews yet.