Description
1. Commercial Introduction
The polypropylene suture PREMISUT PRIME in double format (2×75 cm) is the reference solution for surgical teams, purchasing centres and tenders that require a reliable non-absorbable monofilament with predictable handling and minimal tissue reaction. Its ⅜ circular 24 mm needle with a grooved reverse cutting triangular point (DS24 profile) and its USP size 3/0 offer an excellent balance between controlled penetration and tensile strength, making it a common choice for soft tissue approximation, ligatures and procedures in cardiovascular surgery, ophthalmology and neurosurgery. Each unit is supplied sterile, ready for immediate use, in a box of 12 individual sachets, ensuring continuous supply for the operating theatre, clinic or consulting room.
2. Technical Explanation
Polypropylene is a synthetic polyolefin extruded in the form of uncoated monofilament. As it lacks interstices and a wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence and minimises tissue trauma. Being non-absorbable, it is not degraded by enzymes: it is gradually encapsulated by fibrous connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase.
The ⅜ circle needle with a reverse cutting triangular point (inverted triangular or reverse cutting according to international nomenclature) penetrates firm, inelastic tissues with a clean, stable cut, minimising the risk of tearing; the grooved body facilitates smooth, controlled passage during suturing and knotting. The blue colour of the thread provides optimal visibility on the surgical field. Product sterilised by ethylene oxide, single-use, not resterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption type | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Thread colour | Identification blue (high visibility) |
| USP size | 3/0 (metric 2) |
| Thread length | 2 × 75 cm (2 threads per unit, double format) |
| Needle shape | ⅜ circle (3/8 circular) |
| Needle type | Grooved reverse cutting triangular point (DS profile) |
| Needle size | DS24 (24 mm) |
| Sterilisation | Ethylene oxide (EO) – sterile, single use, do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Reference Cahnos (SKU) | AMP732DS2430.2 |
| Line reference | P732DS2430 (base format 75 cm; double presentation with suffix .2) |
4. Equivalences and Cross-References
Important: there is no equivalence table validated by the manufacturer that cross-references this product with other brands. The following comparisons are functional, at category level, and not interchangeable 1:1; always confirm them against the technical data sheet and IFU of each manufacturer before using them in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS24, USP 3/0, blue, 75 cm (single thread) | AMP732DS2430 | Direct equivalence within the catalogue (1-thread configuration) | Same DS24 needle, same size 3/0, same colour and material; the number of threads per pack changes (1 vs 2). |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue monofilament polypropylene | EH7694H (USP 3/0, FS-1 needle, 3/8 reverse cutting, 75 cm) | Comparable by category, not interchangeable 1:1 | Matches material, size 3/0, colour and thread length; FS-1 needle of 24 mm with geometry similar to DS24 although with different nomenclature. Verify IFU and presentation (box of 36 units). |
| B. Braun | Optilene® / Premilene® – polypropylene monofilament | Optilene DS24: RCPC3090236 (verified in 2/0; for 3/0 confirm code) · Premilene: C2090341 (USP 3/0) | Comparable by category, pending confirmation of exact code for DS24 in 3/0 | Copolymer material of polypropylene and polyethylene (not pure polypropylene); same indication and DS reverse cutting geometry. Confirm size, needle measurement and packaging in the official catalogue. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene monofilament | Consult 3/0 reference according to needle (CT/PP families) | Comparable by category, not interchangeable 1:1 | Same size, colour and length as intended; copolymer material and reverse cutting needles of measurement to be confirmed against the IFU. |
| Atramat | Polypropylene CE24 (PE-24), 24 mm 3/8 reverse cutting needle | CE2462-75 (verified in size 2/0; for 3/0 confirm) | Comparable by category, not interchangeable 1:1 | Same needle dimensions (24 mm) and curvature; verify Prime quality against conventional version, grooving and presentation. |
Mandatory technical note: the references from other manufacturers cited come from official catalogues or verified authorised distributors; formal substitution requires verifying USP size, needle measurement and geometry, thread length, colour, surface treatment and regulatory classification (CE/MDR) in the alternative manufacturer’s documentation.
5. Selection tips and variants of interest
- Double format 2×75 cm: ideal for high-consumption procedures or when two identical strands are required per pack opening. If the protocol prefers a single thread, request the AMP732DS2430 version (75 cm, same DS24 and size 3/0).
- Other sizes in the same double 2×75 cm configuration: AMP732DS2420.2 (USP 2/0), AMP732DS2410.2 (USP 0) and AMP732DS2401.2 (USP 1), all with DS24 needle and blue colour.
- Precision with square body: if the tissue is firm or the closure requires a longer cutting edge and directional control (plastic/cosmetic surgery profile), consider the XDS 24 mm family: AMP732XDS2430 (3/0, 75 cm, non-grooved).
- Pre-substitution verification: always check curvature (⅜), needle length (24 mm), point type (reverse cutting triangular, not to be confused with conical point), USP size 3/0 and number of threads per pack before approving any change of supplier or reference.
- Sterility and traceability: product sterilised by ethylene oxide and single-use; verify the integrity of the blister and the expiry date before each use and keep the reference and batch number for traceability in the operating theatre.