Polypropylene suture Premisut Prime 3/0 blue – 3/8 circular needle DS 16 mm, reverse cutting triangular point, 75 cm strand (Ref. P732DS1630)

55,00 €

Non-absorbable surgical suture of polypropylene monofilament Premisut Prime with a ⅜ circle needle, 16 mm grooved reverse cutting triangular point (DS16 Prime profile), USP 3/0 gauge (metric 2) and blue 75 cm strand. Uncoated: very smooth tissue passage, minimal trauma and minimal reaction, with gradual encapsulation that maintains wound support for more than three months. Sterilised by ethylene oxide, single-use, presented in a box of 12 units with batch traceability. Indicated for soft tissue approximation, ligatures, cardiovascular surgery, ophthalmology, neurosurgery and general surgery. Factory reference P732DS1630 · SKU Cahnos AMP732DS1630.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP732DS1630

Description

1. Product Presentation

The polypropylene suture Premisut Prime that Cahnos makes available to surgical services, purchasing centres and tenders is the reference choice when a non-absorbable suture with predictable behaviour, excellent handling and minimal tissue reaction is required. This presentation incorporates a ⅜ circle needle with a 16 mm grooved reverse cutting triangular point (DS16 Prime profile), USP 3/0 gauge and a 75 cm strand in high-visibility blue: a fine and precise configuration, widely used in superficial planes, delicate tissues, ligatures and cardiovascular surgery, ophthalmology, neurosurgery and general surgery procedures.

It is supplied sterile, ready for individual use, with batch traceability, facilitating hospital stock management and presentation to public tenders. Available under the factory reference P732DS1630 (SKU Cahnos AMP732DS1630), kept without altering characters: no digit may be added, removed or rearranged when ordering or bidding.

2. Technical Explanation

Polypropylene is a synthetic linear polyolefin (propylene polymer) presented as uncoated monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength over a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.

The DS16 Prime needle (⅜ circle, 16 mm grooved reverse cutting triangular point) penetrates soft and poorly distensible tissues with a clean, stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, reducing the risk of tearing in firm tissues and allowing controlled passage, even in reduced-access planes or microsurgery. The grooved finish of the needle and suture facilitates smooth, consistent delivery during knotting. Sterilised by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

Parameter Specification
Brand / Quality Premisut Prime (premium range, grooved needle)
Thread material Polypropylene monofilament, uncoated, dyed blue
Thread structure Monofilament with grooved surface
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / USP size USP 3/0 (metric 2); conforming to USP and European Pharmacopoeia gauges
Thread diameter 0.200 – 0.249 mm (according to USP Pharmacopoeia, non-absorbable suture)
Thread length 75 cm (1 thread per unit)
Thread colour Identification blue (high visibility in the surgical field)
Needle shape ⅜ circular (3/8 circle)
Needle type Triangular reverse cutting point, grooved (DS profile)
Needle size 16 mm (DS16 Prime profile)
Sterilisation Ethylene oxide (EO) – sterile
Use Single-use, sterile. Do not re-sterilise
Indications Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery
Commercial presentation Sterile individual sachet / box of 12 units; batch traceability
Factory reference P732DS1630
Reference Cahnos (SKU) AMP732DS1630

Gauge equivalence according to USP (indicative):

USP size Metric size Approximate diameter
3/0 2 0.200 – 0.249 mm (non-absorbable suture)

