Description
1. Commercial Introduction
The polypropylene suture Premisut Prime that we offer at Cahnos is a highly reliable solution for closing and approximating soft tissues. It is a non-absorbable, monofilament, blue suture, with excellent mechanical performance and minimal tissue reaction. Each unit includes a 90 cm thread mounted on a ⅜ circle needle with a 45 mm reverse cutting triangular point (model DS45 Prime), delivered sterile and ready for the operating theatre. The presentation in a box of 12 units, with lot traceability, facilitates hospital purchasing management and submission to tenders.
2. Technical explanation
Polypropylene is a linear synthetic polymer (polyolefin, [C₃H₆]ₙ) that comes as an uncoated monofilament. Being non-absorbable, the thread does not degrade: it becomes gradually encapsulated by the tissue and maintains its tensile strength for more than three months, making it the classic choice for cardiovascular surgery, vascular surgery and long-term sutures. The ⅜ circle needle with reverse cutting triangular point (reverse cutting) and ribbed body penetrates firm, non-distensible tissues with a clean cut, minimising tissue trauma. The blue colour improves visibility and control in the field. Sterilisation by ethylene oxide (EO) guarantees sterile delivery for immediate use; single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / Line | Premisut Prime (Prime quality, grooved needle) |
| Material | Polypropylene, uncoated monofilament, dyed blue |
| Absorption | Non-absorbable; gradual encapsulation, tension support greater than 3 months |
| Gauge | USP 2/0 (metric EP 3). Conforms to USP and European Pharmacopoeia specifications |
| Thread length | 90 cm (1 thread per unit) |
| Thread colour | Identification blue |
| Needle shape | ⅜ circle (3/8 circular) |
| Needle type | Reverse cutting triangular point, grooved body |
| Needle size | 45 mm (model DS45 Prime) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile; do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology, neurosurgery and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Line reference | P733DS4520 |
| Reference Cahnos (SKU) | AMP733DS4520 |
4. Equivalences and Cross-References
Within the Cahnos catalogue itself and the market of non-absorbable polypropylene sutures, the following references are the closest alternatives to the DS45 Prime 2/0 blue 90 cm configuration:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS45, USP 2/0, blue, 2 x 90 cm | AMP733DS4520.2 | Direct equivalent (double presentation) | Same DS45 needle, gauge and material; 2 threads of 90 cm per unit instead of 1. Interchangeable within the Premisut system. |
| Cahnos (Premisut) | Polypropylene 3/8 DS45, USP 2/0, blue, 90 cm | AM733DS4520 | Functional category equivalent | Same geometry and gauge; Premisut standard quality (not Prime), needle without ribbed body. |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS45, USP 0, blue, 90 cm | AMP733DS4510 | Comparable by category | Same DS45 needle and length; USP 0 gauge of larger diameter (metric 3.5). Not interchangeable 1:1 in gauge. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 2/0, 3/8 circle reverse cutting needle 45 mm | NW863 | Comparable by category / pending confirmation | Code verified in authorised distributors: same needle profile (3/8 reverse cutting, 45 mm) and gauge, but thread of 70 cm versus 90 cm. Not interchangeable 1:1 due to thread length. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 2/0, 90 cm | W8571 | Comparable by category | Same gauge and thread length, but straight KS-55 needle of 55 mm versus ⅜ circular of 45 mm. Not interchangeable 1:1. |
| B. Braun | Premilene® – blue polypropylene monofilament | No 1:1 code verified in public sources (C209xxxx line) | Comparable by category / pending confirmation | Official catalogue shows configurations with HR needle (1/2 circle) and other gauges/lengths (e.g. C2090908, 3/0). Check with the manufacturer for availability of DS45 2/0 90 cm. |
| Medtronic / Covidien | Surgipro™ II – polypropylene with polyethylene, 2/0, blue | SP685 | Comparable by category | Code verified: C-15 3/8 circle reverse cutting needle, 75 cm (30″) thread. Copolymer material and shorter length; not interchangeable 1:1. |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | No 1:1 code verified for DS45 2/0 90 cm | Comparable by category / pending confirmation | DS range (⅜ reverse cutting) available in several gauges and lengths; no exact public reference has been found for this configuration. Confirm with the manufacturer. |
Mandatory technical note: there is no official equivalence table validated by the manufacturer that cross-references this product with other brands; comparisons with PROLENE®, Premilene®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
- Tissue and suture plane: the DS45 needle (45 mm, ribbed reverse cutting) is ideal for deep planes, firm or fascial tissues; for more superficial planes consider DS40, DS36 or DS30 from the same Premisut Prime range.
- Gauge: USP 2/0 (metric 3) offers a balance between strength and fineness for tissues under mediana tension. For higher demand, the same DS45 needle is available in USP 0 (AMP733DS4510) or USP 1 (AMP733DS4501).
- Presentation: if the protocol requires multiple passes or long sutures, the double presentation AMP733DS4520.2 (2 x 90 cm) reduces the opening of packages per procedure.
- Prime quality: needle with ribbed body, improved penetration and less tissue trauma compared to the standard Premisut line (AM733DS4520).
- Verification before use: check the integrity of the blister and the expiry date; keep the reference P733DS4520 and the batch number for traceability in the operating theatre and in case of a complaint.





Reviews