4. Equivalences and Cross-References

The reference P732DS1630 corresponds to the official nomenclature of the Premisut Prime range (DS16 Prime profile, single 75 cm strand, USP 3/0 gauge). Cahnos markets the product maintaining the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®, SERAPREN® or Surgipro™ are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution. It is recommended to consult the technical department of Cahnos to validate any equivalence before use.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Cahnos (Premisut Prime) Polypropylene DS16 Prime, USP 3/0, blue, 75 cm AMP732DS1630 (P732DS1630) Analysed product Reference for this datasheet
Cahnos (Premisut) Polypropylene DS16, USP 3/0, blue, 75 cm (standard) AM732DS1630 Functional category equivalent Same needle, gauge, colour and length; standard quality, needle without grooved body
Cahnos (Premisut Prime) Polypropylene DS16 Prime, USP 4/0, blue, 75 cm AMP732DS1640 Comparable within the system Same DS16 needle and quality; 4/0 gauge for more delicate tissues
Cahnos (Premisut Prime) Polypropylene DS19 Prime, USP 3/0, blue, 75 cm AMP732DS1930 Comparable within the system Same quality and gauge; DS19 needle of 19 mm versus DS16
Cahnos (Premisut Prime) Polypropylene DS36 Prime, USP 3/0, blue, 75 cm AMP732DS3630 Comparable within the system Same gauge and quality; DS36 needle of 36 mm for medium planes
Cahnos (Premisut Prime) Nylon DS16 Prime, 3/0, black, 75 cm AMP642DS1630 Comparable by category, not interchangeable 1:1 Same DS16 needle and gauge; nylon (polyamide) material and black colour
Ethicon (J&J MedTech) PROLENE® – blue polypropylene monofilament 8699G / 8682G / 8649H (depending on needle profile) Comparable by category, not interchangeable 1:1 Codes verified in authorised distribution for gauges 4/0 and 3/0; the P-3/PS-2 needle from the PROLENE series differs in size and geometry from the DS16. Confirm gauge 3/0 and CE/MDR traceability against the IFU
B. Braun Premilene® – blue polypropylene monofilament C2090513 / C2090341 (pending confirmation of 3/0 gauge with DS16) Pending confirmation Same base material; verify in the official catalogue the exact geometry and size of the needle before any substitution
Medtronic / Covidien Surgipro™ II – polypropylene/polyethylene copolymer SP-649 / SP-1634 (depending on gauge) Comparable by category, not verified Copolymer material (not pure polypropylene); different needle geometries and gauges; pending confirmation against the IFU
Serag-Wiessner SERAPREN® – blue polypropylene monofilament Consult official catalogue Pending confirmation Same base material; confirm code, needle and presentation in the official catalogue

5. Selection tips and variants of interest

Tissue to be sutured: the grooved reverse cutting DS needle is suitable for soft tissues and skin planes that require firm, controlled penetration in reduced-access areas (cardiovascular surgery, ophthalmology, neurosurgery and general surgery). For lax or vascular tissues, consider round point (HR) profiles from the same Premisut Prime range.

Needle size: the 16 mm DS16 is a compact needle, ideal for superficial planes, microsurgery and surgical fields with limited space. If the protocol requires a slightly larger needle in the same USP 3/0 gauge, the DS19 (AMP732DS1930) and DS36 (AMP732DS3630) variants from the same Premisut Prime family are available.

Alternative gauges with the same DS16 needle: USP 4/0 (AMP732DS1640) for more delicate tissues, and USP 2/0 or 5/0 within the same DS16 family for greater mechanical demand or precision microsurgery.

Length and presentation: this 75 cm reference offers sufficient margin for secure passes and knots; as an economical alternative, the standard quality Premisut (AM732DS1630) maintains the same needle, gauge and colour. If the protocol prefers nylon suture with an identical needle, consider reference AMP642DS1630 (nylon, 3/0, black).

Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DS1630 and the batch number for traceability in the operating theatre and in case of complaint. For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.

Additional information

Material

Uncoated monofilament polypropylene

Structure

Monofilament with grooved surface

Absorption

Non-absorbable (gradual encapsulation, support > 3 months)

USP size

3/0 (metric 2)

Thread diameter

0.200 – 0.249

Needle type

Reverse cutting triangular, grooved

Needle size

16 mm (DS16 Prime profile)

Sterilisation

Ethylene oxide (EO)

Use

Single-use, sterile, non-resterilisable

Presentation

Box of 12 units

Manufacturer reference

P732DS1630

Indications

Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery

Medida de aguja

DS 16

Usp

3/0

Color

Blue

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Polypropylene suture Premisut Prime 3/0 blue – 3/8 circular needle DS 16 mm, reverse cutting triangular point, 75 cm strand (Ref. P732DS1630)”

Your email address will not be published. Required fields are marked *